Danfoss-LOGO

Danfoss 130B1272 Ampidiro MCB 114 VLT Sensor

Danfoss-130B1272-Input-MCB-114-VLT-Sensor-PRODUCT

Fampahafantarana ny vokatra

The VLT® Sensor Input MCB 114 can be used in the following cases:

  • Fampidirana sensor ho an'ny mpandefa mari-pana PT100 sy PT1000 ho an'ny fanaraha-maso ny mari-pana.
  • As general extension of analog inputs with 1 extra input (0/4–20 mA) for multi-zone control or differential pressure measurements.
  • Support extended PID controllers with I/Os for setpoint, transmitter/sensor inputs.
Série FC Version software
VLT® HVAC Drive FC 102 1.00 sy aoriana
VLT® AQUA Drive FC 202 1.41 sy aoriana
VLT® Automation Drive FC 301/FC 302 6.02 sy aoriana

Tabilao 1.1 Software Versions Supporting the VLT® Sensor Input MCB 114

Zavatra atolotra

Ny entana omena dia miankina amin'ny laharan-kaody voabaiko sy ny karazana fefy amin'ny mpanova matetika.

Laharan-kaody Zavatra omena
130B1172 Uncoated version
130B1272 Version coated

Danfoss-130B1272-Input-MCB-114-VLT-Sensor-fig (1)

Information momba ny fiarovana

FAMPITANDREMANA

FOTOANA FOTOANA

Ny mpanova matetika dia misy capacitors DC-rohy, izay afaka mijanona ho voampanga na dia tsy mandeha aza ny mpanova matetika. High voltage dia mety ho eo na dia eo aza ny jiro famantarana LED fampitandremana o. Mety hiteraka fahafatesana na ratra mafy ny tsy fiandrasana ny fotoana voatondro aorian'ny fanesorana ny herinaratra alohan'ny hanaovana asa fanompoana na fanamboarana.

  • Atsaharo ny motera.
  • Tapaho ny famatsian-jiro AC sy famatsiana herinaratra DC-rohy lavitra, ao anatin'izany ny famerenan'ny bateria, ny UPS, ary ny fifandraisana DC amin'ny mpanova matetika hafa.
  • Tapaho na hidio ny motera PM.
  • Wait for the capacitors to discharge fully. The minimum duration of waiting time is specified in Tables 1.2 to Table 1.4.
  • Alohan'ny hanaovana asa fanompoana na fanamboarana dia ampiasao ny voltage fitaovana fandrefesana mba hahazoana antoka fa ny capacitors dia esorina tanteraka.

famaritana

BOKYtage [V] Fotoana fiandrasana farafahakeliny (minitra)
4 7 15 20 30 40
200–240 1.1–3.7 kW

(1.50–5 hp)

5.5–45 kW

(7.5–60 hp)

380–480 1.1–7.5 kW

(1.50–10 hp)

11–90 kW

(15–121 hp)

315–1000 kW

(450–1350 hp)

400 90–315 kW

(121–450 hp)

500 110–355 kW

(150–500 hp)

525 75–315 kW

(100–450 hp)

525–600 1.1–7.5 kW

(1.50–10 hp)

11–90 kW

(15–121 hp)

690 90–315 kW

(100–350 hp)

525–690 1.1–7.5 kW

(1.50–10 hp)

11–90 kW

(15–121 hp)

400–1400 kW

(500–1550 hp)

450–1400 kW

(600–1550 hp)

Tabilao 1.2 Discharge Time, VLT® HVAC Drive FC 102

BOKYtage [V] Fotoana fiandrasana farafahakeliny (minitra)
4 7 15 20 30 40
200–240 0.25–3.7 kW

(0.34–5 hp)

5.5–45 kW

(7.5–60 hp)

380–480 0.37–7.5 kW

(0.5–10 hp)

11–90 kW

(15–121 hp)

110–315 kW

(150–450 hp)

315–1000 kW

(450–1350 hp)

355–560 kW

(500–750 hp)

525–600 0.75–7.5 kW

(1–10 hp)

11–90 kW

(15–121 hp)

400–1400 kW

(400–1550 hp)

525–690 1.1–7.5 kW

(1.5–10 hp)

11–90 kW

(10–100 hp)

75–400 kW

(75–400 hp)

450–800 kW

(450–950 hp)

Tabilao 1.3 Discharge Time, VLT® AQUA Drive FC 202

BOKYtage [V] Fotoana fiandrasana farafahakeliny (minitra)
  4 7 15 20 30 40
200–240 0.25–3.7 kW

(0.34–5 hp)

5.5–37 kW

(7.5–50 hp)

     
380–500 0.25–7.5 kW

(0.34–10 hp)

11–75 kW

(15–100 hp)

90–200 kW

(150–350 hp)

250–500 kW

(450–750 hp)

250–800 kW

(450–1350 hp)

315–500

(500–750 hp)

400 90–315 kW

(125–450 hp)

500 110–355 kW

(150–450 hp)

525 55–315 kW

(75–400 hp)

525–600 0.75–7.5 kW

(1–10 hp)

11–75 kW

(15–100 hp)

525–690 1.5–7.5 kW

(2–10 hp)

11–75 kW

(15–100 hp)

37–315 kW

(50–450 hp)

355–1200 kW

(450–1550 hp)

355–2000 kW

(450–2050 hp)

355–710 kW

(400–950 hp)

690 55–315 kW

(75–400 hp)

  • Tabilao 1.4 Ora fandroahana, VLT® Automation Drive FC 301/FC 302

fitomboan'ny

Ny fomba fametrahana dia miankina amin'ny haben'ny fefy amin'ny mpanova matetika.

Enclosure sizes A2, A3, and B3

  1. Remove the LCP (local control panel), the terminal cover, and the LCP frame from the frequency converter.
  2. Ampifandraiso amin'ny slot B ny safidy.
  3. Connect the control cables and relieve the cable. See Illustration 1.4 and Illustration 1.5 for details about wiring.
  4. Remove the knockout in the extended LCP frame (supplied).
  5. Fit the extended LCP frame and terminal cover on the frequency converter.
  6. Ampifandraiso amin'ny rafitra LCP miitatra ny LCP na sarony jamba.
  7. Ampifandraiso amin'ny mpanova matetika ny hery.
  8. Apetraho ao amin'ny masontsivana mifanaraka amin'izany ny fiasan'ny fampidirana/famoahana.

INSTALATION

Sary 1.2 Installation in Enclosure Sizes A2, A3, and B3

Danfoss-130B1272-Input-MCB-114-VLT-Sensor-fig (2)

1 LCP
2 Fonon'ny terminal
3 Slot B
4 SAFIDY
5 LCP frame

Enclosure sizes A5, B1, B2, B4, C1, C2, C3, C4, D, E, and F

  1. Remove the LCP (local control panel) and the LCP cradle.
  2. Ampifandraiso amin'ny slot B ny karatra safidy.
  3. Connect the control cables and relieve the cable. See Illustration 1.4 and Illustration 1.5 for details about wiring.
  4. Fit the cradle on the frequency converter.
  5. Ampifandraiso amin'ny fatorana ny LCP.

Danfoss-130B1272-Input-MCB-114-VLT-Sensor-fig (3)

1 LCP
2 Vidin'ny LCP
3 SAFIDY
4 Slot B

Sary 1.3 Fametrahana amin'ny habe hafa (Eksample)

Insulation galvanika

Atsaharo amin'ny galvanika ny sensor avy amin'ny mains voltage niveau. Fitakiana fiarovana: IEC 61800-5-1 sy UL 508C.

Wiring

Wiring ny VLT® Sensor Input MCB 114.Danfoss-130B1272-Input-MCB-114-VLT-Sensor-fig (4) Danfoss-130B1272-Input-MCB-114-VLT-Sensor-fig (5)

Terminus Anarana asa
1 VDD 24 V DC to supply 0/4–20 mA sensor
2 I in 0/4–20 mA input
3 GND Analog input GND
4, 7, 10 Temp 1, 2, 3 Fampidirana maripana
5, 8, 11 Wire 1, 2, 3 3rd wire input if 3 wire sensors are used
6, 9, 12 GND Temperature input GND

Cabling

Ny halavan'ny tariby famantarana ambony indrindra dia 500 m (1640 ft).

Famaritana elektrika sy mekanika

Ny safidy dia afaka manome ny analogue sensor amin'ny 24 V DC (terminal 1).

Isan'ny fampidirana analogue 1
endrika 0–20 mA na 4–20 mA
Wires 2 tariby
Impedance fampidirana <200 Ω
Sample taha 1 kHz
3rd order filter 100 Hz at 3 dB

Tabilao 1.6 Fampidirana analog

Number of analog inputs supporting

PT100/1000

3
Karazana famantarana PT100/PT1000
fifandraisana PT100 2 or 3 wire

PT1000 2 or 3 wire

Frequency PT100 and PT1000 input 1 Hz for each channel
vahaolana 10 bit
Temperature range -50 hatramin'ny +204 °C

-58 hatramin'ny +399 °F

Tabilao 1.7 Temperature Sensor Input

fanahafana

  • The 3 sensor inputs support 2 and 3 wire sensors and an auto detection of sensor type, PT100 or PT1000 takes places at power-up.
  • The analog input is capable of handling 0/4–20 mA.

For programming of the parameters, see the product-specific programming guide, parameter group 35-** Sensor Input Option and parameter group 18-3* Analog Readouts with data readouts in parameter 18-36 Analog Input X48/2 [mA] to
parameter 18-39 Temp. Input X48/10.

FANAMPIM-PANAZAVANA

Ny Danfoss dia tsy afaka mandray andraikitra amin'ny mety ho lesoka ao amin'ny katalaogy, bokikely ary zavatra vita pirinty hafa. Ny Danfoss dia manana zo hanova ny vokatra tsy misy fampandrenesana. Izany koa dia mihatra amin'ny vokatra efa ao amin'ny kaomandy raha toa ka azo atao ny fanovana toy izany raha tsy mila fanovana manaraka eo amin'ny fepetra efa nifanarahana. Ny marika rehetra ato amin'ity fitaovana ity dia fananan'ny orinasa tsirairay avy. Danfoss sy ny logotype Danfoss dia marika famantarana ny Danfoss A/S. Zo rehetra voatokana.

FAQs

  • F: Inona no tokony hataoko raha maty ny jiro famantarana LED fampitandremana fa mety mbola misy voltage present?
    •  A: Always wait for the specified minimum waiting time after removing power before performing any service or repair work. Use an appropriate voltage measuring device to ensure capacitors are fully discharged.

Documents / Loharano

Danfoss 130B1272 Ampidiro MCB 114 VLT Sensor [pdf] Torolàlana fametrahana
MI38T202, 130B1272 MCB 114 VLT Sensor, 130B1272, MCB 114 VLT Sensor, MCB 114 VLT Sensor, 114 VLT Sensor, VLT Sensor, Sensor

References

Mametraha hevitra

Tsy havoaka ny adiresy mailakao. Voamarika ireo saha ilaina *