dynamic BIOSENSORS AS-2-Rc Fully Automated Laboratory Analysis System
Zvinotsanangurwa
- Product Name: heliX+ ADAPTER STRAND 2 ine dhayi dzvuku Rc
- MugadziriNhoroondo: Dynamic Biosensors GmbH & Inc.
- ModelAS-2-Rc v5.1
- Zvinokosha:
- 2 mavara ane maviri akasiyana anchor sequences eDNA-encoded kero.
- Order Number: AS-2-Rc
- Concentration: 400 nM
- Kuchengeta: White cap, ndapota ona zuva rekupera palabel. Dzivisa akawanda echando-thaw kutenderera nekubvisa nanolever.
Mirayiridzo Yekushandiswa Kwechigadzirwa
Kugadzirira | MIX&RUN
- Sanganisa Adapter strand 1 - Rc (400 nM) uye conjugated Ligand strand ine ligand 1 (500 nM) pa1: 1 chiyero (v / v).
- Sanganisa Adapter strand 2 - Rc (400 nM) uye conjugated Ligand strand ine ligand 2 (500 nM) pa1: 1 chiyero (v / v).
- Isa zvakaparadzana zvigadziriso zviviri zvenhanho 1 uye 2 patembiricha yekamuri pa600 rpm kwemaminetsi makumi matatu kuve nechokwadi chekusanganiswa kwakazara.
- Sanganisa mhinduro dzedanho 1 ne2 pachiyero che1:1 (v/v). Solution yakagadzirira biochip functionalization.
Key Features
- Adapter strand 2 yekushanda kweheliX® Adapter Chip Spot 2.
- Inoenderana neheliX® Adapter Chip.
- Inosanganisira tambo dzeAdapter ye50 regeneration.
- Yakanakira MIX&RUN sample kugadzirira.
- Adapter strand 2 inotakura hydrophobic dhayi tsvuku (Rc) ine neutral net charge.
heliX® Adapter Chip Pamusoroview
2 mavara ane maviri akasiyana anchor sequences eDNA-encoded kero.
Product Description
Order Number: AS-2-Rc
Tafura 1. Zviri mukati uye Kuchengetedza Ruzivo
- Yekushandisa tsvakurudzo chete.
- Chigadzirwa ichi chine hupenyu hushoma hwesherufu, ndapota ona zuva rekupera palabel.
- Kuti udzivise mazai echando echando ndapota aliquot the nanolever
Kugadzirira | MIX&RUN
In-solution hybridization yeadapter uye ligand tambo:
- Sanganisa Adapter strand 1 - Rc (400 nM) uye conjugated Ligand strand ine ligand 1 (500 nM) pa1: 1 chiyero (v / v).
- Sanganisa Adapter strand 2 - Rc (400 nM) uye conjugated Ligand strand ine ligand 2 (500 nM) pa1: 1 chiyero (v / v).
- Isa zvakaparadzana zvigadziriso zviviri zvedanho 1 uye 2 paRT pa600 rpm kwemaminetsi makumi matatu kuti uve nechokwadi chekusanganiswa kwakazara.
- Sanganisa mhinduro yedanho 1 uye 2 pachiyero che1: 1 (v/v). Solution yakagadzirira kushandisa biochip functionalization. Kugadzikana kwemhinduro kunoenderana nekugadzikana kwe ligand molecules.
Tafura 2. Yekuwedzera zvinhu zvekushanda kwenzvimbo 1 uye referenzi nzvimbo 2.
Example
Inodiwa vhoriyamu ye3 functionalizations: 100 μL ine yekupedzisira ye100 nM.
Mushure menguva yekuisa, sanganisa vial 1 uye vial 2 kuti uwane 100 μL yeyakagadzirira kushandisa DNA mhinduro.
Contact
Dynamic Biosensors GmbH Perchtinger Str. 8/10 81379 Munich Germany
Nhoroondo ye Dynamic Biosensors, Inc.
300 Trade Center, Suite 1400 Woburn, MA 01801 USA
- Order Information order@dynamic-biosensors.com
- Technical Support support@dynamic-biosensors.com
- www.dynamic-biosensors.com
Zviridzwa nemachipisi zvinogadzirwa uye zvinogadzirwa muGermany.
©2024 Dynamic Biosensors GmbH | Dynamic Biosensors, Inc. Kodzero dzese dzakachengetwa.
- TE40: 10 mM Tris, 40 mM NaCl, 0.05 % Tween20, 50 μM EDTA, 50 μM EGTA
- Kana puroteni isina kugadzikana muPE40 (TE40, HE40), tapota tarisa kuenderana kwebuffer ne switchSENSE® kuenderana sheet.
FAQ
Mubvunzo: Ndeipi hupenyu hwesherufu yechigadzirwa?
A: Chigadzirwa chine hupenyu hushoma hwesherufu, ndapota tarisa kune zuva rekupera kweiyo label.
Mubvunzo: Ndinofanira kuchengeta sei chigadzirwa kuchengetedza kugadzikana?
A: Chengetedza chigadzirwa nechivharo chichena kuti urege kuonekwa kune chiedza. Dzivisa kutonhora-kutenderera kutenderera nekubvisa nanolever.
Mubvunzo: Ndinofanira kugadzirira sei mhinduro yebiochip functionalization?
A: Tevera matanho ekugadzirira MIX & RUN anopiwa mubhuku rekushandisa kugadzirira mhinduro ye biochip functionalization.
Zvinyorwa / Zvishandiso
![]() |
dynamic BIOSENSORS AS-2-Rc Fully Automated Laboratory Analysis System [pdf] User Manual AS-2-Rc, AS-2-Rc Fully Automated Laboratory Analysis System, Fully Automated Laboratory Analysis System, Automated Laboratory Analysis System, Laboratory Analysis System, Analysis System, System |