ACTIVESHOP Sillon Classic 3 Electric Cosmetic Chair
User Manual
Introduction
This manual provides detailed information on the operation and maintenance of the Sillon Classic 3 electric cosmetic chair. Please read the accompanying instructions carefully before use. Use the device as described. Save this manual and ensure all persons who may use the device are familiar with it.
The Sillon Classic 3 electric cosmetic chair is professional equipment ideally suited for any beauty salon. It is perfect for massage, cosmetic, and podology procedures, as well as physiotherapy. The chair is designed to provide complete comfort during treatment. The chair consists of four parts and a removable cushion. On both sides of the seat, there are handles for attaching the remote control, keeping it readily accessible.
Product Specifications & Load Capacity
Load Capacity: 150 kg
The maximum load capacity of the seat is 150 kg. Do not lift more weight than the chair can withstand. Do not lean on the backrest or apply excessive pressure to the armrests to prevent damage to the product.
Maximum Weight: 40 kg (This likely refers to specific component limits, e.g., footrest, though not explicitly stated in context).
Dimensions:
- Overall Length: 185 cm
- Seat Width: 56 cm
- Seat Depth: 58 cm
- Backrest Width: 36 cm
- Backrest Height: 29 cm
- Headrest Width: 49 cm
- Headrest Depth: 18 cm
- Armrest Width: 12 cm
- Armrest Length: 29 cm
- Footrest Width: 33 cm
- Footrest Length: 26 cm
- Footrest Extension: 16 cm
- Base Width: 52 cm
- Adjustable Height: Min 61 cm, Max 84 cm
Chair Construction Components:
- Headrest (Pagalvis)
- Cushion (Spilvens)
- Backrest (Atzveltne)
- Armrest (Roku balsts)
- Seat (Sēdeklis)
- Footrest (Kāju balsts)
- Footrest Adjustment Mechanism (Kāju balsta regulēšanas mehānisms)
- Cylinder (Cilindrs)
- Plastic Base (Plastmasas pamatne)
Packaging and Initial Setup
The chair is packed in cardboard boxes with 10 paper layers for protection. It is recommended to keep the original packaging for future use, especially for warranty returns. For safety reasons, lifting the chair from the box requires two people. When lifting, stand on both sides of the headrest and footrest ends of the chair. The chair can only be lifted from the headrest and footrest positions, not from the armrest sides.
Before using the chair, check that the packaging is intact and undamaged during transport. If there are any issues, notify the transport company or after-sales service personnel within 2 days of receiving the device. Ensure all accessories are complete upon delivery. If accessories are missing, contact after-sales service staff promptly.
The electric cosmetic chair should be used in closed, dry rooms. The room temperature should be between +10°C and 40°C, with relative humidity between 30% and 75%. If the chair has been exposed to temperatures below 0°C, wait at least 5 hours for the device to reach room temperature before use.
Steps for Use:
- Ensure all packaging materials are removed.
- Verify the chair is in working order.
- Position the chair where it will be used.
- Plug the power cord into a suitable socket.
Note: This device must not be used by children or inexperienced persons. Children should be supervised and must not play near the electric cosmetic chair. For safety, unplug the device and do not leave it unattended. Always disconnect the power cord.
Operation and Features
Power Connection: Connect the power cord to an external power source (110 V ~ 240 V).
Armrest Installation Method: The seat must be in a horizontal position to attach the armrests. Insert the armrest into the opening on the side of the backrest. The armrest must be firmly attached. Rotate it left or right to ensure correct placement. Repeat for the other armrest. The armrest should be perpendicular to the ground (regardless of seat angle) and can be rotated 180°.
Manual Control Functions:
- Height Adjustment: The chair height can be adjusted from 58 cm to 82 cm from the ground. (Controlled by buttons A/B on the remote panel).
- Backrest and Footrest Adjustment: The backrest angle can be adjusted from 0° to 80°, and the footrest angle from 0° to 90°. (Controlled by buttons C/D on the remote panel).
- Footrest Retraction: The footrest can be retracted or extended by 0~12 cm.
Each footrest is individually adjustable, allowing independent positioning. The footrest angle is manually adjustable. The mechanism allows the footrest to tilt sideways, making the chair ideal for podiatry treatments.
Footrest Side Tilt Mechanism: To lift the footrest, pull the lever handle upwards. To tilt the footrest sideways, pull the wheel on the tilting mechanism downwards.
Swing Function: The chair seat can be tilted to an angle, creating a 'swing' or 'cradle' effect. When the backrest is lowered and the footrest is raised, a flat surface is formed.
Cleaning and Disinfection
General Cleaning:
- Before cleaning, unplug the device from the power supply.
- To maintain the chair's surface in good condition, it should be cleaned regularly. Clean and disinfect the chair after each use. Thorough disinfection is recommended monthly.
Surface Cleaning Guidelines:
- Metal and Plastic Surfaces: Wipe with a damp cloth. A small brush is useful for cleaning hard-to-reach areas or corners. Do not use excessive liquid. Disinfect afterwards with an appropriate liquid.
- Stainless Steel Surfaces: Cleaning with a mild detergent solution works best. Ammonia can be used for stubborn stains, along with most solvents. Avoid chlorine-based solutions.
- Painted or Chrome Metal Surfaces: Do not use water jets (showers, high-pressure water cleaners). Do not clean the device at high temperatures or high humidity, nor expose it to conditions that could cause liquid contamination. Do not use solvents or acids for cleaning.
- Upholstery (Leather/Vinyl): Evenly wipe the seat surface with a special leather cleaner, then wipe with a clean, soft cloth.
Maintenance
General Maintenance:
- Before maintenance, unplug the device from the mains.
- Repairs should only be carried out by experienced and authorized personnel. Unauthorized repairs may cause damage to the device, for which the manufacturer is not responsible.
- Use only manufacturer-approved original spare parts.
- Do not use the electric cosmetic chair or accessories if they are not functioning correctly.
- All maintenance and repair work must be documented.
Technical Maintenance Checks:
Check the controls and their cords weekly. At least every six months, check the condition and operation of the following components:
- Power cord and its fastening.
- Motor cords.
- Control unit and its cords.
- Attached accessories.
- Proper functioning of the locking systems.
If any defects are found, stop using the equipment and contact an authorized service center. Only experienced or authorized personnel can open or replace the drive/control unit. If any part of the device is damaged, disconnect the power cable and stop using the device. Then, report it to the service center.
Troubleshooting
Problem | Solution Methods |
---|---|
Manual control unresponsive | Check if the manual control line connection interface is loose (check for electrical circuit issues). Remember to note the initial position of the plug. |
Motor unresponsive | Switch the motor plug position. |
To replace the control unit or order spare parts, contact the service department. Before contacting, describe the problem, including:
- Model:
- Date of purchase:
Safety Precautions
General Safety:
- The device is professional equipment intended for use in beauty salons. Use by qualified cosmetic personnel helps avoid adverse effects during procedures.
- Do not disassemble the device or attempt to use it for purposes other than those specified in this manual. All maintenance and repair work must be performed only by an authorized service technician (ACTIVESHOP Ltd. company).
- Do not install or use the device near liquids, in wet areas, or with wet hands to prevent liquids from entering the device.
- In such cases, immediately unplug the device from the socket and contact the authorized ACTIVESHOP service: (a) if liquid has entered the device, (b) if an unusual smell, smoke, or strange noises are emitted from the device, (c) if the power cord is damaged, or (d) if the device has been overturned or its casing is damaged.
- Do not place any objects on the cables. Do not install the device in places where someone might step on the power cable.
- For safety, always unplug the power cord from the socket when you have finished working with the device.
- Do not insert anything into the device's openings. If a foreign object enters an opening, unplug the cable from the socket and contact the distributor or manufacturer.
- Do not place the device on an unstable trolley, shelf, or vehicle. The device may be damaged if it falls.
- To ensure the device's longevity, it is recommended to observe a one-minute interval before pressing the power button again (between switching on and off, and vice versa).
- The power supply must comply with the specifications indicated on the nameplate. Otherwise, there is a risk of incorrect operation, device damage, or even fire.
Important Warnings:
- If the power cord is damaged or other operational malfunctions occur, contact the authorized service center to avoid any danger.
- This device may be used by children aged 8 years and above, and by persons with limited physical and mental abilities, as well as persons with insufficient experience and knowledge of the equipment, provided that supervision or instruction on safe use is provided, so that they understand the associated risks.
- The equipment is not intended for children to play with. Do not allow children to play with the device.
- Do not leave the device unattended if children or persons without sufficient knowledge of the device's use are nearby.
- This electrical device is not a toy. Improper use or contact with the electrical device can pose a risk to health or cause death, so the device must be used and stored in a place inaccessible to children.
Disposal
Dispose of used electrical devices, accessories, and packaging at recycling centers in accordance with environmental protection principles. Do not dispose of electrical devices in household waste containers. Follow regulations for the disposal of such equipment. To protect the environment, in accordance with Directive 2012/19/EK on waste electrical and electronic equipment, used electrical equipment must be collected separately and then handed over to collection points for electronic and electrical equipment waste. Used and old devices contain fully recyclable components, so they must be handed over for recycling. Therefore, they must be handed over to the appropriate collection points, as well as ACTIVESHOP Ltd.
Storage and Transport
The device must be transported at temperatures from -20°C to +50°C only in its original packaging. Store the device in a well-ventilated room where the relative humidity does not exceed 75%. Operating temperature is from +10°C to +40°C. During storage and transport, the device must not be thrown or dropped, subjected to mechanical impacts, or atmospheric influences.
External Link: www.activeshop.com.pl