Activeshop Sillon Classic 3 Motors Electric Cosmetic Chair
Model: C501A
This manual contains detailed information on the operation and maintenance of the device. Before using the device, read the enclosed manual. Use the device as described. Keep this manual and make sure that all persons who may use the device are familiar with it.
The Sillon electric cosmetic chair is professional equipment ideal for beauty salons, massages, cosmetic, and physiotherapeutic treatments. It is designed for full comfort during treatments and consists of four parts and a removable cushion. Handles on the sides of the seat allow for convenient placement of the control remote.
Load Capacity: 150 kg
The maximum load capacity of the seat body is 150 kg. Do not exceed this weight. Avoid jumping on the backrest or applying excessive pressure on the armrests to prevent damage to the product structure.
Note on Packaging: Cardboard and outer cartons with 10 layers of paper are used for packaging. It is recommended to keep the original packaging for future use, especially for returns. For safety, two people are required to lift the chair out of the carton, lifting from the headrest and footrest positions only.
Before using the chair, check the package for damage during transport. Notify the transportation company if any issues are found.
Operating Conditions:
The electric beauty chair must be used in a closed, dry room with temperatures between +10°C and +40°C, and relative humidity between 30% and 75%. If exposed to temperatures below 0°C, allow at least 5 hours for the device to reach room temperature before use.
Before First Use:
- Ensure all packaging materials are removed.
- Verify the chair is in working order.
- Place the chair in the intended area.
- Plug the power cord into a suitable outlet.
Tip: Children and inexperienced persons should not use this device without supervision. Unplug the device when unattended.
Dimensions of the Device:
Overall length: 185 cm. Width adjustments: +15 cm and +12 cm. Height: 55 cm.
Detailed dimensions are provided, showing various measurements such as seat width (56 cm), backrest height (58 cm), armrest dimensions (52 cm length, 18 cm width), and footrest dimensions (49 cm length, 33 cm width).
Construction of the Device:
- Headrest
- Cushion
- Backrest
- Armrest
- Seat
- Footrest
- Lifting actuator
- Plastic base
Warning:
- The footrest is not designed to support the full weight of an adult.
- Do not sit directly on the armrests or footrest.
- Do not use the chair near flammable gases.
- Do not exceed the chair's weight capacity.
- Ensure outlet distance does not exceed 2 meters.
Note on Power Cord:
- Always plug into a grounded outlet.
- Do not tie or pull the power cord, as this may cause damage. Ensure it can be easily removed in an emergency.
- Remove the power cord before moving the chair to prevent entanglement.
- If the power cord is damaged, disconnect immediately and contact an authorized service center. Use only the original power cord.
- Do not allow untrained persons to operate the remote control.
- Do not place objects under the chair.
- Ensure sufficient clearance for folding and unfolding.
- Keep the area around the chair free of sharp or harmful objects.
- Do not modify the device. Contact a service center if the chair malfunctions.
Use of the Device:
Connect the power cord to an external power supply (110V~240V).
Armrest Installation Method:
With the seat in a horizontal position, slide the armrest into the hole on the side of the backrest until firmly attached. Twist to secure. The armrest is perpendicular to the ground and can be rotated 180°.
Manual Control Functions:
- Lifting Height: The bed can be adjusted from 58 cm to 82 cm from the ground using controls A and B.
- Back and Leg Lift: The backrest can be lifted from 0-80°, and the leg rest from 0-90° using controls C, D, E, and F.
- Retractable Footrest: The footrest can be extended or retracted by 0-12 cm.
Cleaning and Disinfection:
- Unplug the device before cleaning.
- Clean and disinfect the chair regularly, especially after each use. A thorough disinfection once a month is recommended.
I. Metal and Plastic Surfaces:
Wipe with a damp cloth. Use a small brush for hard-to-reach areas. Avoid excessive liquid. Disinfect with a suitable liquid.
II. Stainless Steel Surfaces:
Use a mild detergent solution. Ammonia and most solvents can remove tough stains. Avoid chlorine-based solutions.
III. Painted or Chrome-Plated Metal Surfaces:
- Do not use water jets.
- Avoid high temperatures, high humidity, and conditions leading to liquid contamination.
- Do not use solvents or acids.
IV. Chair Surface:
Wipe the seat surface with a special leather cleaner, then with a clean, soft cloth.
Maintenance:
- Unplug the device before maintenance.
- Repairs must be performed by experienced, manufacturer-authorized personnel. Unauthorized repairs may cause injury or damage.
- Use only original, manufacturer-approved spare parts.
- Do not use the chair or accessories if they are not functioning correctly.
- Document all maintenance and repair work.
Maintenance Measures (Check items at least every six months):
- Power cord and attachment
- Motor wiring
- Control box and wiring
- Accessory attachment
- Normal operation of the locking system
If defects are found, stop using the equipment and contact an authorized service center. Only authorized personnel should open or replace the actuator/control unit. If any part is damaged, unplug the power cord, stop use, and notify the service center.
Troubleshooting:
Problem | Solution Methods |
---|---|
Manual control does not respond | Check if the manual control line connection is loose. Inspect the circuit board. Mark the original plug position. |
Motor does not respond | Switch the position of the motor plug. |
To replace the control box or order spare parts, contact the service department and provide the model and date of purchase.
Safety Measures:
- This is professional equipment for beauty parlors. Operation by qualified personnel is recommended.
- Do not disassemble or use the device for purposes other than those stated in this manual. All servicing and repairs must be performed by an authorized technician (ACTIVESHOP Ltd.).
- Do not install or operate near liquids, wet areas, or with wet hands.
- Immediately unplug and contact authorized service if liquid enters the device, if it emits strange odors, smoke, or sounds, if the power cord is damaged, or if the housing is damaged.
- Do not place objects on cables or where the power cord can be stepped on.
- Unplug the power cord after each use.
- Do not insert foreign objects into the device. If this occurs, unplug and contact the distributor/manufacturer. Do not place the device on unstable surfaces.
- To ensure the device's lifespan, maintain a one-minute interval before pressing the power button again after switching it off and on.
- The power supply must comply with the nameplate specifications to avoid incorrect operation, damage, or burning.
Caution:
- In case of damage or malfunction, contact an authorized service center to avoid danger.
- Children aged 8 and above, and individuals with reduced physical/mental capabilities or lack of experience, may use the device under supervision and with proper instruction regarding safe usage and associated risks.
- The equipment is not intended for play. Do not allow children to play with it.
- Do not leave the appliance unsupervised when children or persons unfamiliar with its use are nearby.
- This is an electrical appliance, not a toy. Improper use can pose health risks or be fatal. Use and store out of reach of children.
Disposal of the Device:
Dispose of used electrical appliances, fixtures, and packaging at raw material reprocessing centers according to environmental protection principles. Do not dispose of in household waste containers. Follow regulations for this type of equipment. According to Directive 2012/19/EC, waste electrical equipment should be collected separately and handed over to collection points for reprocessing. Recyclable components should be handed over for reprocessing or to appropriate collection points, including ACTIVESHOP Ltd.
Storage and Transport:
Transport the device in its original packaging within a temperature range of -20°C to +50°C. Store in a well-ventilated area with humidity not exceeding 75%. Operating temperature is +10°C to +40°C. During storage and transport, the device must not be thrown, dropped, or exposed to mechanical shocks or atmospheric agents.