Activeshop Sillon Classic 3 Motors Electric Cosmetic Chair

Model: C501A

This manual contains detailed information on the operation and maintenance of the device. Before using the device, read the enclosed manual. Use the device as described. Keep this manual and make sure that all persons who may use the device are familiar with it.

The Sillon electric cosmetic chair is professional equipment ideal for beauty salons, massages, cosmetic, and physiotherapeutic treatments. It is designed for full comfort during treatments and consists of four parts and a removable cushion. Handles on the sides of the seat allow for convenient placement of the control remote.

Load Capacity: 150 kg

The maximum load capacity of the seat body is 150 kg. Do not exceed this weight. Avoid jumping on the backrest or applying excessive pressure on the armrests to prevent damage to the product structure.

Note on Packaging: Cardboard and outer cartons with 10 layers of paper are used for packaging. It is recommended to keep the original packaging for future use, especially for returns. For safety, two people are required to lift the chair out of the carton, lifting from the headrest and footrest positions only.

Before using the chair, check the package for damage during transport. Notify the transportation company if any issues are found.

Operating Conditions:

The electric beauty chair must be used in a closed, dry room with temperatures between +10°C and +40°C, and relative humidity between 30% and 75%. If exposed to temperatures below 0°C, allow at least 5 hours for the device to reach room temperature before use.

Before First Use:

  1. Ensure all packaging materials are removed.
  2. Verify the chair is in working order.
  3. Place the chair in the intended area.
  4. Plug the power cord into a suitable outlet.

Tip: Children and inexperienced persons should not use this device without supervision. Unplug the device when unattended.

Dimensions of the Device:

Overall length: 185 cm. Width adjustments: +15 cm and +12 cm. Height: 55 cm.

Detailed dimensions are provided, showing various measurements such as seat width (56 cm), backrest height (58 cm), armrest dimensions (52 cm length, 18 cm width), and footrest dimensions (49 cm length, 33 cm width).

Construction of the Device:

Warning:

Note on Power Cord:

Use of the Device:

Connect the power cord to an external power supply (110V~240V).

Armrest Installation Method:

With the seat in a horizontal position, slide the armrest into the hole on the side of the backrest until firmly attached. Twist to secure. The armrest is perpendicular to the ground and can be rotated 180°.

Manual Control Functions:

  1. Lifting Height: The bed can be adjusted from 58 cm to 82 cm from the ground using controls A and B.
  2. Back and Leg Lift: The backrest can be lifted from 0-80°, and the leg rest from 0-90° using controls C, D, E, and F.
  3. Retractable Footrest: The footrest can be extended or retracted by 0-12 cm.

Cleaning and Disinfection:

I. Metal and Plastic Surfaces:

Wipe with a damp cloth. Use a small brush for hard-to-reach areas. Avoid excessive liquid. Disinfect with a suitable liquid.

II. Stainless Steel Surfaces:

Use a mild detergent solution. Ammonia and most solvents can remove tough stains. Avoid chlorine-based solutions.

III. Painted or Chrome-Plated Metal Surfaces:

IV. Chair Surface:

Wipe the seat surface with a special leather cleaner, then with a clean, soft cloth.

Maintenance:

Maintenance Measures (Check items at least every six months):

  1. Power cord and attachment
  2. Motor wiring
  3. Control box and wiring
  4. Accessory attachment
  5. Normal operation of the locking system

If defects are found, stop using the equipment and contact an authorized service center. Only authorized personnel should open or replace the actuator/control unit. If any part is damaged, unplug the power cord, stop use, and notify the service center.

Troubleshooting:

ProblemSolution Methods
Manual control does not respondCheck if the manual control line connection is loose. Inspect the circuit board. Mark the original plug position.
Motor does not respondSwitch the position of the motor plug.

To replace the control box or order spare parts, contact the service department and provide the model and date of purchase.

Safety Measures:

  1. This is professional equipment for beauty parlors. Operation by qualified personnel is recommended.
  2. Do not disassemble or use the device for purposes other than those stated in this manual. All servicing and repairs must be performed by an authorized technician (ACTIVESHOP Ltd.).
  3. Do not install or operate near liquids, wet areas, or with wet hands.
  4. Immediately unplug and contact authorized service if liquid enters the device, if it emits strange odors, smoke, or sounds, if the power cord is damaged, or if the housing is damaged.
  5. Do not place objects on cables or where the power cord can be stepped on.
  6. Unplug the power cord after each use.
  7. Do not insert foreign objects into the device. If this occurs, unplug and contact the distributor/manufacturer. Do not place the device on unstable surfaces.
  8. To ensure the device's lifespan, maintain a one-minute interval before pressing the power button again after switching it off and on.
  9. The power supply must comply with the nameplate specifications to avoid incorrect operation, damage, or burning.

Caution:

Disposal of the Device:

Dispose of used electrical appliances, fixtures, and packaging at raw material reprocessing centers according to environmental protection principles. Do not dispose of in household waste containers. Follow regulations for this type of equipment. According to Directive 2012/19/EC, waste electrical equipment should be collected separately and handed over to collection points for reprocessing. Recyclable components should be handed over for reprocessing or to appropriate collection points, including ACTIVESHOP Ltd.

Storage and Transport:

Transport the device in its original packaging within a temperature range of -20°C to +50°C. Store in a well-ventilated area with humidity not exceeding 75%. Operating temperature is +10°C to +40°C. During storage and transport, the device must not be thrown, dropped, or exposed to mechanical shocks or atmospheric agents.

Models: C501A Electric Cosmetic Chair Sillon Classic 3 Motors, C501A, Electric Cosmetic Chair Sillon Classic 3 Motors, Cosmetic Chair Sillon Classic 3 Motors, Chair Sillon Classic 3 Motors, Sillon Classic 3 Motors, Classic 3 Motors, Motors

File Info : application/pdf, 10 Pages, 441.42KB

PDF preview unavailable. Download the PDF instead.

150220 manual en

References

Aspose.Words for .NET 25.2.0

Related Documents

Preview ACTIVESHOP Sillon Classic C501A Electric Cosmetic Chair Instruction Manual
Comprehensive instruction manual for the ACTIVESHOP Sillon Classic C501A electric cosmetic chair, covering operation, maintenance, safety, troubleshooting, and disposal. Ideal for beauty salons, massages, and cosmetic treatments.
Preview Activeshop Sillon Classic 3 Motors Electric Cosmetic Chair User Manual
User manual for the Activeshop Sillon Classic electric cosmetic chair with 3 motors. Provides instructions on operation, maintenance, safety precautions, and troubleshooting.
Preview ACTIVESHOP Sillon Classic 3 Electric Cosmetic Chair User Manual
Comprehensive user manual for the ACTIVESHOP Sillon Classic 3 electric cosmetic chair, covering operation, safety, maintenance, and troubleshooting for professional salon use. Includes detailed diagrams and safety warnings.
Preview ACTIVESHOP Sillon 210 Cosmetic Chair User Manual and Safety Instructions
Comprehensive user manual and safety guidelines for the ACTIVESHOP Sillon 210 hydraulic cosmetic chair, covering assembly, operation, maintenance, and disposal.
Preview ACTIVESHOP Sillon Classic Electric Cosmetic Chair - Instructions for Use
Detailed instructions for use, maintenance, and safety of the ACTIVESHOP Sillon Classic electric cosmetic chair with 3 motors and cradle. Includes setup, operation, cleaning, troubleshooting, and disposal information.
Preview ACTIVESHOP Sillon Lux 273b Electric Cosmetic Chair User Manual
Detailed user manual for the ACTIVESHOP Sillon Lux 273b electric cosmetic chair with 3 motors. Covers setup, operation, remote control functions, cleaning, maintenance, troubleshooting, safety precautions, and disposal.
Preview ACTIVESHOP Azzurro 708B Electric Cosmetic Chair User Manual
This user manual provides comprehensive instructions for the ACTIVESHOP Azzurro 708B electric cosmetic chair, covering setup, operation, maintenance, safety precautions, and troubleshooting for professional salon use.
Preview Azzurro 708B Electric Cosmetic Chair User Manual
User manual for the Azzurro 708B electric cosmetic chair with 4 motors by ACTIVESHOP. This guide covers setup, operation, features, maintenance, safety precautions, and disposal instructions for professional salon use.