FSP AC-DC Converter A10-XE2 Series
Description
The FSP A10-XE2 Series comprises AC-DC switching power supplies in a compact 40.0 x 33.5 x 22.0 mm package, capable of delivering 10 watts. These converters are designed for industry control applications and AC motor control applications.
Features
- Universal input: 90-264VAC, 47-63Hz
- Operating temperature: -25°C to +85°C
- Encapsulated, compact case
- High efficiency up to 80%
- Fixed output voltage
- Continuous short circuit protection
- Isolated output: 3750VAC
- OVP, short circuit protection
General Specifications
Wattage: 10W
Dimension: 40.0(L) x 33.5(W) x 22.0(H) mm
Safety Standard Approval: Meet 60950 / 60335-1
Environmental Specification:
- Operating temperature: -25°C to +85°C
- Storage temperature: -25°C to +85°C
Selection Guide
Part number | Input voltage | Output voltage | Output current @ full load | Efficiency (typ.) | Capacitive load (max.) |
---|---|---|---|---|---|
A10-XE2-3.3 | 90-264 VAC | 3.3 VDC | 2500 mA | 70% | 18000μF |
A10-XE2-05 | 90-264 VAC | 5 VDC | 2000 mA | 76% | 4800μF |
A10-XE2-12 | 90-264 VAC | 12 VDC | 840 mA | 78% | 2000μF |
A10-XE2-24 | 90-264 VAC | 24 VDC | 420 mA | 80% | 360μF |
1. Typical efficiency measured @115Vac/ 230Vac, full load and +25°C after warm-up time.
2. Capacitive load measure @115Vac with constant resistant mode full load.
3. The product information and specifications are subject to change without prior notice.
4. All specifications valid at nominal input voltage (115/230VAC), full load and 25°C after warm-up time unless otherwise stated.
Detailed Specifications
Parameter | Conditions | Min. | Typ. | Max. | Unit | ||
---|---|---|---|---|---|---|---|
Input | Input voltage range | 90 | 264 | VAC | |||
Input current | 115V | 250 | mA | ||||
230V | 150 | mA | |||||
Input frequency | 90V-264V | 47 | 63 | Hz | |||
No load power consumption | 90V-264V | 0.1 | W | ||||
Inrush current (cold start @25°C) | 115V | 20 | A | ||||
230V | 40 | A | |||||
Start-up time | 115V | 2 | S | ||||
Leakage current | 264V | 0.25 | mA | ||||
Fuse | External | ||||||
Output | Output voltage accuracy | 90V-264V | ±6 | % | |||
Operating frequency | 90V-264V | 75 | KHz | ||||
Ripple & noise (1) | Vo=5V / 12V Vo=3.3V / 24V | 150 180 | mVp-p | ||||
Minimum load | 90V-264V | 0 | % | ||||
Line regulation | 90V-264V | ±1.5 | % | ||||
Load regulation | 90V-264V (10%~100%) | ±2 | % | ||||
Hold-up time | 115V / 60Hz | 8 | ms | ||||
Environment | Operating temperature | -25 | 55 | °C | |||
Storage temperature | -25 | 85 | °C | ||||
Relative Humidity | 95 | %RH | |||||
Vibration | MIL-STD-202G | ||||||
Isolation | Isolation voltage | 1 Minute, Pri to Sec cut-off current: 5mA | 3750 | VAC | |||
Isolation capacitance | 1100 | pF | |||||
Function | Isolation resistance | DC 500V | 1 | GΩ | |||
MTBF | 115 VAC @25°C | TBD | Hours | ||||
Over load protection | Automatic recovery | ||||||
Short circuit protection | Continuous, Automatic recovery | ||||||
Safety Approvals | Meet 60950 / 60335-1 | ||||||
Dimension | (L x W x H) | 40.0x33.5x22.0 mm | |||||
Physical | Weight | 42.0 | g | ||||
EMI | EN 55032 | Class B | |||||
ESD | IEC61000-4-2 | Criteria A | |||||
EFT | IEC61000-4-4 | Criteria A | |||||
Surge | IEC61000-4-5 | Criteria A |
Ripple & Noise and Derating
Ripple & Noise: Test conditions include E-Cap 47uF low ESR and 0.1uF MLCC across outputs at 20MHz bandwidth. All specifications are valid at nominal input voltage, full load, and +25°C after warm-up time unless otherwise stated.
Circuit Description: The circuit includes a slow-blow fuse (1.5A~2A) connected to the input voltage (Vin), with output terminals (+Vout, -Vout) and a ground lead. External capacitors (47uF, 0.1uF) are connected between Vin and Vout.
Derating Curve: The derating curve illustrates load capacity as a percentage of maximum load versus operating temperature (°C). The curve shows that the converter can operate at 120% load at -25°C, decreasing to 100% load at approximately 55°C, and reaching 0% load above 85°C.
Mechanical Specification
Dimensions: The converter has a main body measuring 40.0 mm (Length) x 33.5 mm (Width) x 22.0 mm (Height). The bottom view details the pin assignments and dimensions. The projection method used is third angle projection, with a dimensional tolerance of ±0.25mm.
Pin | Single |
---|---|
1 | Vin (N) |
2 | Vin (L) |
3 | +Vout |
4 | -Vout |
Package Information
Package: The product is supplied in tubes, with each tube containing 14 pieces. The total length of a tube is 520±2mm. The package dimensions are 44±0.5 mm x 33±0.5 mm.