FSP150-P35 Series 150W ITE Power Supplies
Technical Datasheet
Product Overview
The FSP150-P35 Series comprises 150W ITE (Information Technology Equipment) AC-DC switching power supplies designed by FSP Group. These are Class-I PSUs featuring a low profile, compact 3 x 5 inch package, and low no-load power consumption (less than 0.21W).
Image Description: The product is an open-frame power supply unit, showcasing its internal components and connectors on a circuit board.
Key Features
- Class-I design
- Designed to meet IEC 60950-1 and IEC 62368-1 safety standards
- Low profile: 3 x 5 x 1.126 inches
- No load power consumption: less than 0.21W
- EN 55032 Class B radiated emission compliance
- Surge protection: ±2 KV differential, ±4 KV common mode
- High altitude operation: up to 5000 meters
- Includes Over Temperature Protection (OTP) and Brown-out protection
- 12V fan driver
Safety Standard Approval
The power supplies are approved by CE, CB, and are UL recognized.
Technical Specifications
Input Specifications
- Input voltage: 90-264 VAC
- Input frequency: 47-63 Hz
- Input current: 1.7 A (rms) for 115 VAC; 0.8 A (rms) for 230 VAC
- No load power consumption: ≤0.21W
- Earth leakage current: 0.75 mA max. @ 264 VAC, 63 Hz
- Touch current: 0.25 mA max. @ 264 VAC, 63 Hz
Output Specifications
- Fan driver: Non-regulated 12V @ 500 mA max.
- Total output power: 150W
- Protection:
- Over voltage: Set at 110~122% of nominal output voltage, with latch-off protection.
- Short circuit & Over current: Output protected against short circuit conditions with auto-recovery.
- Over temperature: Detected by thermistor and latch off.
- Brown out: Set at 75VAC.
- Temperature coefficient: All outputs ±0.04% /°C maximum.
- Transient response: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 µs after a 25% step load change.
Environmental Specifications
- Operating temperature: -20°C to +70°C
- Storage temperature: -40°C to +85°C
- Relative humidity: 5% to 95% non-condensing
- Derating: Derate from 100% at +50°C linearly to 50% at +70°C, applicable to both convection and forced-air cooling conditions.
General Specifications
- Power factor: 0.98 minimum @ 115VAC & 100% load; 0.9 minimum @ 230VAC & 100% load.
- Power turn-on time: 1.0 Sec maxi.
- Hold-up time: 20 mS minimum at 115 VAC @ 100W; 8 mS minimum at 115VAC @ 150W.
- Line regulation: ±0.5% maximum at full load.
- Inrush current: 45 A @ 115 VAC, at 25°C cold start; 90 A @ 230 VAC, at 25°C cold start.
- Operating altitude: 5000 meters above sea level.
- Withstand voltage: 3000 VAC from input to output, 1500 VAC from input to ground, 1500 VAC from output to ground.
- Isolation Resistance: Input to output 100M ohm @ 500Vdc, 25°C.
- MTBF: 400,000 hours mini. at full load at 25°C ambient, calculated per BELL CORE SR-332.
EMC Performance
- EN55032: Class B conducted, Class B radiated
- FCC: Class B conducted, Class B radiated
- VCCI: Class B conducted, Class B radiated
- EN61000-3-2: Harmonic distortion, Class A and D
- EN61000-3-3: Line flicker
- EN61000-4-2: ESD, ±8 KV air and ±4 KV contact
- EN61000-4-3: Radiated immunity, 3 V/m
- EN61000-4-4: Fast transient/burst, ±1 KV
- EN61000-4-5: Surge, ±2 KV differential, ±4 KV common mode
- EN61000-4-6: Conducted immunity, 3 Vrms
- EN61000-4-8: Magnetic field immunity, 1 A/m
- EN61000-4-11: Voltage dip immunity: 30% reduction for 500 ms, criteria A; >95% reduction for 10 ms, criteria A; >95% reduction for 5000 mS, criteria B.
Performance Graphs
Input Voltage Derating Curve
This graph illustrates the relationship between input voltage and output power. The X-axis represents Input Voltage (Vac) ranging from 90 to 264V. The Y-axis represents % Output Power. The curve shows that output power is maintained at 100% across the specified input voltage range (90-264 VAC), indicating no derating due to input voltage variations within this range.
Output Power Derating Curve
This graph shows how the maximum load capacity of the power supply is affected by ambient temperature. The X-axis represents Temperature (°C) from -20°C to 70°C. The Y-axis represents % Max Load. The curve indicates that the power supply can deliver 100% of its maximum load up to approximately 50°C. Beyond 50°C, the maximum load capacity is derated linearly, reaching 50% at 70°C. This derating applies to both convection and forced-air cooling conditions.
Output Voltage/Current Rating Chart
Model | Voltage | Min. Load | Max. Current (convection) | Max. Current (7 CFM) | Tolerance | Ripple & Noise | Max. Power | Efficiency (115/230 Vac, typical) |
---|---|---|---|---|---|---|---|---|
FSP150-P35-A12 | 12 V | 0 A | 8.34 A | 12.5 A | ±3% | 120 mV | 100 W / 150 W | 90 / 92% |
FSP150-P35-A24 | 24 V | 0 A | 4.17 A | 6.25 A | ±3% | 200 mV | 100 W / 150 W | 89 / 91% |
FSP150-P35-A54 | 54 V | 0 A | 1.86 A | 2.78 A | ±3% | 300 mV | 100 W / 150 W | 91 / 92% |
Notes:
- Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 47 µF electrical capacitor in parallel with a 0.1 µF ceramic capacitor across the output.
- The first value of maximum current is at convection cooling. The second value is with 7 CFM forced air provided by user.
Mechanical Specifications
Dimensions are shown in millimeters (mm).
Overall Dimensions: Approximately 115.80 mm (length) x 94.0 mm (width) x 28.0 mm (height).
Connectors and Pin Assignments:
IN1 (AC Input):
- Pin 1: Neutral (N)
- Pin 2: Ground (JW)
- Pin 3: Line (L)
CN200 (DC Output):
- Pins 1, 2, 3: +12V (JW)
- Pins 4, 5, 6: GND (A3963WV2-6P or equivalent)
CN201 (DC Output):
- Pin 1: +12V (JW)
- Pin 2: GND (A3963WV2-2P or equivalent)