Resistex Miks LED Luminaire
Installation Instructions
Safety Notes
- Never work on the luminaire when it is live (under voltage). ⚡
- Installation must be performed by a professional installer, adhering to all relevant electrical installation standards and regulations.
- Risk of electrostatic discharges (ESD Norm). Handle with necessary precautions.
- Please observe the provided notes and follow the mounting steps carefully.
Maintenance Instructions
- Do not use chemical or abrasive products to clean the luminaire.
- Keep these instructions for future dismantling or maintenance work.
- Additional information about RESISTEX luminaires is available on the website: www.resistex-sa.com
- RESISTEX cannot be held responsible for any misuse of the product.
Installation Steps
Options / Accessories
Adjustable / Orientable
- Step 1: Illustrates a circular fixture with a rotating ring, indicating adjustability.
- Step 2: Shows the fixture being inserted upwards into a mounting bracket.
- Step 3: Depicts the ring being rotated to adjust the fixture's angle.
Low Luminance / Basse Luminance
- Step 1: Shows a fixture with a diffuser or lens.
- Step 2: Depicts clips or springs attached to the fixture.
- Step 3: Shows the fixture being inserted into a mounting bracket, with the springs engaging to secure it.
Montage / Installation
- Step 1: Provides dimensions for the ceiling cutout: Ø69 mm (+/-1 mm). It also shows the fixture itself.
- Step 2: The fixture is shown being pushed upwards into the prepared ceiling opening. ⬆️
- Step 3: The fixture is rotated to secure it in place. ↪️
- Step 4: Illustrates the electrical connection: wires are prepared and inserted into a connection block.
- Step 5: The connection block is shown being closed after the wires are inserted.
- Step 6: Shows the connection block being opened again, with wires correctly inserted into terminals.
- Step 7: A terminal block is depicted with connections for Live (L), Neutral (N). Wires are shown connected to these terminals.
- Step 8: The fixture is shown with its spring clips extended, ready for insertion into the ceiling.
- Step 9: A diagram shows correct electrical connection (checkmark ✔️) with a stable waveform, and incorrect connection (cross ❌) with a distorted or absent waveform.
- Step 10: The final installation shows the Miks luminaire flush with the ceiling surface.
RESISTEX EXPLOITATION
11 Quai de la Banquière CS 80010, 06730 Saint-André-de-la-Roche - France
Tél. 04 93 276 276 - Fax 04 93 276 280 - contact@resistex-sa.com
APE 2740Z - Siret 487 593 477 00010 - SAS CAPITAL 649979 € - T.V.A. F.R. 73 487 593 477
Website: www.resistex-sa.com
Certifications: ROHS Class II IP65 IK07 CE 5 Years Warranty