INKBIRD IHC-200 Plug-n-Play Humidity Controller User Manual
Version 1.3s
Overview
What is IHC-200?
The IHC-200 is an easy-to-use, safe, and reliable dual relay output humidity controller. Its plug-and-play design and dual LED screens offer a more user-friendly experience. The IHC-200 can control any 100-265 volt humidifier, dehumidifier, or fan.
Main Features
- Automatically switches between humidification and dehumidification modes.
- Controls humidity by setting value and differential value.
- Calibrates the humidity value.
- Provides delay protection for control output.
- Allows querying current temperature.
- Alarms when humidity exceeds high/low humidity setting values.
- Alarms when there is a sensor error or humidity exceeds limits.
Specification
Parameter | Value |
---|---|
Power Input | 100 ~240VAC, 50Hz/60Hz |
Power Output | Max. 10A, 100V ~240V AC |
Power Consumption | <3W |
Humidity Measuring Range | 5%-99.99%RH |
Humidity Control Range | 5%-99%RH |
Resolution | 1%RH |
Accuracy | ±3%RH |
Sensor Model | HTG3535CH |
Sensor Stability | <0.5%RH/yr |
Sensor Length | 2m / 6.56ft |
Relay Contact Capacity | Humidification (12A, 100-240VAC) Dehumidification (12A, 100-240VAC) |
Input Power Cable Length | 1.5m (5ft) |
Output Power Cable Length | 30cm (1ft) |
Dimension | Main Body: 140x68x33mm (5.5x2.7x1.3 inch) Socket (US Version): 85x42x24mm (3.3x1.7x1.0 inch) Socket (EU Version): 135x54x40mm (5.3x2.1x1.6 inch) Socket (UK Version): 140x51x27mm (5.5x2.0x1.0 inch) |
Ambient Temperature | -30~75°C / -22~167°F |
Storage | Temperature -30~75°C / -22~167°F Humidity 20~85% (No Condensate) |
Warranty | 1 Year |
Keys Instruction
The controller features several keys and indicator lamps for operation and status indication.
- ① PV: Process Value
- Under running mode, displays current humidity.
- Under setting mode, displays menu code.
- When pressing the decrease and increase keys simultaneously, it displays the current temperature.
- ② SV: Setting Value
- Under running mode, displays setting humidity.
- Under setting mode, displays setting value.
- ③ Humidification Indicator Lamp ?
- On: Humidification Working.
- Off: Humidification Stop Working.
- ④ Dehumidification Indicator Lamp ?
- On: Dehumidification Working.
- Off: Dehumidification Stop Working.
- Flicker: Dehumidification Delay.
- ⑤ SET key ⚙️
- Press SET key for 3 seconds to enter the menu for function setting. During the setting process, press SET key for 3 seconds to quit and save setting changes.
- ⑥ INCREASE key ▲
- Under running mode, press INCREASE key to inquire HD value.
- Under setting mode, press INCREASE key to increase value.
- ⑦ DECREASE key ▼
- Under running mode, press DECREASE key to inquire DD value.
- Under setting mode, press DECREASE key to decrease value.
Device Sockets
The controller has sockets for connecting humidification and dehumidification devices.
- Humidification Device Socket ?
- Humidification output.
- Dehumidification Device Socket ?
- Dehumidification output.
Key Operation Instruction
4.1 Power On/Off
To power off: When the controller is working normally, press and hold the '▲' and '▼' keys simultaneously for 3 seconds. All displays and outputs will turn off.
To power on: When the controller is powered off, press and hold the '▲' and '▼' keys simultaneously for 1 second to enter normal measuring mode.
4.2 Enquiry Differential Value
When the controller is working normally, short press the '▲' key once to display the humidification differential (HD). Short press the '▼' key once to display the dehumidification differential (DD). After two seconds, the display returns to the normal humidity mode.
4.3 Enquiry Measuring Temperature
Press the '▲' and '▼' keys simultaneously. The current temperature value will be displayed on the PV screen. Release the keys after 2 seconds to return to the normal display mode.
4.4 How to Set Parameters
When the controller is working normally, press and hold the 'SET' key for 3 seconds to enter parameter setting mode. The PV screen displays the first menu code “HS”, while the SV screen displays the current setting value. Press the '▲' key to page down through the menu codes. Press the '▼' key to change the current parameter values.
After finishing settings, press and hold the 'SET' key for 3 seconds in any status to save the parameter settings and return to the normal humidity display mode. If there is no operation for 10 seconds during setting, the system will automatically quit the menu and return to the normal display mode without saving the parameter modifications.
4.5 Setup Flow Chart
To enter setup mode, press and hold the 'SET' key for over 3 seconds. The controller then enters a sequence of parameter settings: Humidity Set Value (HS), Humidification Differential Value (HD), Dehumidification Differential Value (DD), Alarm High Humidity Set Value (AH), Alarm Low Humidity Set Value (AL), Delay Protection Value (PT), and Humidity Calibration (CA). Each setting is accessed by pressing 'SET'. After setting 'CA', press and hold 'SET' for 3 seconds to save and return to normal working mode.
Menu Instruction
Menu Code | Function | Setting Range | Default | Unit | Remarks |
---|---|---|---|---|---|
HS | Humidity Set Value | 5~99 | 50 | % RH | 5.1 |
HD | Humidification Differential Value | 1~20 | 5 | % RH | 5.1 |
DD | Dehumidification Differential Value | 1~20 | 5 | % RH | 5.1 |
AH | Alarm High Humidity Set Value | 50~99 | 99 | % RH | 5.2 |
AL | Alarm Low Humidity Set Value | 0~50 | 0 | % RH | 5.2 |
PT | Delay Protection Value | 0~10 | 1 | minute | 5.3 |
CA | Humidity Calibration | -10~10 | 0 | % | 5.4 |
5.1 Temperature Control Range Setting (HS, HD, DD)
When the controller is working normally, the LED displays the current measured humidity. It then automatically starts recognizing and translating humidifying and dehumidifying actions.
When the measured humidity PV ≥ HS (Humidity Set Value) + DD (Dehumidification Differential Value), the controller enters dehumidification status. The dehumidification indicator lamp turns on, and the dehumidification relay works. When the dehumidification indicator light is flickering, the dehumidifying equipment is in delay protection status. When the measured humidity PV ≤ HS (Humidity Set Value), the dehumidification indicator lamp turns off, and the dehumidification relay stops working.
When the measured humidity PV ≤ HS (Humidity Set Value) - HD (Humidification Differential Value), the controller enters humidification status. The humidification indicator lamp turns on, and the humidification relay works. When the measured humidity PV ≥ HS (Humidity Set Value), the humidification indicator lamp turns off, and the humidification relay stops working.
5.2 Alarm High/Low Limit Setting (AH, AL)
When the measured humidity PV ≥ AH (Alarm High Humidity Set Value) or the measured humidity PV ≤ AL (Alarm Low Humidity Set Value), an alarm sounds ("BI-BI-BIII"). The current value, AH, or AL will display on the PV screen. The alarm sound can be stopped by pressing any key, but the alarm status will not change until the measured humidity returns to the normal range.
5.3 Compressor Delay (PT)
Under dehumidification mode, after power on, if the measured humidity PV ≥ HS (Humidity Set Value) + DD (Dehumidification Differential Value), the equipment will not start dehumidification immediately but will wait for a preset delay time.
If the time interval between two dehumidification operations (or the time from power on to dehumidify) is larger than the preset delay, the equipment will start dehumidification immediately. If the time interval is less than the preset delay, the equipment will not start dehumidification until the preset delay is satisfied.
The delay time is calculated right after the moment dehumidification stops.
5.4 Humidity Calibration (CA)
When there is a deviation between the measured humidity and the actual humidity, use the humidity calibration function to align them. The corrected humidity is equal to the humidity before calibration plus the corrected value (the corrected value can be positive, zero, or negative).
Error Description
Sensor fault alarm ⚠️
When the humidity sensor is in a short circuit or open loop, the controller will initiate a sensor fault mode and cancel all actions. The buzzer will alarm, and the LED will display "ER". The buzzer alarm can be dismissed by pressing any key. After the faults are solved, the system will return to normal working mode.
Technical Assistance and Warranty
7.1 Technical Assistance
If you encounter any problems installing or using this controller, please carefully and thoroughly review this instruction manual. For assistance, please write to cs@ink-bird.com. Replies will be sent within 24 hours from Monday through Saturday.
You can also visit our website www.ink-bird.com to find answers to common technical questions.
7.2 Warranty
INKBIRD TECH. C.L. warrants this controller for one year from the date of purchase, when operated under normal conditions by the original purchaser (non-transferable), against defects caused by INKBIRD's workmanship or materials. This warranty is limited to the repair or replacement, at INKBIRD's discretion, of all or part of the controller. The original receipt is required for warranty purposes.
INKBIRD is not responsible for injury, property damage, or other consequential damages or damages of third parties arising directly from the actual or alleged defects in workmanship of the product.
There are no representations, warranties, or conditions, express or implied, statutory or otherwise, other than those contained herein, as per the sale of goods act or any other statute.
Contact Us
Business Contact: sales@ink-bird.com
Technical Support: cs@ink-bird.com
Business Hours: 09:00-18:00 (GMT+8) from Monday to Friday
URL: www.ink-bird.com