IHC-200 Plug and Play Humidity Controller
1. Overview
Purpose of IHC-200
The IHC-200 is an easy-to-use, safe, and reliable humidity controller with dual relay outputs. The dual LED display and plug-and-play setup allow for more intuitive user control. The IHC-200 can control any humidifier, dehumidifier, or fan with a voltage of 100-240V.
Main Functions
- Automatic switching between humidification and dehumidification modes.
- Humidity control using a set differential value.
- Humidity calibration.
- Setting a delay for compressor activation for dehumidification.
- Requesting current temperature.
- Audible alarm when humidity exceeds high/low limits.
- Alarm in case of error.
2. Technical Specifications
Parameter | Value |
---|---|
Power Supply | 100 ~ 240VAC, 50Hz / 60Hz |
Max Current of Connected Devices | Max. 10A, 100V~240V AC |
Power Consumption | <3W |
Humidity Measurement Range | 5% -99.99% RH |
Humidity Control Range | 5%-99% RH |
Minimum Setting Step | 1% RH |
Accuracy | ±3% RH |
Sensor Model | HTG3535CH |
Sensor Stability | <0.5%RH/yr |
Sensor Cable Length | 2 m / 6.56 ft |
Humidifier Relay Rating | 12A, 100-240 VAC |
Dehumidifier Relay Rating | 12A, 100-240 VAC |
Device Power Cable Length | 1.5 m (5 ft) |
Device Connection Cable Length | 30 cm (1 ft) |
Dimensions (Main Unit) | 140x68x33 mm (5.5x2.7x1.3 inches) |
Dimensions (Socket - US version) | 85x42x24 mm (3.3x1.7x1.0 inches) |
Dimensions (Socket - EU version) | 135x54x40 mm (5.3x2.1x1.6 inches) |
Dimensions (Socket - UK version) | 140x51x27 mm (5.5x2.0x1.0 inches) |
Ambient Operating Temperature | -30 ~ 75 °C / -22 ~ 167 °F |
Storage Conditions | Temperature -30 ~ 75 °C / -22 ~ 167 °F, Humidity 20 ~ 85% (non-condensing) |
Warranty | 1 year |
3. Appearance and Controls
The device features a dual LED display and several control buttons. It also includes indicator lights for humidification and dehumidification.
Device Components
- 1. Upper LED Display (PV): Displays the current process. In operation mode, it shows the current humidity. In setting mode, it displays the menu code. Pressing the '▲' and '▼' buttons simultaneously shows the current temperature.
- 2. Lower LED Display (SV): Displays the set process. In operation mode, it shows the user-set humidity. In setting mode, it displays the setting value.
- 3. Humidification Indicator Light: Indicates when humidification is active (on) or inactive (off).
- 4. Dehumidification Indicator Light: Indicates when the dehumidifier is active (on) or inactive (off). It flashes when the dehumidification delay is active.
- 5. SET Button: Press and hold for 3 seconds to enter the function setting menu. Press and hold for 3 seconds to exit and save settings.
- 6. UP Button (▲): In operation mode, press to request the HD value. In setting mode, press to increase the value.
- 7. DOWN Button (▼): In operation mode, press to request the DD value. In setting mode, press to decrease the value.
- 8. Humidification Device Socket: Connects to the humidification device.
- 9. Dehumidification Device Socket: Connects to the dehumidification device.
Socket Types
The device is compatible with various socket types, including US, EU, UK, and AU standards, allowing for flexible connection of humidification and dehumidification equipment.
4. Operations
4.1 Power On/Off
To turn off the controller in normal operation mode, simultaneously press and hold the 'SET', '▲', and '▼' buttons for 3 seconds. To turn on the controller and enter normal measurement mode, simultaneously press and hold 'SET', '▲', and '▼' for 1 second.
4.2 Requesting Stored Data
In normal operation mode, briefly press the '▲' button to display the set humidity differential for humidification (HD). Briefly press the '▼' button to display the set humidity differential for dehumidification (DD). The screen will return to normal data display after 2 seconds.
4.3 Requesting Temperature Measurement
In normal operation mode, simultaneously press and hold '▲' and '▼' for 1 second. The current temperature will be displayed on the PV screen. The screen will return to normal data display after 2 seconds.
4.4 Parameter Settings
To enter parameter setting mode from normal operation, press and hold the 'SET' button for over 3 seconds. The 'SET' indicator will turn on. The PV screen will show the menu code (e.g., 'HS'), and the SV screen will show the setting value. Use the '▲' or '▼' buttons to adjust the value. Press 'SET' to move to the next menu item. After completing all settings, press and hold 'SET' for 3 seconds to save changes and return to normal mode. If no operation is performed for 10 seconds, the system will exit setting mode without saving.
4.5 Setting Flowchart
The setting process is navigated using the 'SET', '▲', and '▼' buttons. After initiating the setting mode by holding 'SET' for over 3 seconds, you can cycle through and adjust parameters:
- Press 'SET' to confirm and proceed.
- HS (Set Humidity Value): Default 50%RH.
- HD (Humidity Differential for Humidification): Default 5%RH.
- DD (Humidity Differential for Dehumidification): Default 5%RH.
- AH (Upper Audible Alarm Limit): Default 99%RH.
- AL (Lower Audible Alarm Limit): Default 0%RH.
- PT (Compressor Delay): Default 1 minute.
- CA (Humidity Calibration): Default 0%RH.
After adjusting the 'CA' parameter and pressing 'SET', the system returns to the 'Working State' or normal operation mode.
5. Menu Instruction
Menu Code | Function | Range | Default | Unit | Note |
---|---|---|---|---|---|
HS | Set Humidity Value | 5~99 | 50 | %RH | 5.1 |
HD | Humidity Differential for Humidification | 1~20 | 5 | %RH | 5.1 |
DD | Humidity Differential for Dehumidification | 1~20 | 5 | %RH | 5.1 |
AH | Upper Audible Alarm Limit | 50~99 | 99 | %RH | 5.2 |
AL | Lower Audible Alarm Limit | 0~50 | 0 | %RH | 5.2 |
PT | Compressor Delay | 0~10 | 1 | minute | 5.3 |
CA | Humidity Calibration | -10~10 | 0 | % | 5.4 |
6. Parameter Settings Details
5.1 Humidity Control Range Setting (HS, HD, DD)
When the controller operates normally, the LED display shows the current measured humidity and automatically determines and switches between humidification and dehumidification modes.
When measured humidity PV ≥ HS (set humidity value) + DD (dehumidification differential value), the system enters dehumidification mode, the dehumidification indicator light turns on, and the dehumidification relay starts working. If the dehumidification indicator flashes, it means the dehumidification equipment is in a set pause mode to protect the compressor. When measured humidity PV ≤ HS (set humidity value), the dehumidification indicator turns off, and the dehumidification relay stops working.
When measured humidity PV ≤ HS (set humidity value) - HD (humidification differential value), the system enters humidification mode, the humidification indicator light turns on, and the humidification relay starts working. When measured humidity PV ≥ HS (set humidity value), the humidification indicator turns off, and the humidification relay stops working.
5.2 Upper / Lower Audible Alarm Limit Setting (AH, AL)
When measured humidity PV ≥ AH or PV ≤ AL, the high/low humidity audible alarm will trigger. The device will emit a 'bi-bi-Biii' tone until the humidity becomes lower than AH / higher than AL, or until any key is pressed.
5.3 Compressor Delay Setting (PT)
In dehumidification mode, after power on, if the measured humidity PV ≥ HS (set humidity value) + DD (dehumidification differential value), the equipment will not start dehumidifying immediately until the set delay time has passed. If the time interval between two dehumidification operations exceeds the set delay, the equipment will start dehumidifying immediately. If the time interval between two dehumidification periods is less than the set delay, the equipment will not start dehumidifying until the set delay is completed. The delay timer starts counting immediately after dehumidification stops.
5.4 Humidity Calibration (CA)
If there is a difference between the measured humidity and the actual humidity, use the humidity calibration function to align the measured humidity value with the actual humidity. The corrected humidity is equal to the humidity before calibration plus the corrected value (the corrected value can be a positive value, 0, or a negative value).
7. Possible Malfunctions
Sensor Malfunction Alarm
When the humidity sensor is short-circuited or open-circuited, the controller will activate the sensor malfunction mode and cancel all actions. The device will emit an audible signal, and the LED will display 'ER'. The audible alarm can be turned off by pressing any key. After the malfunction is resolved, the system will return to normal operating mode.
8. Technical Support and Warranty
7.1 Technical Assistance
If you encounter any problems with the installation or use of this humidity controller, please read the instruction manual carefully and thoroughly. For assistance, please email us at cs@ink-bird.com. We will reply to your email within 24 hours from Monday to Saturday. You can also visit our website www.ink-bird.com for answers to common technical questions.
7.2 Warranty
INKBIRD TECH. C.L. provides a one-year warranty for the humidity controller from the date of purchase, provided the original purchaser (non-transferable) operated it under normal conditions. The warranty covers defects caused by INKBIRD's manufacturing quality or materials. This warranty is limited to repair or replacement, at INKBIRD's discretion, of all or part of the controller. The original receipt is required for warranty purposes. INKBIRD is not responsible for property damage or other indirect losses, including third-party losses, resulting directly from the actual or alleged manufacturing quality of the product. There are no representations, warranties, or conditions, express or implied, statutory or otherwise, contained herein or in any bill of sale or other statute.