INKBIRD IHC-200 Humidity Controller
SMART HOME | SMART LIFE
Safety Precautions
Please read the specifications carefully before using the product.
- Do not touch the terminals during power-on. This may cause injury due to electric shock.
- Do not allow metal scraps, wire cuttings, fine metal shavings from installation to enter the product. This may cause electric shock, fire, or malfunction.
- Do not use the product in areas exposed to flammable or explosive gases. Otherwise, an explosion may occur.
- Never disassemble, modify, or repair the product, or touch any internal parts. Electric shock, fire, or malfunction may occur.
- If the output relays are used beyond their lifespan, fusion or burning may occur. Always consider the application conditions and use the output relays within their load and electrical life limits.
- Do not immerse the product in water or seawater.
01 Overview
What is IHC-200?
The IHC-200 is an easy-to-use, safe, and reliable humidity controller equipped with a dual output relay. Its plug-n-play design and dual LED display make it more user-friendly. The IHC-200 can control any humidifier, dehumidifier, fan, etc., powered by a voltage from 100 to 265 volts.
Main Features
- Automatic Selection in Humidification or Dehumidification Process
- Humidity Control by Setting the Value and Differential Value
- Humidity Calibration
- Delay Protection for Control Output
- Current Temperature Reading
- Alarm when humidity exceeds the upper or lower set limit
- Alarm in case of sensor error or exceeding humidity limit
02 Specifications
Parameter | Value |
---|---|
Power Supply Voltage | 100~240V, 50Hz / 60Hz |
Output Power | 10A, 100~240V AC Max. |
Power Consumption | < 3 watts |
Humidity Measuring Range | 5~99.99% RH |
Humidity Control Range | 5~99% RH |
Resolution | 1% RH |
Accuracy | ± 3% RH |
Sensor Model | HTG3535CH |
Sensor Stability | < 0.5% RH/yr |
Probe Length | 2 m / 6.56 feet |
Relay Contact Capacity | Humidification (12A, 100 ~ 240 VAC), Dehumidification (12A, 100 ~ 240 VAC) |
Power Cable Length | 1.5 m (5 feet) |
Output Cable Length | 30 cm (1 foot) |
Dimension | Main Body: 140x68x33 mm (5.5x2.7x1.3 inch) Output Plug: US Version: 85x42x24 mm (3.3x1.7x1.0 inch) EU Version: 135x54x40 mm (5.3x2.1x1.6 inch) UK Version: 140x51x27 mm (5.5x2.0x1.0 inch) |
Ambient Temperature | -30~75°C / -22 ~ 167°F |
Storage | Temperature: -30 ~ 75°C / -22 ~ 167°F Humidity: 20 ~ 85% (Non-Condensing) |
Warranty | 1 year |
03 Button Instructions
The controller features a dual display and several buttons for operation and setting adjustments.
Display:
- PV (Present Value): Displays the currently measured humidity. In setting mode, it shows the menu code. Pressing buttons 6 and 7 simultaneously displays the current temperature (°C).
- SV (Setting Value): Displays the programmed humidity. In setting mode, it shows the selected value.
LED Indicators:
- WORK1 (Dehumidification Indicator): Solid light indicates dehumidification is in progress. Flashing light indicates a delay before dehumidification starts.
- WORK2 (Humidification Indicator): Solid light indicates humidification is in progress.
Buttons:
- SET: Press and hold for 3 seconds to enter the setting menu. Press and hold for 3 seconds at any time during setting to save parameters and exit to normal operation.
- UP (▲): In normal operation, press to check the programmed HD value. In setting mode, press to increase the value.
- DOWN (▼): In normal operation, press to check the programmed CD value. In setting mode, press to decrease the value.
Output Sockets:
- 8: Humidification Device Socket
- 9: Dehumidification Device Socket
04 Operation Instructions
4.1 Power On / Off
- To turn on the controller, press and hold the "SET" button for 1 second.
- To turn off the controller, press and hold the "SET", "▲", and "▼" buttons simultaneously for 3 seconds. The displays will turn off, and the outputs will be cut.
4.2 Checking Differential Values
- In normal operation, press "▲" to display the humidification differential value (HD).
- Press "▼" to display the dehumidification differential value (DD).
- After 2 seconds, the humidity display will reappear.
4.3 How to Set Parameters
In normal operation, press and hold "SET" for 3 seconds to enter the setting mode. The PV screen will display the first menu code "HS", and the SV screen will show the corresponding value.
Press "SET" to cycle through the menu. When the desired parameter code is displayed, use "▲" or "▼" to adjust the setting value.
When settings are complete, press and hold "SET" for 3 seconds to save the parameters and return to normal humidity display mode.
If no operation is performed for 10 seconds during setting, the system will automatically exit the menu without saving and return to normal humidity display mode.
4.4 Setting Diagram
Press "SET" for 3s to Enter Setting Mode
- HS (Humidity Setting Value): Adjust humidity setpoint.
- HD (Humidity Differential): Set the humidity differential for humidification.
- DD (Dehumidification Differential): Set the humidity differential for dehumidification.
- AH (High Humidity Alarm): Set the high humidity alarm limit.
- AL (Low Humidity Alarm): Set the low humidity alarm limit.
- PT (Delay Protection): Set the delay time for compressor protection.
- CA (Humidity Calibration): Calibrate the humidity reading.
Normal Operation
05 Setting Menu
Code | Function | Range | Default | Unit | Remarks |
---|---|---|---|---|---|
HS | Humidity Setting Value | 5~99 | 50 | % RH | 5.1 |
HD | Humidity Differential for Humidification | 1~20 | 5 | % RH | 5.1 |
DD | Humidity Differential for Dehumidification | 1~20 | 5 | % RH | 5.1 |
AH | High Humidity Alarm Value | 50~99 | 99 | % RH | 5.2 |
AL | Low Humidity Alarm Value | 0~50 | 0 | % RH | 5.2 |
PT | Delay Protection Value | 0~10 | 1 | minute | 5.3 |
CA | Humidity Calibration | -10~10 | 0 | % | 5.4 |
5.1 Setting the Humidity Control Range (HS, HD, DD)
In normal operation, the PV screen displays the measured humidity and automatically manages humidification and dehumidification.
Dehumidification: When the measured humidity PV is ≥ HS (Humidity Setting Value) + DD (Dehumidification Differential Value), the unit will enter dehumidification mode. The dehumidification indicator (WORK1) will light up, and the dehumidification relay will activate. If the dehumidification indicator flashes, it means the dehumidification device is in a protection delay period. When the measured humidity PV is ≤ HS (Humidity Setting Value), the dehumidification indicator will turn off, and the dehumidification relay will stop working.
Humidification: When the measured humidity PV is ≤ HS (Humidity Setting Value) - HD (Humidification Differential Value), the unit will enter humidification mode. The humidification indicator (WORK2) will light up, and the humidification relay will activate. When the measured humidity PV is ≥ HS (Humidity Setting Value), the humidification indicator will turn off, and the humidification relay will stop working.
5.2 Setting High and Low Limit Alarms (AH, AL)
When the measured humidity PV is ≥ AH (High Humidity Alarm Value) or PV ≤ AL (Low Humidity Alarm Value), the alarm will sound "bi-bi-biii", and the current AH or AL value will be displayed on the PV screen. The sound can be stopped by pressing any button, but the alarm mode will remain active until the measured humidity returns to the normal range.
5.3 Compressor Delay (PT)
In dehumidification mode, after power-on, if the measured humidity PV is ≥ HS (Humidity Setting Value) + DD (Dehumidification Differential Value), the device will not start dehumidification immediately but will wait for a delay period.
If the time interval between two dehumidification operations (or the delay from power-on to dehumidification) is longer than the preset delay, dehumidification will start immediately. If the time interval between two dehumidification operations (or the delay from power-on to dehumidification) is shorter than the preset delay, dehumidification will not start until the preset delay is met.
The delay will be calculated from the moment dehumidification stops.
5.4 Humidity Calibration (CA)
If there is a discrepancy between the measured humidity and the actual humidity, use the calibration function to align the measured humidity with the actual humidity. The corrected humidity is equal to the humidity before calibration + the corrected value (the corrected value can be a positive value, 0, or a negative value).
06 Error Description
Sensor Failure Alarm
When the humidity sensor is short-circuited or open-circuited, the controller will trigger the sensor failure mode and cancel all actions. The buzzer will sound, and the screen will display "ER". Press any button to disable the alarm. Once the problem is corrected, the system will return to normal operation mode.
07 Technical Support and Warranty
7.1 Technical Support
For assistance, please email support@ink-bird.com. Responses will be provided within 24 hours from Monday to Saturday.
Visit the website www.ink-bird.com for answers to frequently asked technical questions.
7.2 Warranty
INKBIRD TECH. C.L. warrants this thermostat for one year from the date of purchase when used under normal conditions by the original purchaser (non-transferable), against defects caused by manufacturing or materials of INKBIRD. This warranty is limited to the repair or replacement, at INKBIRD's discretion, of all or part of the thermostat. The original receipt is required for warranty purposes.
INKBIRD is not responsible for property damage caused by injury or other consequential damages, or damages caused by third parties directly from actual or presumed manufacturing of the product.
There are no representations, warranties, or conditions, express or implied, statutory or otherwise, other than those contained in the law on the sale of goods or any other statute.