Specifications
Location | Exterior |
Class | Class I |
IP rating | IP56 |
Driver required | No |
Fire rating | No |
Cable length | 3000mm |
Bulb type | GU10 |
Max wattage | 8W |
Bulb included | No |
Switched | No |
Dimmable | Bulb dependent |
Rated voltage | 220V-240V |
Rated frequency | 50-60Hz |
Safety Precautions
Lights must be installed by a qualified electrician. All lights should be installed in dry conditions. Turn off electrical supply to circuit before installation.
Installation Steps
- Align the spotlight direction with the spike.
- Remove the light body and hammer the spike into position.
- Cover the base with the brass spike cover.
- Feed the cable into position.
- Place the light and tighten the collar.
- Add a GU10 bulb.
- Fit the glass bulb cover using the tool provided.
Path Spotlight
Included Components
- Light body x1
- Spike x1
- Rubber gasket x1
- Spike cover x1
- Glass bulb cover x1
- Glass bulb cover tool x1
Tools You'll Need
- Hammer/mallet ?
Specifications
Location | Exterior |
Class | Class I |
IP rating | IP56 |
Driver required | No |
Fire rating | No |
Cable length | 3000mm |
Bulb type | GU10 |
Max wattage | 8W |
Bulb included | No |
Switched | No |
Dimmable | Bulb dependent |
Rated voltage | 220V-240V |
Rated frequency | 50-60Hz |
Safety Precautions
Lights must be installed by a qualified electrician. All lights should be installed in dry conditions. Turn off electrical supply to circuit before installation.
Installation Steps
- Align the spotlight direction with the spike.
- Remove the light body and hammer the spike into position.
- Cover the base with the brass spike cover.
- Feed the cable into position.
- Place the light and tighten the collar.
- Add a GU10 bulb.
- Fit the glass bulb cover using the tool provided.
Surface Spotlight
Included Components
- Light body x1
- Wall mount x1
- Wall mount cover x1
- Nylon washer x3
- Anchor screw x3
- Anchor x3
- Glass bulb cover x1
- Glass bulb cover tool x1
Tools You'll Need
- Drill ड्रिल
- 6mm drill bit
- Crosshead screwdriver ?
Specifications
Location | Exterior |
Class | Class I |
IP rating | IP56 |
Driver required | No |
Fire rating | No |
Cable length | 3000mm |
Bulb type | GU10 |
Max wattage | 8W |
Bulb included | No |
Switched | No |
Dimmable | Bulb dependent |
Rated voltage | 220V-240V |
Rated frequency | 50-60Hz |
Safety Precautions
Lights must be installed by a qualified electrician. All lights should be installed in dry conditions. Turn off electrical supply to circuit before installation.
Installation Steps
- Drill holes, set anchors and screw the mount to the wall.
- Feed the cable through the mount and down (or through) the wall. Install the wall mount cover.
- Fit the light body and tighten the wall mount cover to secure.
- Add a GU10 bulb.
- Fit the glass cover using the tool provided.
Flush Spotlight
Included Components
- Light body x1
- Rubber gasket x1
- 2-terminal WAGO x1
- 3-terminal WAGO x3
- Wall mount x1
- Wall screw x3
- Anchor x3
- Glass bulb cover x1
- Glass bulb cover tool x1
Tools You'll Need
- Drill ड्रिल
- 6mm drill bit
- Crosshead screwdriver ?
Specifications
Location | Exterior |
Class | Class I |
IP rating | IP56 |
Driver required | No |
Fire rating | No |
Cable length | 3000mm |
Bulb type | GU10 |
Max wattage | 8W |
Bulb included | No |
Switched | No |
Dimmable | Bulb dependent |
Rated voltage | 220V-240V |
Rated frequency | 50-60Hz |
Safety Precautions
Lights must be installed by a qualified electrician. All lights should be installed in dry conditions. Turn off electrical supply to circuit before installation.
Installation Steps
- Drill holes, set anchors and screw the mount to the wall.
- Feed the cable through the mount and down (or through) the wall. Install the wall mount cover.
- Make connections using the WAGOs.
- Fit the light body and tighten the wall mount cover to secure.
- Add a GU10 bulb.
- Fit the glass cover using the tool provided.
Straight Connector
Included Components
- Connector x1
- Grommet x1
Specifications
Location | Exterior |
IP rating | IP68 |
Fire rating | No |
Safety Precautions
These products must be installed by a qualified electrician. Turn off electrical supply to circuit before installation.
Installation Steps
- Note: swap grommets when using armoured cable. Connect the wires using the waterproof terminal.
- Screw the clamps on.
- Hide the connector and cable as required, such as underground.
Split T Connector
Included Components
- Connector x1
- Grommet x1
Specifications
Location | Exterior |
IP rating | IP68 |
Fire rating | No |
Safety Precautions
These products must be installed by a qualified electrician. Turn off electrical supply to circuit before installation.
Installation Steps
- Note: swap grommets when using armoured cable. Connect the wires using the waterproof terminal.
- Screw the clamps on.
- Hide the connector and cable as required, such as underground.