Cambridge Outdoor Lighting Range Instructions
Ground Spotlight (inc. 24V)
Included Components
- Brass collar x1
- Glass lens with gasket x1
- Lamp body x1
- Ground spike x1
- Cable x1
Specifications
Feature | 24V Version | Standard Version |
---|---|---|
Location | Exterior | Exterior |
Class | Class III | Class II |
IP rating | IP56 | IP56 |
Driver required | Yes | No |
Fire rating | N/A | N/A |
Cable length | 2400mm | 2400mm |
Bulb type | MR16 | GU10 |
Max wattage | 8W | 8W |
Bulb included | No | No |
Switched | No | No |
Dimmable | Bulb dependent | Bulb dependent |
Rated voltage | 24V | 220V - 240V |
Rated frequency | 50 - 60Hz | 50 - 60Hz |
Important Installation Notes: Lights should be installed by a qualified electrician. All lights should be installed in dry conditions. Turn off electrical supply to circuit before installation.
Certifications: CE, ROHS Compliant
Installation Instructions
- Push the ground spike into the ground, ensuring it is stable. Consult a qualified electrician to connect the light to the mains power.
- Unscrew the brass collar to remove the glass lens and spring. Insert the bulb.
- Replace the glass lens, ensuring the silicone gasket is correctly positioned, and screw the collar back on.
- Important: Ensure the brass collar is tightened all the way to maintain the light's IP rating.
Ground Floodlight
Included Components
- Brass collar x1
- Glass lens with gasket x1
- Lamp body x1
- Ground spike x1
- Cable x1
Specifications
Feature | Ground Floodlight |
---|---|
Location | Exterior |
Class | Class II |
IP rating | IP56 |
Driver required | No |
Fire rating | N/A |
Cable length | 2400mm |
Bulb type | GU10 (AR111) |
Max wattage | 16W |
Bulb included | No |
Switched | No |
Dimmable | Bulb dependent |
Rated voltage | 220V - 240V |
Rated frequency | 50 - 60Hz |
Important Installation Notes: Lights should be installed by a qualified electrician. All lights should be installed in dry conditions. Turn off electrical supply to circuit before installation.
Certifications: CE, ROHS Compliant
Installation Instructions
- Push the ground spike into the ground, ensuring it is stable. Consult a qualified electrician to connect the light to the mains power.
- Unscrew the brass collar to remove the glass lens. Insert the bulb.
- Once the bulb is installed, replace the glass lens, ensuring the thicker side of the rubber gasket faces the bulb. Screw the brass collar back into place.
- Important: Ensure the brass collar is tightened all the way to maintain the light's IP rating.
Wall Spotlight (inc. 24V)
Included Components
- Mounting plate x1
- Wall plug x2
- Wall screw x2
- Lamp body x1
- Glass lens with gasket x1
- Brass collar x1
- Hex key x1
Tools You'll Need
- Drill
- 6mm drill bit
Specifications
Feature | 24V Version | Standard Version |
---|---|---|
Location | Exterior | Exterior |
Class | Class III | Class II |
IP rating | IP56 | IP56 |
Driver required | Yes | No |
Fire rating | N/A | N/A |
Cable length | 2400mm | 2400mm |
Bulb type | MR16 | GU10 |
Max wattage | 8W | 8W |
Bulb included | No | No |
Switched | No | No |
Dimmable | Bulb dependent | Bulb dependent |
Rated voltage | 24V | 220V - 240V |
Rated frequency | 50 - 60Hz | 50 - 60Hz |
Important Installation Notes: Lights should be installed by a qualified electrician. All lights should be installed in dry conditions. Turn off electrical supply to circuit before installation.
Certifications: CE, ROHS Compliant
Installation Instructions
- Drill two 6mm holes, set the anchors, and screw the mounting bracket to the wall using the provided screws. Consult a qualified electrician to connect the light to the mains power.
- Place the light body over the mounting bracket and use the grub screws to fix it in place.
- Unscrew the brass collar to remove the glass lens and spring. Insert the bulb.
- Replace the glass lens with the silicone gasket and screw the collar back on.
- Important: Ensure the brass collar is tightened all the way to maintain the light's IP rating.
Wall Floodlight
Included Components
- Mounting base x1
- Lamp body x1
- Glass lens with gasket x1
- Brass collar x1
- Wall plug x3
- Wall screw x3
- Hex key x1
Tools You'll Need
- Drill
- 6mm drill bit
Specifications
Feature | Wall Floodlight |
---|---|
Location | Exterior |
Class | Class II |
IP rating | IP56 |
Driver required | No |
Fire rating | N/A |
Cable length | 2400mm |
Bulb type | GU10 (AR111) |
Max wattage | 16W |
Bulb included | No |
Switched | No |
Dimmable | Bulb dependent |
Rated voltage | 220V - 240V |
Rated frequency | 50 - 60Hz |
Important Installation Notes: Lights should be installed by a qualified electrician. All lights should be installed in dry conditions. Turn off electrical supply to circuit before installation.
Certifications: CE, ROHS Compliant
Installation Instructions
- Remove the grommet and cut off the tip.
- Place the grommet back in its position and push the wires through it. Ensure the gasket is attached to the mounting base.
- Drill three 6mm holes and set the anchors to attach the mounting base to the wall.
- Consult a qualified electrician to make the electrical connections.
- Use the grub screws provided to attach the light to the mounting ring.
- Screw the ring onto the mounting base.
- Unscrew the brass collar and remove the glass lens. Insert the bulb.
- Once the bulb is connected, replace the glass lens with the gasket, ensuring the thicker side of the rubber gasket faces the bulb.
- Important: Ensure the brass collar is tightened all the way to maintain the light's IP rating.
IP68 Waterproof Straight Connector
Specifications:
- Location: Exterior
- IP rating: IP68
- Fire rating: No
Certifications: CE, ROHS Compliant
Included Components
- Connector x1
- Grommet x2
Installation Instructions
- Note: Swap the grommets when using armoured cable. Connect the wires using the waterproof terminal.
- Screw the clamps on.
- Hide the connector and cable, for example, underground.
IP68 Waterproof Split T Connector
Specifications:
- Location: Exterior
- IP rating: IP68
- Fire rating: No
Certifications: CE, ROHS Compliant
Included Components
- Connector x1
- Grommets x3
Installation Instructions
- Note: Swap the grommets when using armoured cable. Connect the wires using the waterproof terminal.
- Screw the clamps on.
- Hide the connector and cable, for example, underground.