Corston Cambridge Outdoor Lighting Range
Installation and Product Information
Ground Spotlight (inc. 24V)
This product must be installed in dry conditions by a qualified electrician. Turn off electrical supply to circuit before installation.
Specification | 24V | Standard |
---|---|---|
Location | Exterior | Exterior |
Class | Class III | Class II |
IP rating | IP56 | IP56 |
Driver required | Yes | No |
Fire rating | N/A | N/A |
Cable length | 2400mm | 2400mm |
Bulb type | MR16 | GU10 |
Max wattage | 8W | 8W |
Bulb included | No | No |
Switched | No | No |
Dimmable | Bulb dependent | Bulb dependent |
Rated voltage | 24V | 220V - 240V |
Rated frequency | 50-60Hz | 50-60Hz |
Included Components:
- Brass collar x1
- Lamp body x1
- Glass lens with gasket x1
- Ground spike x1
- Cable x1
Installation Instructions:
- Push the spike into the ground, ensuring it is stable. Consult a qualified electrician to connect the light to the mains power.
- Unscrew the brass collar to remove the glass lens and spring. Insert the bulb.
- Keeping the silicone gasket on the glass lens, replace the lens on top of the spring and screw the collar back on.
- Important: Ensure the brass collar is tightened all the way, as this is necessary for the IP rating of the light.
Safety Notes:
- Lights should only be installed by a qualified electrician.
- All lights must be installed in dry conditions.
- Turn off electrical supply to the circuit before installation.
Ground Floodlight
This product must be installed in dry conditions by a qualified electrician. Turn off electrical supply to circuit before installation.
Specification | Standard |
---|---|
Location | Exterior |
Class | Class II |
IP rating | IP56 |
Driver required | No |
Fire rating | N/A |
Cable length | 2400mm |
Bulb type | GU10 (AR111) |
Max wattage | 16W |
Bulb included | No |
Switched | No |
Dimmable | Bulb dependent |
Rated voltage | 220V - 240V |
Rated frequency | 50-60Hz |
Included Components:
- Brass collar x1
- Glass lens with gasket x1
- Lamp body x1
- Ground spike x1
- Cable x1
Installation Instructions:
- Push the spike into the ground, ensuring it is stable. Consult a qualified electrician to connect the light to the mains power.
- Unscrew the brass collar to remove the glass lens. Insert the bulb.
- Once the bulb is installed, replace the glass lens, ensuring the thicker side of the rubber gasket faces the bulb. Then screw the brass collar back into place.
- Important: Ensure the brass collar is tightened all the way, as this is necessary for the IP rating of the light.
Safety Notes:
- Lights should only be installed by a qualified electrician.
- All lights must be installed in dry conditions.
- Turn off electrical supply to the circuit before installation.
Wall Spotlight (inc. 24V)
This product must be installed in dry conditions by a qualified electrician. Turn off electrical supply to circuit before installation.
Specification | 24V | Standard |
---|---|---|
Location | Exterior | Exterior |
Class | Class III | Class II |
IP rating | IP56 | IP56 |
Driver required | Yes | No |
Fire rating | N/A | N/A |
Cable length | 2400mm | 2400mm |
Bulb type | MR16 | GU10 |
Max wattage | 8W | 8W |
Bulb included | No | No |
Switched | No | No |
Dimmable | Bulb dependent | Bulb dependent |
Rated voltage | 24V | 220V - 240V |
Rated frequency | 50-60Hz | 50-60Hz |
Included Components:
- Anchor x2
- Wall screw x2
- Mounting plate x1
- Lamp body x1
- Glass lens with gasket x1
- Brass collar x1
Installation Instructions:
- Drill two 6mm holes, set the anchors, and screw the mounting bracket to the wall using the screws provided. Consult a qualified electrician to connect the light to the mains power.
- Place the light body over the mounting bracket and use the grub screws provided to fix it in place.
- Unscrew the brass collar to remove the glass lens and spring. Insert the bulb.
- Keeping the silicone gasket on the glass lens, replace the lens and screw the collar back on.
- Important: Ensure the brass collar is tightened all the way, as this is necessary for the IP rating of the light.
Safety Notes:
- Lights should only be installed by a qualified electrician.
- All lights must be installed in dry conditions.
- Turn off electrical supply to the circuit before installation.
Wall Floodlight
This product must be installed in dry conditions by a qualified electrician. Turn off electrical supply to circuit before installation.
Specification | Standard |
---|---|
Location | Exterior |
Class | Class II |
IP rating | IP56 |
Driver required | No |
Fire rating | N/A |
Cable length | N/A |
Bulb type | GU10 (AR111) |
Max wattage | 16W |
Bulb included | No |
Switched | No |
Dimmable | Bulb dependent |
Rated voltage | 220V - 240V |
Rated frequency | 50-60Hz |
Included Components:
- Anchor x3
- Wall screw x3
- Mounting base x1
- Lamp body x1
- Glass lens with gasket x1
- Brass collar x1
Installation Instructions:
- Remove the grommet and cut off the tip.
- Put the grommet back in its place and push the wires through it. Make sure the gasket is attached to the mounting base.
- Drill three 6mm holes and set the anchors to attach the mounting base to the wall.
- Consult a qualified electrician to make the electrical connections.
- Use the grub screws provided to attach the light to the mounting ring.
- Screw the ring onto the mounting base.
- Unscrew the brass collar and remove the glass lens. Insert the bulb.
- Once the bulb is connected, replace the glass lens with the thicker side of the rubber gasket facing the bulb.
- Important: Ensure the brass collar is tightened all the way, as this is necessary for the IP rating of the light.
Safety Notes:
- Lights should only be installed by a qualified electrician.
- All lights must be installed in dry conditions.
- Turn off electrical supply to the circuit before installation.
IP68 Waterproof Straight Connector
This product must be installed in dry conditions by a qualified electrician. Turn off electrical supply to circuit before installation.
Specification | Details |
---|---|
Location | Exterior |
IP rating | IP68 |
Fire rating | No |
Included Components:
- Connector x1
- Grommet x2
Note: Swap the grommets when using armoured cable.
Installation Instructions:
- Connect the wires using the waterproof terminal.
- Screw the clamps on.
- Hide the connector and cable, for example, underground.
IP68 Waterproof Split T Connector
This product must be installed in dry conditions by a qualified electrician. Turn off electrical supply to circuit before installation.
Specification | Details |
---|---|
Location | Exterior |
IP rating | IP68 |
Fire rating | No |
Included Components:
- Connector x1
- Grommet x3
Note: Swap the grommets when using armoured cable.
Installation Instructions:
- Connect the wires using the waterproof terminal.
- Screw the clamps on.
- Hide the connector and cable, for example, underground.