Formula 65 LED CT Emergency Lighting Fixture

Beghelli S.p.A.

Installation and Technical Manual

General Information & Specifications

Product Name: Formula 65 LED CT

Manufacturer: Beghelli S.p.A.

Address: Via Mozzeghine 13/15, località Monteveglio 40053 Valsamoggia (BO), ITALY

Contact: Tel. +39 051 9660411, Fax +39 051 9660444, Toll-Free 800 626626

Website: www.beghelli.com

Operating Temperature: -10°C to 45°C

Power Supply: 230V - 50Hz

Ingress Protection: IP65

Certifications: UKCA, CE, ISO 14001, ISO 9001

WEEE Symbol: [Waste Electrical and Electronic Equipment symbol]

Dimensions

The fixture has the following approximate dimensions:

Installation and Wiring

Battery Connector Options

Various battery connector codes are available, including:

Cable Entry: Suitable for cables with a diameter of Ø 16-20mm.

Basic Autonomy Setting (1h-3h) without App

The autonomy can be set by connecting the battery AFTER cutting a specific wire. A 1-hour autonomy is achieved with the wire intact, and a 3-hour autonomy with the wire cut.

Important Note: The autonomy selection made via the App takes priority over circuit settings.

Wiring Diagrams

Wiring with Infinity Mode Deactivated

SA (Standard Autonomy): Wiring connections for Neutral (N), Live (L), L2, and N2 terminals.

SE (Emergency): Wiring connections for Neutral (N), Live (L), L2, and N2 terminals.

Optional Central Unit: Connections can be made to the optional Central unit cod. 20151 (for SA or SE modes).

General Wiring Precautions:

Wiring with Infinity Mode Activated

SA-SE (Standard Autonomy - Emergency): Wiring connections for N, L, L2, and N2 terminals.

Schema 2.1 (SA-SE): The fixture enters emergency mode due to: absence of general emergency power (CableCom network) OR absence of local lighting.

Schema 2.2 (SA-SE): The fixture enters emergency mode due to: absence of general emergency power (CableCom network).

Caution: SA luminaires can only be set to SE mode via the App (using smartphone flash on the lamp or Wi-Fi with Central CableCom Connect). When Infinity mode is active, terminals N2 and L2 must always be connected as shown in schemas 2.1 or 2.2.

Technical Specifications & Battery Options

The following table details available battery connector options and their specifications:

Battery Connector Code Type Voltage Current COS φ LEDs Battery Type Autonomy Options
19290SE230V 50Hz180mA0.0732 LEDLife 6.4V 1.5Ah1h, 1.5h, 2h, 3h, 8h
19291SE230V 50Hz180mA0.0732 LEDLife 6.4V 1.5Ah1h, 1.5h, 2h, 3h, 8h
19292SE230V 50Hz180mA0.0732 LED2x Life 6.4V 1.5Ah1h, 1.5h, 2h, 3h, 8h
19293SE230V 50Hz180mA0.0732 LED2x Life 6.4V 1.5Ah1h, 1.5h, 2h, 3h, 8h
19294SA230V 50Hz180mA0.11532 LEDLife 6.4V 1.5Ah1h, 1.5h, 2h, 3h, 8h
19295SA230V 50Hz180mA0.11532 LED2x Life 6.4V 1.5Ah1h, 1.5h, 2h, 3h, 8h
19296SA230V 50Hz180mA0.11532 LED2x Life 6.4V 1.5Ah1h, 1.5h, 2h, 3h, 8h

Note: For autonomy management, refer to the table. With Infinity mode activated and wired as per scheme 2.1, autonomy is infinite when the CableCom network (N-L+) is present.

Expansion Modules

The fixture can be expanded with the following modules:

These modules are SELV (Safety Extra Low Voltage).

Configuration and Commands

Configuration Options

The fixture can be configured for various settings:

Commands

Available commands include:

Configuration Methods

1. AT (without APP and without Central Unit)

Default Settings:

Jumper Settings: Can be used for some configurations.

QR Code ID: Preset by the QR code ID; not modifiable.

2. Use with B.connect App

Procedure:

  1. Open the B.connect App (available on the App Store and Google Play).
  2. Access lamp configuration via the "luminaire" menu.

Lamp Response:

QR Code: Each device has a unique QR code for identification.

App Positioning: For optimal B.connect App coverage, position the lamp within a maximum distance of 50cm (e.g., ensuring good light signal).

3. Centralized Action (AT + CENTRALE CABLECOM CONNECT (cod. 20151) + APP

Features:

Note: With the CableCom Connect control unit (cod. 20151), all configurations and commands can be sent remotely via the "nuBe" cloud.

Automatic Tests and LED Signals

Automatic Tests Periodicity

Even-numbered lamps perform the autonomy test one week after odd-numbered lamps. (Even: 0, 2, ..., 8, A, C, E; Odd: 1, 3, ..., 9, B, D, F).

LED Signals

App Communication and Warnings

Opening Communication from App

To open communication from the app, remove and reapply power for less than 3 seconds. The communication remains possible for 2 hours, and the LED flashes orange for 1 minute to signal this state.

Functional Test and STOP Functional Test can be controlled by the B.connect App at any time without needing to open communication with the device.

Warnings and Guarantee

This device is intended solely for its designed purpose. Any other use is considered improper and potentially dangerous.

The rechargeable battery and LED source are non-replaceable. For any repairs, contact an authorized technical service center and request the use of original spare parts.

Failure to adhere to these conditions may compromise the safety of the device.

Caution: Electric shock hazard.

Models: CT Formula 65 LED, CT, Formula 65 LED, 65 LED, LED

File Info : application/pdf, 2 Pages, 2.01MB

PDF preview unavailable. Download the PDF instead.

Mont n n vod - Formula 65 LED CT

References

QuarkXPress(R) 13.0.1 Acrobat Distiller 22.0 (Macintosh)

Related Documents

Preview Beghelli Formula 65 LED AT Emergency Lighting Installation and Operation Manual
Comprehensive guide for the Beghelli Formula 65 LED AT emergency lighting fixture, covering installation, configuration, operation with the B.connect app, and troubleshooting. Details include autonomy settings, LED signals, and safety warnings.
Preview Beghelli Completa LED CT Emergency Luminaire Installation and Operation Guide
Comprehensive guide for the Beghelli Completa LED CT emergency luminaire, covering installation, wiring, autonomy settings, and operational modes including Infinity mode and app control.
Preview Beghelli UP LED CT Emergency Lighting Installation and Operation Manual
Comprehensive guide for the Beghelli UP LED CT emergency lighting system, covering installation, wiring, configuration, and operation with or without the B.connect app and CableCom Connect central unit.
Preview Beghelli Completa LED TR Emergency Luminaire Installation and Technical Guide
Installation and technical guide for the Beghelli Completa LED TR emergency LED luminaire. Details IP ratings (IP40, IP42, IP66), wiring, model specifications, operation, and safety warnings.
Preview Beghelli Logica LED LG Emergency Lighting Fixture - Installation and Technical Manual
A comprehensive guide to the Beghelli Logica LED LG emergency lighting fixture, covering installation, wiring, technical specifications, LED status indicators, and safety warnings. This manual provides essential information for installers and maintenance personnel.
Preview Beghelli MICRODOT TR Emergency Light Installation and Settings Guide
Detailed installation and configuration guide for the Beghelli MICRODOT TR emergency LED lighting fixture. Covers dimensions, wiring, jumper settings, technical specifications, and safety warnings.
Preview Beghelli BS100 Regolabile RD LED Luminaire Installation and Operation Manual
Comprehensive guide for the Beghelli BS100 Regolabile RD LED luminaire, covering installation, wiring, power adjustment, and safety precautions. Includes multilingual instructions and technical specifications.
Preview Beghelli Inverter Universale AT: Installation and Settings Guide
Comprehensive guide to installing and configuring the Beghelli Inverter Universale AT emergency lighting conversion kit, including wiring diagrams, technical specifications, and operational settings.