Beghelli Logica LED LG Emergency Lighting Fixture
Installation and Technical Manual
Product Overview
The Beghelli Logica LED LG is an emergency lighting fixture designed for safety and reliability. It features LED illumination and various operational modes, suitable for different installation requirements.
Manufacturer: Beghelli S.p.A.
Address: Via Mozzeghine 13/15 - 40053 Loc. Monteveglio - Valsamoggia (BO), Italy
Website: www.beghelli.com
Contact: Tel. +39 051 9660411, Fax +39 051 9660444, Toll-free: 800 626626
Installation and Wiring
The following diagrams illustrate the installation and wiring procedures for the Logica LED LG fixture.
Diagram A: General View
This diagram shows the Logica LED LG fixture, a person performing installation, and the Beghelli website address.
Diagram B: Connection Terminals
Illustrates connection terminals with associated product codes: cod. 12175, cod. 12176, cod. 12177, and cod. 12180.
Diagram C: Internal Components
Depicts the internal layout of the fixture, showing connections to a control unit (12100) and a remote control (12101).
Diagram D: Mounting and Cable Entry
Shows the fixture being mounted. It indicates a cable entry point designed for cables with a diameter of 16-20mm.
Diagram E: Technical Specifications Table
Provides technical details for various models:
Model | Current (mA) | Power Factor (l) | LED Type | Lumens (Normal) | Lumens (Emergency) | Lumens (Standby) | Battery Type | Battery Capacity | Duration (2h) | Duration (4h) | Duration (6h) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
12182 SE | 25mA | >0,83 | 2x15 LED 0,5W | 750lm | 450lm | 350lm | Pb 6V 4Ah | - | 2h | - | 4h | 6h |
12183 SE | 25mA | >0,83 | 2x15 LED 0,5W | 900lm | 550lm | 450lm | Pb 6V 4Ah | - | 1,5h | - | 3h | 4h |
12184 SE | 25mA | >0,83 | 2x15 LED 0,5W | 1100lm | 750lm | 550lm | Pb 6V 4Ah | - | 1h | - | 2h | 3h |
12185 SA/PS | 45mA | >0,92 | 2x15 LED 0,5W | 750lm | 450lm | 350lm | NiMH 7,2V 2,5Ah | - | 2h | 4h | 6h | |
12186 SA/PS | 55mA | >0,92 | 2x15 LED 0,5W | 900lm | 550lm | 450lm | NiMH 7,2V 2,5Ah | - | 1,5h | 3h | 4h | |
12187 SA/PS | 60mA | >0,92 | 2x15 LED 0,5W | 1100lm | 750lm | 550lm | NiMH 7,2V 2,5Ah | - | 1h | 2h | 3h | |
12184S SE | 25mA | >0,83 | 2x15 LED 0,5W | 1500lm | 900lm | 700lm | NiMH 7,2V 4Ah | - | 1h | 2h | 3h | |
12187S SA/PS | 65mA | >0,92 | 2x15 LED 0,5W | 1500lm | 900lm | 700lm | NiMH 7,2V 4Ah | - | 1h | 2h | 3h |
Note: Lumens values are approximate. Battery types include Lead-acid (Pb) and Nickel-Metal Hydride (NiMH).
Diagram F: Wiring Configurations
Shows wiring for different modes: SA (Standby/Automatic), SE (Standby/Emergency), PS (Permanent/Standby). Connections are made to terminals P1, N1, P, N, D, A, and 230V power supply (L-N).
Diagram G: Operational Timing
Indicates timing related to operation, possibly standby duration or test cycles, with values like 24h, < 1h, 1/2h, 3h.
Diagram H: LED Module Installation
Illustrates the process of inserting the LED module into the fixture in two steps.
Diagram I: Multi-Fixture Installation
Shows multiple fixtures being installed, indicating an IP40 protection rating.
Automatic Test System
The fixture incorporates an automatic test system with the following periodicity:
- Functional Test (30 seconds): Every 28 days.
- Autonomy Test (1 hour): Every 26 weeks.
Even-numbered lamps perform their autonomy test one week after odd-numbered lamps. To initiate specific functions shown in diagrams, cycle the power (turn off and on) when the red LED indicator is lit.
LED Signal Indicators
The fixture uses LED indicators to display its status:
- Fixed Green: Battery is charged.
- Flashing Green: Battery is charging.
- One Red Flash: Battery duration error.
- Two Red Flashes: Lighting LED error.
- Three Red Flashes: Battery is disconnected.
Warnings and Guarantee
Please adhere to the following important warnings and guarantee conditions:
- This device is intended solely for its designed purpose. Any other use is considered improper and dangerous.
- The rechargeable battery and the LED source are non-replaceable components.
- For any repairs, contact an authorized technical service center and ensure only original spare parts are used. Failure to comply with these conditions may compromise the safety of the device.