This document provides information on the JABLOTRON JA-110N-DIN Bus Power Supply Module PG for DIN rail mounting. The product is a component within the JABLOTRON system, featuring a PG output relay switch suitable for controlling lighting, fans, and other devices. Installation should be performed by a trained technician holding a valid certificate from an authorized distributor.
Installation
⚠️ Electrical appliances must only be connected by a trained technician.
Always switch off the power when connecting the module to the system bus.
- Install the module on the DIN rail.
- Connect the bus cable to the terminals (1).
- Test the module's function by pressing the button (4). When the module is powered on, the red RELAY LED (2) lights up.
- Connect the controlled device to the output terminals (5).
Note: If communication is lost, the yellow STATUS LED (3) indicates this condition, and after 60 seconds, the relay enters a resting state.
Figure 1: Product External Parts Description
- 1 - Bus terminals
- 2 - Relay LED indicator
- 3 - Status LED indicator
- 4 - Learning/Manual Trigger Button
- 5 - Relay terminals
System Registration and Settings
Depending on the control panel type, use the recommended software or application. Refer to the control panel manual.
Technical Specifications
Parameter | Value |
---|---|
Power | From central unit bus 12 V (9-15 V) |
Quiescent Current Consumption (Relay OFF) | 5 mA |
Maximum Current Consumption (Relay ON) | 45 mA |
Relay Contact Load: (Galvanically and safely isolated from the bus) | |
Maximum Switching Voltage | 250 V AC / 24 V DC |
Resistive Load (cos q = 1) | max. 16 A |
Inductive, Capacitive Load (cos φ = 0.3) | max. 6 A |
Halogen Lighting | max. 1000 W |
DC Current | 384 W |
Minimum DC Switching Output Power | 0.5 W |
Power Loss | 1.6 W |
- Power Loss for Central Unit Heating | 1.9 W |
Diameter of Connected Wires | max. 2 x 1.5 mm²; 1 x 2.5 mm² |
Environment | Indoor general |
Operating Temperature Range | -10 °C to +40 °C |
Average Operating Humidity | 75 % RH, non-condensing |
Dimensions | 18 x 90 x 64 mm (according to EN 60715) |
Weight | 65 g |
Certification Body | Trezor Test sro (No. 3025) |
Complies With | EN 50130-4, EN 55032, EN IEC 62368-1, EN IEC 63000 |
Compliance and Declarations
JABLOTRON a.s. hereby declares that the JA-110N-DIN product is in compliance with the relevant harmonisation legislation of the Union: Directive No.: 2014/35/EU, 2014/30/EU, 2011/65/EU, when used as intended. The original of the conformity assessment can be found at www.jablotron.com under Downloads.
Disposal Information
Note: Correct disposal of this product will help to save valuable resources and prevent potential negative effects on human health and the environment, which could otherwise arise from improper waste handling. Please return the product to the retailer or contact your local municipality for more information on the nearest designated collection point.
Further Information
For an electronic version of this document (available in other languages) or an installation version for JA-100, scan the QR code.