Overview
This document provides technical specifications and installation guidance for the JABLOTRON JA-110N-DIN Bus Power Supply Module, designed for DIN rail mounting. The module is part of the JABLOTRON system and features a PG output relay capable of controlling external devices such as lighting or fans.
This document has been machine translated from its original English version. For any ambiguities or discrepancies, please refer to the original English document. For errors or further questions, contact technical support.
Installation
⚠️ Warning: Electrical apparatus must only be connected by a trained technician.
Always switch off the power when connecting the module to the system bus.
- Mount the module on the DIN rail.
- Connect the bus cable to the terminals (1).
- Test the module's function by pressing the button (4). The red RELAY LED (2) lights up when the module is powered on.
- Connect the controlled device to the output terminals (5).
Note: If communication is lost, the yellow STATUS LED (3) indicates this condition. After 60 seconds, the relay switches to standby mode.
Product External Parts Description (Figure 1)
Figure 1 illustrates the external components of the JA-110N-DIN module:
- 1: Bus terminals for connecting to the system bus.
- 2: Red LED indicator for trigger status.
- 3: Yellow LED indicator for fault or communication status.
- 4: Button for learning new devices or manual trigger operation.
- 5: Relay terminals for connecting the controlled device.
Registration and System Settings
Depending on the type of control panel used, follow the recommended software or application procedures. Refer to the specific control panel's manual for detailed instructions.
Technical Specifications
Parameter | Value |
---|---|
Power Source | From central unit bus 12 V (9-15 V) |
Quiescent current consumption (relay OFF) | 5 mA |
Maximum current consumption (relay ON) | 45 mA |
Relay contact load (galvanically and safely separated from the bus) | |
Maximum switching voltage | 250 V AC / 24 V DC |
Resistive load (cos φ = 1) | max. 16 A |
Inductive, capacitive load (cos φ = 0.3) | max. 6 A |
Halogen lighting | max. 1000 W |
DC current | 384 W |
Minimum DC-coupled output | 0.5 W |
Power loss | 1.6 W |
Power consumption for control panel heating | 1.9 W |
Connected conductor diameter | max. 2 x 1.5 mm²; 1 x 2.5 mm² |
Environment | Indoor general |
Operating temperature range | -10 °C to +40 °C |
Average operating humidity | 75% RH, non-condensing |
Dimensions | 18 x 90 x 64 mm (according to EN 60715) |
Weight | 65 grams |
Certification body | Trezor Test sro (No. 3025) |
Complies with | EN 50130-4, EN 55032, EN IEC 62368-1, EN IEC 63000 |
Declaration of Conformity
JABLOTRON a.s. hereby declares that the product JA-110N-DIN complies with the relevant Union harmonisation legislation: Directive No: 2014/35/EU, 2014/30/EU, 2011/65/EU, if used as intended. The original of the conformity assessment is available at www.jablotron.com under Downloads.
Environmental and Disposal Information
Note: By disposing of this product correctly, you save valuable resources and prevent potential negative effects on human health and the environment, which could otherwise arise from improper waste disposal. Please return the product to the retailer or contact your local authority for more information on the nearest collection point.
Further Information
For an electronic version of this document (available in other languages) or a JA-100 installation version, scan the attached QR code.