Product Features
The Resistex Miks spotlight is designed for adjustable orientation and low luminance applications. It features a sleek design suitable for various interior lighting needs.
Safety and Maintenance
Safety Notes
Important: Never work on the fixture when it is live. Installation must be performed by a qualified professional installer in strict compliance with all applicable electrical standards and regulations. Be aware of the risk of electrostatic discharges (ESD Norm) and handle the product with necessary precautions. Always observe the provided notes and follow the mounting steps carefully.
Maintenance Instructions
Do not use any chemicals or abrasive products for cleaning the fixture. It is recommended to keep these installation instructions for future dismantling or maintenance procedures. For additional information regarding Resistex luminaires, please consult the official website at www.resistex-sa.com. Resistex cannot be held responsible for any misuse of the product.
Installation Steps
Step 1: Prepare the Opening
Cut a circular opening in the ceiling with a precise diameter of 69 mm (+/- 1 mm). A cutting template is typically provided to ensure accuracy.
Step 2: Insert the Fixture
Carefully insert the main body of the Miks spotlight into the prepared ceiling opening. [arrow-up]
Step 3: Secure the Fixture
Rotate the fixture to engage its internal locking mechanism or spring clips, securing it firmly within the ceiling cutout. [circular-arrow]
Step 4: Prepare the Wire Connector
The fixture is equipped with an integrated, user-friendly wire connector. Open the connector housing to access the terminals. [arrow-right]
Step 5: Connect the Wiring
Insert the mains supply wires (Live, Neutral, and Ground) into the appropriate terminals within the connector. Ensure correct polarity and secure connection.
Step 6: Close the Connector
Close the connector housing securely. The terminals are clearly marked for Live (L), Neutral (N), and Ground connections, facilitating correct wiring.
Step 7: Engage Spring Clips
The spotlight features spring-loaded clips. Push the fixture further into the ceiling opening; the clips will automatically deploy and hold the fixture in place.
Step 8: Final Connection Check
Verify that all electrical connections are secure and that the fixture is properly seated in the ceiling. A visual guide is provided, indicating the correct electrical connection (✔️) and highlighting potential incorrect connections (❌) to ensure safe operation.
Step 9: Final Installation
The Resistex Miks recessed spotlight is now fully installed and ready for use.
Product Information and Certifications
Model: Miks
Version: V1.1 - 09.22
Features: Adjustable orientation, low luminance.
Manufacturer: Resistex Exploitation
Address: 11 Quai de la Banquière CS 80010, 06730 Saint-André-de-la-Roche, France
Contact: www.resistex-sa.com | Tél. 04 93 276 276 | Fax 04 93 276 280 | contact@resistex-sa.com