MASTECH MS2302 Earth Resistance Tester

SKU: MS2302CBGLO

Document: Quick Start Guide

Manufacturer: MGL Group

Brand: MASTECH

Certifications: CAT III 300V, CE, EAC, Intertek

Warranty: 1 Year Limited Warranty

Revision: July 2021 Rev. 2.0

Important Safety Information

⚠️ Please pay special attention when using this test and measurement instrument. Improper usage may cause electric shock and damage the equipment.

  • Use proper measurement category (CAT), voltage, and amperage rated probes, test leads, and adapters for the measurement.
  • Do not use or store the device around explosive gas, vapor, or under high temperature and humidity.
  • When handling test probes and crocodile clips, keep your fingers behind the physical guard.
  • Examine the measuring test leads before use. If any part of the insulation is deteriorated (even partially), replace them with proper functional test leads.
  • Connect the common test lead before the live test lead and remove the live test lead before the common test lead.
  • Before measuring current, ensure the instrument has available fuses and disconnect the power supply to the circuit being tested.
  • Remove batteries if the device is not used for an extended period or stored at temperatures above 45°C to prevent battery leakage damage.

Specifications

Measurement Range Resolution Accuracy
Earth Ground Resistance 0~29.99 Ω 0.01 Ω ±(2% + 6)
30~99.9 Ω 0.1 Ω ±(3% + 3)
100~999 Ω 1 Ω ±(3% + 3)
1.00~4.00 kΩ 10 Ω ±(3% + 3)
Measuring Voltage to Earth AC 0~200V (50Hz/60Hz) 0.01V ±(2% + 4)

Included test leads: Green-10m, Red-15m, Black-5m.

Measurement Procedures

Battery Installation

To power the device, batteries must be installed. Open the battery compartment cover, insert the required batteries, and then securely close the cover.

Voltage Measurement (~VE)

To measure voltage:

  1. Connect the test leads to the appropriate terminals on the MS2302 (e.g., E and ~VE).
  2. Connect the other ends of the test leads to the circuit you wish to measure voltage from.
  3. The measured voltage will be displayed on the device screen.

Earth Resistance Measurement (2-Pole Method)

This method is used for measuring earth ground resistance.

  1. Connection: Connect the device's 'E' terminal to the earth ground electrode. Connect the device's 'P/S' or 'C/H' terminal to the same earth ground electrode.
  2. Measurement: Press the 'MEASURE' button. The device will display the earth resistance. The calculation shown is RX = Re - re, where 'Re' is the resistance of the earth electrode and 're' is the resistance of the test lead.

Diagram Description: Shows the device connected via two leads to a single earth ground point, often depicted with a house symbol and an earth rod.

Earth Resistance Measurement (3-Pole Method)

This method provides a more accurate measurement of earth ground resistance.

  1. Connection: Connect the device's 'E' terminal to the earth ground electrode. Connect the device's 'P/S' terminal to an auxiliary earth stake (P). Connect the device's 'C/H' terminal to a second auxiliary earth stake (C). Ensure the stakes are properly driven into the ground at appropriate distances.
  2. Measurement: Press the 'MEASURE' button. The device will display the earth resistance. The calculation shown is RX = Re - re, where 'Re' is the resistance of the earth electrode and 're' is the resistance of the test lead.

Diagram Description: Shows the device connected via three leads to the main earth ground electrode and two auxiliary earth stakes (P and C) driven into the ground.

Company Information

For support and inquiries, MGL Group operates globally:

  • EMEA: MGL EUMAN S.L., C/ Picu Castiellu, Parcelas i1-i4 33163, Argame Morcín, Asturias, Spain. Tel: +34 985-08-18-70, Email: cs.emea@mgl-intl.com
  • USA: MGL AMERICA, INC., 2810 Coliseum Centre Drive, Ste. 100 Charlotte, North Carolina 28217 USA. Tel: +1 833-533-5899, Email: cs.na@mgl-intl.com
  • United Kingdom: MGL GROUP U.K. LIMITED, 14 Weller St, London, SE1 1QU, UK. Tel: +34 985-08-18-70, Email: cs.uk@mgl-intl.com
  • Mexico & LATAM: MGL LATAM S.A DE CV, Colonia Industrial Vallejo Del. Azcapotzalco 02300, Mexico D.F. Tel: +1 833-533-5899, Email: cs.latam@mgl-intl.com
  • APAC: MGL APPA Corporation, Flat 4-1, 4/F, No. 35, Section 3 Minquan East Road, Taipei, Taiwan. Tel: +886 2-2508-0877, Email: cs.apac@mgl-intl.com
Models: MS2302, Earth Resistance Tester

File Info : application/pdf, 2 Pages, 3.51MB

PDF preview unavailable. Download the PDF instead.

700019218 QSG MS2302CBGLO V2.0 20211208更新 Adobe PDF library 15.00 Adobe Illustrator(R) 24.0

Related Documents

Preview MS2302 Digital Earth Resistance Tester: Operating Instructions and Specifications
Comprehensive operating instructions and technical specifications for the Mastech MS2302 Digital Earth Resistance Tester. Learn how to perform earth voltage and resistance measurements safely and effectively.
Preview Mastech MS5203 Digital Insulation Tester Quick Start Guide
Concise guide for the Mastech MS5203 Digital Insulation Tester, covering essential safety precautions, detailed specifications, and step-by-step operating instructions for voltage, resistance, and insulation measurements. Includes regional contact information.
Preview Mastech MS2308 Earth Resistance Tester Quick Start Guide
A quick start guide for the Mastech MS2308 Earth Resistance Tester, detailing its specifications, usage, and safety precautions.
Preview MASTECH MS2108 AC/DC Clamp Meter Quick Start Guide
A concise quick start guide for the MASTECH MS2108 AC/DC Clamp Meter, detailing safety precautions, technical specifications, and basic usage instructions for measuring voltage, current, resistance, capacitance, and frequency.
Preview Mastech MS5201 Digital Insulation Tester Quick Start Guide
Concise Quick Start Guide for the Mastech MS5201 Digital Insulation Tester. Learn how to safely measure AC/DC voltage, resistance, and insulation resistance with this CAT II/III rated device. Includes specifications and operating instructions.
Preview MASTECH MS8268 Digital Multimeter Quick Start Guide
A concise quick start guide for the MASTECH MS8268 Digital Multimeter, providing essential safety information, detailed specifications, and step-by-step usage instructions for common measurements.
Preview MASTECH MS8211D Pen-type Digital Multimeter Quick Start Guide
A quick start guide for the MASTECH MS8211D pen-type digital multimeter, providing essential safety information, technical specifications, and basic operational instructions for voltage, current, resistance, and logic testing.
Preview Mastech MS8902B Non-Contact AC Voltage Detector Quick Start Guide
Quick start guide for the Mastech MS8902B Non-Contact AC Voltage Detector, providing essential safety information, usage instructions, and specifications for electrical testing.