Safety Precautions
Important: Special attention must be paid when using this test and measurement instrument, as improper usage may cause electric shock and damage to the equipment.
- Use probes, test leads, and adapters with the proper measurement category (CAT), voltage, and amperage ratings.
- Do not use or store the device near explosive gas, vapor, or in high temperature and humidity environments.
- When handling test probes and crocodile clips, keep fingers behind the physical guard.
- Examine test leads before use. If insulation is deteriorated (even partially), replace them with proper functional test leads.
- Connect the common test lead before the live test lead, and remove the live test lead before the common test lead.
- Before measuring current, ensure the instrument's fuses are available and disconnect the power supply to the circuit being tested.
- Remove batteries if the device is not used for an extended period or stored above 45°C to prevent damage from battery leakage.
Specifications
Function/Range | Resolution | Accuracy | |
---|---|---|---|
DC Voltage (V=) | 400mV, 4V, 40V, 400V, 1000V | 0.1mV, 1mV, 10mV, 100mV, 1V | ±(0.7%+2) to ±(0.8%+2) |
AC Voltage (V~) | 4V, 40V, 400V, 750V | 1mV, 10mV, 100mV, 1V | ±(0.8%+3) to ±(1.0%+3) |
DC Current (A=) | 400µA, 4000µA, 40mA, 400mA, 10A | 0.1µA, 1µA, 10µA, 0.1mA, 10mA | ±(1.2%+3) to ±(2.0%+5) |
AC Current (A~) | 400µA, 4000µA, 40mA, 400mA, 10A | 0.1µA, 1µA, 10µA, 0.1mA, 10mA | ±(1.5%+5) to ±(3.0%+7) |
Resistance (Ω) | 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ | 0.1Ω, 1Ω, 10Ω, 100Ω, 1kΩ, 10kΩ | ±(1.2%+2) to ±(2.0%+5) |
Capacitance (F) | 4nF, 40nF, 400nF, 4µF, 40µF, 200µF | 1pF, 10pF, 100pF, 1nF, 10nF, 0.1µF | ±(3.0%+3) to ±(5.0%+5) |
Frequency (Hz) | 10Hz, 100Hz, 1000Hz, 10kHz, 100kHz, 200kHz | 0.001Hz, 0.01Hz, 0.1Hz, 1Hz, 10Hz, 100Hz | ±(2.0%+5) |
Duty Cycle (Hz%) | 0.1% to 99.9% | 0.1% | ±(2.0%+2) |
Note: Specifications are subject to change without notification.
Safety Ratings: CAT II 1000V, CAT III 600V
Basic Usage Examples
To measure DC Voltage (V=):
- Connect the black test lead to the COM terminal.
- Connect the red test lead to the VΩHz terminal.
- Turn the dial to the V= position.
- Connect the test leads across the DC voltage source.
- Read the voltage on the display (e.g., 12.38 V=).
To measure AC Voltage (V~):
- Connect the black test lead to the COM terminal.
- Connect the red test lead to the VΩHz terminal.
- Turn the dial to the V~ position.
- Connect the test leads across the AC voltage source.
- Read the voltage on the display (e.g., 230.6 V~).
To measure DC Current (A=) in mA/µA range:
- Connect the black test lead to the COM terminal.
- Connect the red test lead to the mA/µA terminal.
- Turn the dial to the A= position.
- Connect the multimeter in series with the circuit.
- Read the current on the display (e.g., 2.53 A).
To measure DC Current (A=) in 10A range:
- Connect the black test lead to the COM terminal.
- Connect the red test lead to the 10A terminal.
- Turn the dial to the A= position.
- Connect the multimeter in series with the circuit.
- Read the current on the display (e.g., 2.53 A).
To measure AC Current (A~) in mA/µA range:
- Connect the black test lead to the COM terminal.
- Connect the red test lead to the mA/µA terminal.
- Turn the dial to the A~ position.
- Connect the multimeter in series with the circuit.
- Read the current on the display (e.g., 2.53 A).
To measure AC Current (A~) in 10A range:
- Connect the black test lead to the COM terminal.
- Connect the red test lead to the 10A terminal.
- Turn the dial to the A~ position.
- Connect the multimeter in series with the circuit.
- Read the current on the display (e.g., 2.53 A).
To measure Resistance (Ω):
- Connect the black test lead to the COM terminal.
- Connect the red test lead to the VΩHz terminal.
- Turn the dial to the Ω position.
- Connect the test leads across the resistor (ensure power is off).
- Read the resistance on the display (e.g., 380.6 Ω).
To measure Capacitance (F):
- Connect the black test lead to the COM terminal.
- Connect the red test lead to the VΩHz terminal.
- Turn the dial to the F position.
- Connect the test leads across the capacitor (ensure it is discharged).
- Read the capacitance on the display (e.g., 27.01 µF).
To measure Frequency (Hz):
- Connect the black test lead to the COM terminal.
- Connect the red test lead to the VΩHz terminal.
- Turn the dial to the Hz position.
- Connect the test leads to the signal source.
- Read the frequency on the display (e.g., 60.58 Hz).
To measure Transistor hFE:
- Turn the dial to the hFE position.
- Insert the transistor into the appropriate hFE socket (PNP or NPN).
- Read the hFE value on the display (e.g., 100).
Company Information
MGL Group
- EMEA: MGL EUMAN S.L., C/ Picu Castiellu, Parcelas i1-i4 33163, Argame Morcín, Asturias, Spain. Email: cs.emea@mgl-intl.com
- USA: MGL AMERICA, INC., 2810 Coliseum Centre Drive, Ste. 100 Charlotte, North Carolina 28217 USA. Email: cs.na@mgl-intl.com
- United Kingdom: MGL GROUP U.K. LIMITED, 14 Weller St, London, SE1 1QU, UK. Email: cs.uk@mgl-intl.com
- Mexico & LATAM: MGL LATAM S.A DE CV, Colonia Industrial Vallejo Del. Azcapotzalco 02300, Mexico D.F. Email: cs.latam@mgl-intl.com
- APAC: MGL APPA Corporation, Flat 4-1, 4/F, No. 35, Section 3 Minquan East Road, Taipei, Taiwan. Email: cs.apac@mgl-intl.com