The JA-110P product is part of the JABLOTRON system. It allows for the detection of human movements inside buildings. Its detection characteristics can be modified using an alternative lens. The detector installation must be carried out by a qualified technician, holding a valid certificate issued by an authorized distributor.
Installation
⚠️ Warning: Always disconnect the power before connecting the detector to the bus.
- Open the detector cover (by pressing tab – 5). Avoid touching the PIR sensor inside, as you might damage it.
- Remove the PCB – it is held by tab 3.
- Drill holes for screws and cable in the plastic base. The recommended installation height for the detector is 2.5 m above the floor.
- Insert the bus cable and fix the plastic base to the wall using screws (vertically, with the cover tab facing downwards).
- Reinsert the printed circuit board and connect the bus cables to the terminals, then register the detector according to the control panel installation manual. Finally, close the detector cover.
Figure 1: Detector opening and description of internal and external parts.
The figure shows two views of the JA-110P detector. View I illustrates how to open the detector housing by pressing a tab (labeled 5). View II shows the internal components and the rear of the detector. The internal printed circuit board (PCB) is visible, with connections and components. A separate diagram on the right shows the connection terminals labeled "CC-BUS", "+U", "A", "B", "GND", and other components numbered 7 through 11, including LED indicators, bus terminals, production code, tamper contact, and the PIR sensor.
- 1 – holes for installation on a flat wall
- 2 – holes for installation in a corner
- 3 – printed circuit board tab
- 4 – holes for installation in a corner
- 5 – cover tab
- 6 – red LED indicator – activation
- 7 – yellow LED indicator – default
- 8 – digital bus terminals
- 9 – production code
- 10 – tamper contact
- 11 – PIR sensor
System Enrollment and Parameters
According to the control panel type, use the recommended software or application – see the control panel manual.
Technical Specifications
Specification | Value | Operating Environment | Value |
---|---|---|---|
Power | from the control panel bus, 12 V DC (8...15 V) | General indoor use | |
Current consumption in standby mode | 5 mA | Operating temperature range | -10 °C to +40 °C |
Current consumption for cable choice (maximum) | 10 mA | Average operating humidity | 75% RH, non-condensing |
Recommended installation height | 2.5 m above the floor | Certification body | Trezor Test sro (no. 3025), KIWA Nederland BV |
Detection angle / detection coverage | 110 degrees / 12 m (with standard lens) | Complies with | EN50131-1, EN50131-2-2, EN50130-4, EN55032, EN 50581, T 031 |
Dimensions | 60 x 98 x 52 mm | Recommended screw | 2x Ø 3.5 x 40 mm (countersunk head) |
Weight | 75 g | ||
Classification | Security grade 2 / Environmental class II (according to EN 50131-1) |
Compliance and Declarations
JABLOTRON a.s. hereby declares that the JA-110P product complies with the European Union harmonization legislation: Directives No. 2014/30/UE and 2011/65/UE, if used in accordance with its intended purpose. The original conformity assessment is available at www.jablotron.com, Downloads section.
Environmental Note
Note: Proper disposal of this product will help preserve valuable resources and prevent potential negative effects on human health and the environment, which could result from improper waste management. Please return the product to the retailer or contact your municipality to find the nearest collection point.
Further Information
For an electronic version of this document (available in other languages) or an installation version in JA-100 format, scan the QR code.