JA-110P PIR Bus Motion Detector
This document has been automatically translated from the original English. In case of any doubt or uncertainty, please consult the original document. If you find any errors or have questions, please contact Technical Support (contact details are at the end of this document).
The JA-110P product is a component of the JABLOTRON system. It is used for detecting human motion indoors. Its detection characteristics can be modified using an alternative lens. The detector must be installed by a qualified technician with a valid certificate issued by an authorized distributor.
Installation
[Warning] Always switch off the detector before connecting it to the bus.
- Open the detector cover (by pressing the tab – 5). Avoid touching the internal PIR sensor, as it could be damaged.
- Remove the PCB: it is held by tab 3.
- Drill holes for the screws and cable in the plastic base. The recommended installation height for the detector is 2.5 m above the floor.
- Insert the bus cable and fix the plastic base to the wall using screws (vertically, with the cover tab facing downwards).
- Reinsert the printed circuit board (PCB) and connect the bus cables to the terminals. Then, register the detector according to the control panel installation manual. Finally, close the detector cover.
Fig. 1: Detector opening and description of internal and external parts.
Figure 1 shows the JABLOTRON JA-110P detector. Part I illustrates the detector's exterior with numbered points indicating installation holes and a cover tab. Part II shows the internal components and connection points. The numbered labels are:
- 1 – Flat wall installation holes
- 2 – Corner installation holes
- 3 – PCB mounting tab
- 4 – Corner installation holes
- 5 – Cover tab
- 6 – Red LED indicator (activation)
- 7 – Yellow LED indicator (fault)
- 8 – Digital bus terminals
- 9 – Production code
- 10 – Tamper contact
- 11 – PIR sensor
Registration and Configuration
Depending on the control panel type, use the recommended software or application – consult the control panel manual.
Technical Specifications
Power Supply | From the control panel bus, 12 V DC (8...15 V) |
Current Consumption (standby mode) | 5 mA |
Current Consumption (cable selection, max.) | 10 mA |
Recommended Installation Height | 2.5 m above floor |
Detection Angle / Detection Coverage | 110 degrees / 12 m (with standard lens) |
Dimensions | 60 x 98 x 52 mm |
Weight | 75 grams |
Classification | Security Grade 2 / Environmental Class II (according to EN 50131-1) |
Operating Environment | Indoor general |
Operating Temperature Range | -10 °C to +40 °C |
Average Humidity | 75% RH, non-condensing |
Certification Body | Trezor Test sro (No. 3025), KIWA Nederland BV |
Complies with | EN50131-1, EN50131-2-2, EN50130-4, EN55032, EN 50581, T 031 |
Recommended Screw | 2x Ø 3.5 x 40 mm (countersunk head) |
Compliance and Disposal
JABLOTRON a.s. hereby declares that the JA-110P product complies with the relevant Union harmonization legislation: Directives No. 2014/30/EU and 2011/65/EU, provided it is used as intended. The original declaration of conformity can be found at www.jablotron.com, Downloads section.
[Recycling Symbol] Note: Disposing of this product correctly will help save valuable resources and prevent potential negative effects on human health and the environment that could arise from improper waste management. Return the product to the distributor or contact your local authority for more information on the nearest designated collection point.
For an electronic version of this document (available in other languages) or an installation version for JA-100, scan the attached QR code. [QR Code]