JA-110P Bus PIR Motion Detector
Introduction
This document is machine-translated from the English original. In case of any uncertainty or doubt, please refer to the original version of the document. If you encounter any errors or have further questions, please contact technical support (contact details are provided at the end of the document).
The JA-110P is part of the JABLOTRON system. It is designed for detecting human motion in indoor areas of buildings. Its detection characteristics can be modified using an alternative lens. The detector must be installed by a qualified professional who holds a valid certificate issued by an authorized distributor.
Installation
[Warning] Always switch off the power supply before connecting the detector to the bus.
- Open the detector cover (by pressing the tab – 5). Avoid touching the inside of the PIR sensor – it may be damaged.
- Remove the PCB – it is held by tab 3.
- Drill the holes for screws and the cable in the plastic base. The recommended installation height for the detector is 2.5 m above the floor.
- Insert the bus cable and fix the plastic base to the wall with screws (vertically, with the cover tab facing downwards).
- Replace the PCB, connect the bus cables to the connectors, and then register the detector according to the control panel installation manual. Finally, close the detector cover.
Figure 1: Product Components
Figure 1 illustrates the detector's construction and components. View I shows the exterior of the JA-110P motion detector. View II reveals the internal printed circuit board (PCB) with numbered connection points and indicators.
- 1 - holes for mounting on a flat wall
- 2 - holes for corner mounting
- 3 - PCB mounting tab
- 4 - holes for corner mounting
- 5 - cover tab
- 6 - red LED indicator - activation
- 7 - yellow LED indicator - fault
- 8 - digital bus connectors
- 9 - production code
- 10 - tamper sensor
- 11 - PIR sensor
Registration and Settings
Depending on the control panel type, use the recommended software or application – see the control panel manual.
Technical Specifications
Power | From the control panel bus, 12 V DC (8...15 V) |
Standby current consumption | 5 mA |
Current consumption with cable selection (maximum) | 10 mA |
Recommended installation height | 2.5 meters above the floor |
Detection angle / detection coverage | 110 degrees / 12 m (with standard lens) |
Dimensions | 60 x 98 x 52 mm |
Weight | 75 grams |
Classification | Security Grade 2 / Environmental Class II (according to EN 50131-1) |
Operating environment | General indoor |
Operating temperature range | -10 °C to +40 °C |
Average operating humidity | 75% relative humidity, non-condensing |
Certifying body | Trezor Test sro (no. 3025), KIWA Nederland BV |
Complies with | EN50131-1, EN50131-2-2, EN50130-4, EN55032, EN 50581, T 031 |
Recommended screw | 2x Ø 3.5 x 40 mm (countersunk head) |
Declarations and Notes
JABLOTRON a.s. hereby declares that the JA-110P product, when used as intended, complies with the relevant EU harmonisation legislation: Directives 2014/30/EU and 2011/65/EU. The original copy of the conformity assessment is available on the JABLOTRON website – in the Downloads section.
Note on Disposal: Proper disposal of the product helps conserve valuable resources and prevents potential negative impacts on human health and the environment, which could otherwise result from improper waste management. Please return the product to your retailer or contact your local municipality to find the nearest designated collection point.
An electronic version of this document (available in other languages) or an installed version is available in the JA-100 version. Scan the accompanying QR code.