Jablotron JA-110P Bus PIR Motion Detector
This document has been machine translated from the original English version. In case of any ambiguities or doubts, please refer to the original document version. If you find any errors or have additional questions, please contact technical support (contact information can be found at the end of this document).
The JA-110P product is a component of the JABLOTRON system. It is used for detecting human motion inside buildings. Its detection characteristics can be changed using an alternative lens. The detector must be installed by a qualified technician with a valid certificate issued by an authorized distributor.
Installation
Always disconnect power before connecting the detector to the bus.
- Open the detector cover (by pressing the lug – 5). Avoid touching the IR detector inside – you may damage it.
- Remove the PCB – it is held by lug 3.
- Drill holes for screws and cable in the plastic base. The recommended installation height for the detector is 2.5 m above the floor.
- Insert the bus cable and attach the plastic base to the wall using screws (vertically, with the cover facing down).
- Reinsert the PCB and connect the bus cables to the terminals, then register the detector according to the control panel installation instructions. Finally, close the detector cover.
Figure 1: Detector product opening and description of internal and external parts.
- 1 – holes for wall mounting
- 2 – holes for corner mounting
- 3 – PCB mounting lug
- 4 – holes for corner mounting
- 5 – cover lug
- 6 – red LED indicator – activation
- 7 – yellow LED indicator – fault
- 8 – digital bus terminals
- 9 – factory code
- 10 – tamper contact
- 11 – PIR motion detector
System Registration and Setup
Depending on the control panel type, use the recommended software or application – see the control panel’s installation manual.
Technical Specifications
Power supply | Bus of the control panel, 12 V DC (8...15 V) | Classification | Security Grade 2 / Environmental Class II (according to EN 50131-1) |
Current consumption in standby mode | 5 mA | Operating environment | General purpose indoor |
Current consumption for cable selection (maximum) | 10 mA | Operating temperature range | -10 °C to +40 °C |
Recommended installation height | 2.5 m above the floor | Average operating humidity | 75% relative humidity, without condensation |
Detection angle / detection coverage | 110 degrees / 12 m (with standard lens) | Certification body | Trezor Test sro (No. 3025), KIWA Nederland BV |
Dimensions | 60 x 98 x 52 mm | Conforms to | EN50131-1, EN50131-2-2, EN50130-4, EN55032, EN 50581, T 031 |
Weight | 75 g | Recommended screw | 2x Ø 3.5 x 40 mm (countersunk head) |
The company JABLOTRON a.s. hereby declares that the JA-110P product complies with the relevant harmonized Union legislation: Directives No. 2014/30/EC, 2011/65/EC, when used as intended. The original Declaration of Conformity can be found on the website www.jablotron.com – Downloads section.
Note: Proper disposal of this product helps save valuable resources and prevent any potential negative impact on human health and the environment that could result from improper waste handling. Please return the product to your dealer or contact your local authorities for more information on the nearest collection point.
JABLOTRON a.s. | Pod Skalkou 4567/33 | 46601 Jablonec n. N. | Czech Republic | www.JABLOTRON.com
Model: MLT54716