Jablotron JA-110P Bus PIR Motion Detector

This document was machine-translated from the original English version. In case of any ambiguity or doubt, please refer to the original document. If you encounter errors or have further questions, please contact technical support (contact information is at the end of this document).

The JA-110P product is a component of the JABLOTRON system. It is used for detecting human motion in indoor building spaces. Its detection characteristics can be altered by using an alternative lens. Immunity to false alarms is available in two options. The detector has an impulse response (reports only its triggering). The detector should be installed by a trained technician holding a valid certificate from an authorized dealer. This product is compatible with JA-101K, JA-102K, JA-103K, JA-106K, JA-107K.

Mounting

The detector can be installed on a wall or in a room corner. Its field of view should not contain objects that rapidly change temperature (e.g., electric heaters, gas appliances) or move (e.g., curtains hanging over a radiator), nor pets. It is not recommended to install the detector facing windows or spotlights, or in locations with excessive airflow (near fans, heat sources, air conditioning outlets, leaky doors, etc.). There should be no obstructions in front of the detector that could hinder its view.

Diagram 1: Mounting Holes

Illustration shows:

  • 1 - Holes for mounting on a flat wall
  • 2, 4 - Holes for mounting in a corner
  • 3 - Retaining clip
  • 5 - Cover latch
  1. Open the detector cover (by pressing the latch - 5). Avoid touching the internal PIR sensor (11) as you might damage it.
  2. Remove the circuit board – it is held by clip 3.
  3. Drill holes for the circuit board screws and the cable in the plastic base. The recommended mounting height for the detector is 2.5 m above the floor.
  4. Feed the bus cable through and fix the plastic base to the wall with screws (vertically, with the cover latch facing downwards). Important: Always switch off the power supply when connecting the detector to the system bus.
  5. Reinsert the circuit board and connect the bus cables to the terminals (8).
  6. Proceed according to the instructions for mounting the central control units.

Internal Settings

The detector's characteristics can be set in the Components list window of the F-Link software. When you are at the detector's location, open the Internal Settings option to access a dialog window for making settings:

  • Immunity Level: Determines immunity to false alarms. The Standard immunity level (factory setting) combines basic immunity with a fast reaction. The Increased level offers higher immunity, but the detector's reaction is slower. To comply with standard EN 50131-2-2:2021, the Standard level must be used.
  • Motion Detection LED: Allows the user to disable the motion detection indicator via a red LED.

Detection Characteristics

The standard lens supplied with the JA-110P detector covers a range of 110 degrees / 12 m. The range is monitored by 3 beams – see the following illustration.

Diagram 2: Detection Patterns

These detection characteristics apply to standard PIR immunity.

The characteristics can be altered by using an alternative lens:

Lens TypeDescription
JS-7910Equipped only with the upper beam, monitoring 120 degrees / 12 m and not covering the ground (can eliminate the motion of small pets on the floor). With this lens, the detector corresponds to the JA-110P PET type.
JS-7904For long corridors – with a working range of up to 20 m. Increased interference immunity cannot be used with this lens! When using this lens, the detector does not comply with standard EN50131-2-2:2021.
JS-7902Vertical curtain – it does not monitor an area but forms a detection wall (can be used to create a barrier and report its breach). When using this lens, the detector does not comply with standard EN50131-2-2:2021.

Note: If a lens is replaced with a different type, test whether the detector monitors the area correctly (an incorrectly installed lens can cause detection errors).

Technical Parameters

The detector's terminals and components are illustrated below:

Diagram 3: Detector Terminals and Components

Illustration shows:

  • 6 - Red LED indicator for detector activation
  • 7 - Yellow fault indicator
  • 8 - Digital bus terminals
  • 9 - Serial number
  • 10 - Tamper contact
  • 11 - PIR sensor
ParameterSpecification
Power SupplyFrom the bus 12 V DC (8...15 V)
Quiescent Current Consumption5 mA
Maximum Current Consumption10 mA
Recommended Installation Height2.5 m above the floor
Detection Angle / Detection Range110° / 12 m (with standard lens)
Dimensions60 x 98 x 52 mm
Weight75 g
ClassificationSecurity Grade 2 / Environment Class II (according to EN 50131-1)
Operating EnvironmentIndoor areas generally
Operating Temperature Range-10 °C to +40 °C
Average Operating Humidity75% RH, non-condensing
Certification BodyTrezor Test s.r.o. (No. 3025), Kiwa Nederland b.v.
Recommended Screw2x Ø 3.5 x 40 mm (countersunk head)

Compliance and Disposal

Basic Procedure:

  1. Upon powering up the device, the yellow LED (7) will repeatedly blink, indicating that the module has not been registered in the system.
  2. Launch the F-Link software, select the desired position in the Components list window, and start the registration mode by clicking the Register option.

Declarations of Conformity

JABLOTRON a.s. hereby declares that the JA-110P product is in compliance with the relevant Union harmonization legislation: Directives No.: 2014/30/EU, 2011/65/EU, when used as intended. The original Declaration of Conformity can be found at www.jablotron.com - Downloads section.

The product complies with the following standards: EN 50131-1, -2-2, EN 50130-4, EN 55032, EN IEC 63000, T 031.

The product bears the CE and UKCA marks, indicating compliance with relevant EU and UK regulations.

Disposal Information

[WEEE Disposal Symbol] Proper disposal of this product helps to save valuable resources and avoid potential negative impacts on human health and the operating environment, which could otherwise arise from improper waste handling. Please return the product to the dealer or inquire with your local municipal authority for the nearest collection point.

PDF preview unavailable. Download the PDF instead.

ja-110p de mlt51216 Eduard Feifer Adobe PDF Library 25.1.51

Related Documents

Preview Jablotron JA-110P PIR Motion Detector Installation and Specifications
Comprehensive guide to the Jablotron JA-110P PIR motion detector, covering installation, internal settings, detection characteristics, and technical specifications. Learn how to set up and optimize the detector for various applications.
Preview JA-110P PIR Motion Detector Installation and Technical Guide
Comprehensive guide for the JABLOTRON JA-110P PIR motion detector, covering installation, internal adjustments, detection characteristics, technical specifications, and compliance information.
Preview JABLOTRON JA-121PW Bus Combined PIR+MW Motion Detector Installation and Technical Guide
Comprehensive guide to the JABLOTRON JA-121PW Bus Combined PIR+MW Motion Detector, covering installation, settings, function testing, and technical specifications for security systems.
Preview Jablotron JA-151F Wireless Flood Detector User Manual
User manual for the Jablotron JA-151F wireless flood detector, covering installation, maintenance, and technical specifications. This device is designed for detecting water leaks in indoor environments.
Preview Jablotron Security Systems for Home and Business
Discover Jablotron's reliable and scalable security solutions for homes and businesses. Explore features like easy operation, comprehensive protection against intrusion, fire, gas, and water damage, and smart home integration.
Preview Jablotron JA-151E Draadloze Taglezer voor Sectiebesturing - Handleiding
Gedetailleerde handleiding voor de Jablotron JA-151E draadloze taglezer. Leer hoe u dit apparaat installeert, configureert en gebruikt voor sectiebesturing in Jablotron beveiligingssystemen. Inclusief knopfuncties, indicaties, technische specificaties en conformiteitsverklaringen.
Preview JA-151E Wireless Tag Reader for Section Control - JABLOTRON Datasheet
Technical datasheet for the JABLOTRON JA-151E wireless tag reader. This document details installation, configuration, button functions, acoustic and visual indications, battery replacement, and technical specifications for controlling alarm system sections.
Preview JA-151F Wireless Water Detector - Jablotron
User manual and technical specifications for the Jablotron JA-151F wireless water detector. Learn about installation, battery replacement, and product features.