JA-110P PET - Wireless PIR Motion Detector with Pet Immunity
This document is a machine translation from the original English. For any ambiguities or doubts, please refer to the original document. If you find errors or have questions, contact technical support (contact information is at the end of this document).
The JA-110P PET is a wired device within the JABLOTRON system, designed for detecting human movement in building interiors. It features a modified detection pattern and basic immunity to pets (animals up to 25 kg and 40 cm tall), mitigating false alarms from small animals on the floor. The detector operates with an impulse response and occupies a single system address. Installation requires a qualified technician with a valid certificate from an authorized distributor.
Installation
⚠️ When connecting the detector to the bus, always turn off the system power.
- Open the detector cover by pressing the cover tab (5). Avoid touching the IR detector inside (11) – you may damage it.
- Remove the printed circuit board – it is held by the tab (3).
- Drill holes for screws and cable in the plastic base. The recommended installation height for the detector is 2 m above the floor.
- Insert the bus cable and attach the plastic base to the wall with screws (vertically, cover facing down).
- Insert the printed circuit board back and connect the cables to the terminals (8).
- Follow the instructions for installing the control panel.
Figure 1: Detector Cover and Internal/External Parts Description
The diagram shows two views (I and II) of the detector, illustrating how to open it and access the internal components.
External Parts:
- 1 – holes for mounting on a flat wall
- 2 – holes for mounting in a corner (at an angle)
- 3 – tab on the printed circuit board
- 4 – holes for mounting in a corner (at an angle)
- 5 – cover tab
Internal Components (Circuit Board):
- 6 – red LED – activation
- 7 – yellow LED – fault
- 8 – bus terminals
- 9 – factory code
- 10 – cover tamper sensor
- 11 – PIR detector
System Designation and Settings
Depending on the type of control panel, use the recommended software or application. Refer to the control panel user manual for details.
Technical Specifications
Power supply | from the control panel bus 12 V (8...15 V) | Classification | 2/II class. General indoor use (according to EN 50131-1) |
Current consumption (standby) | 5 mA | Operating environment | General indoor |
Current consumption (max) | 10 mA | Operating temperature range | -10 °C to +40 °C |
Recommended installation height | 2 m above floor | Average operating humidity | 75% relative humidity, without condensation |
Detection angle / detection zone | 90° / 12 m | Certification body | Trezor Test sro (No. 3025), KIWA Nederland bv |
Detection angle / detection zone (pet immunity) | 90° / 7 m | Also complies with | EN 50131-1, EN 50131-2-2, EN 50130-4, EN 55032, EN IEC 63000, T 031. |
Pet immunity | Up to 25 kg, 40 cm height | Recommended screw | 2x 3.5 x 40 mm (countersunk head) |
Dimensions | 60 x 98 x 52 mm | ||
Weight | 75 g |
Compliance and Disposal
CE UKCA [recycling symbol]
JABLOTRON a.s. hereby declares that the JA-110P PET complies with the current harmonisation legislation of the European Union: Directives No. 2014/30/EU, 2011/65/EU, provided it is used for its intended purpose. The original declaration of conformity can be found on the website www.jablotron.com - in the Downloads section.
Note: Proper disposal of this product helps conserve valuable resources and prevent any potential negative impact on human health and the environment that could result from improper waste handling. Please return the product to your dealer or contact your local authorities for information on the nearest collection point.
Scan the QR code to access the electronic version of this document (available in other languages) or the installation version for JA-100.