JABLOTRON JA-110P PET Bus PIR Motion Detector with Basic Pet Immunity

This document has been machine translated from the original English version. In case of any ambiguities or doubts, please refer to the original version of the document. If you encounter any errors or have further questions, please contact technical support (contact details are at the end of this document).

General Information

The JA-110P PET is a bus device within the JABLOTRON system, used for detecting the motion of people in buildings. Unlike the standard JABLOTRON 100 series PIR motion detectors, this detector features a modified detection characteristic and is equipped with basic pet immunity. The detector effectively eliminates the effects of movement by small animals on the floor (animals weighing up to approximately 25 kg and with a maximum height of 40 cm). It operates with a pulse reaction and takes a position within the system. Installation should be performed by a trained technician holding a valid certificate issued by an authorized distributor.

⚠ The detector only eliminates the effects of animal movement on the floor according to the detection characteristics. It is not suitable for monitoring areas where animals can move freely in height!

Installation

The detector can be installed on a wall or in a corner of a room. Ensure that the detector's field of view does not contain objects that rapidly change temperature (e.g., electric heaters, gas appliances) or move (e.g., curtains hanging above a radiator, robot vacuum cleaners). Although the detector is highly resistant to false alarms, it is not recommended to install it in locations with intense air circulation (near fans, air conditioning units, vents, unsealed doors, etc.). There should be no obstructions within the detector's field of view that would hinder its view into the monitored area.

The recommended installation height for the detector is 2 meters, with a maximum height of 2.2 meters.

Figure 1: Mounting Holes and Components

Figure 1 illustrates the mounting options and key components:

  1. Open the detector cover by pressing the cover tab (5). Avoid touching the PIR sensor inside (11) as this may cause damage.
  2. Remove the circuit board; it is held in place by a tab (3).
  3. Punch through the designated holes for screws and the cable in the plastic base. The recommended installation height for the detector is 2 meters above the floor.
  4. Insert the bus cable and attach the plastic base to the wall using screws (vertically, with the cover tab facing downwards).

⚠ When connecting the detector to the bus, always turn off the power to the system.

  1. Reinstall the circuit board and connect the cables to the terminals (8).

Figure 2: Detector Terminals and Indicators

Figure 2 shows the detector's terminals and indicators:

Basic Instructions for System Integration

Continue by following the control panel installation manual. Basic integration steps include:

Detector Settings and Testing

Notes on Registration and Settings

Setting Detector Properties

Open the F-Link software and navigate to the Devices tab. Click the Internal settings button next to the detector's position to open a dialog box where you can configure:

Testing Detectors

In service mode, the red LED indicator on the detector will signal every motion, irrespective of the settings configured in the detector's properties. Individual detector activations can also be monitored via the Diagnostics tab within the F-Link software.

Detection Characteristics

Figure 3: Detection Pattern

Figure 3 illustrates the detection characteristics of the JA-110P PET.

The detector is equipped by default with a lens covering a 90° angle and a range of up to 12 meters. In the white-shaded area of the diagram, the detector eliminates the effects of movement by small animals weighing up to approximately 25 kg and with a maximum height of 40 cm. The grey-shaded area represents the standard detection range.

The diagram shows:

Technical Specifications

ParameterSpecification
PowerFrom control panel bus, 12 V (8... 15 V)
Quiescent current consumption5 mA
Max current consumption10 mA
Recommended installation height2 m above floor
Detection angle / coverage90° / 12 m
Detection angle / coverage - pet immunity90° / 7 m
Dimensions60 x 98 x 52 mm
Weight75 g
ClassificationGrade 2 / Class II. indoor general (according to EN 50131-1)
Operating environmentIndoor general
Operating temperature range-10 °C to +40 °C
Average operating humidity75 % relative humidity, non-condensing
Certification bodiesTrezor Test s.r.o. (No. 3025), Kiwa Nederland b.v.
Also complies withEN 50130-4, EN 55032, EN IEC 63000, EN 50131-1, -2-2, T 031
Recommended screw2 x Ø 3.5 x 40 mm (countersunk head)

Compliance and Disposal

JABLOTRON a.s. hereby declares that the JA-110P PET is in conformity with the relevant EU harmonisation legislation: Directive No: 2014/30/EU, 2011/65/EU, when used as intended. The original Declaration of Conformity can be found at www.jablotron.com in the Downloads section.

Disposal Note: Proper disposal of this product helps conserve valuable resources and prevent potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste management. Please return the product to your retailer or contact your local authority for more information on your nearest designated collection point.

PDF preview unavailable. Download the PDF instead.

ja-110p-pet sv mmu55007 Jiří Kreisel Adobe PDF Library 25.1.97

Related Documents

Preview JABLOTRON JA-110P PET Bus PIR Motion Detector: Installation & Specifications
Comprehensive guide to the JABLOTRON JA-110P PET Bus PIR motion detector, covering installation procedures, technical specifications, detection characteristics, and pet immunity features for security systems.
Preview JA-110P PET PIR Motion Detector: Installation, Specs, and Overview
Detailed technical specifications, installation guide, and product overview for the JABLOTRON JA-110P PET PIR motion detector with basic animal immunity for bus systems. Includes compliance information and usage guidelines.
Preview JABLOTRON JA-110P PET Bus PIR Motion Detector Installation and Specifications
Comprehensive guide to the JABLOTRON JA-110P PET Bus PIR motion detector, covering installation, features, technical specifications, and pet immunity for security systems.
Preview JABLOTRON JA-110P PET Bus: PIR Motion Detector with Pet Immunity | Technical Specifications
Detailed technical specifications and installation guide for the JABLOTRON JA-110P PET Bus PIR motion detector. Features pet immunity, BUS system compatibility, and EN 50131-3 compliance for indoor security applications.
Preview Jablotron JA-110P PET Bus PIR Motion Detector Installation and Technical Guide
Comprehensive guide for the Jablotron JA-110P PET Bus PIR motion detector, detailing installation, features including pet immunity, technical specifications, and detection characteristics.
Preview Jablotron JA-110P PET Bus PIR Motion Detector: Installation and Technical Specifications
Comprehensive guide to the Jablotron JA-110P PET Bus PIR motion detector. Covers installation, system enrollment, detection characteristics including pet immunity, technical specifications, and compliance information.
Preview JA-110P PET Bus PIR Motion Detector with Pet Immunity - Technical Specifications and Installation
Detailed technical specifications and installation guide for the JABLOTRON JA-110P PET bus PIR motion detector, featuring basic pet immunity for home security systems.
Preview JABLOTRON JA-110P PET Bus PIR Motion Detector with Basic Pet Immunity
This document provides detailed information on the JABLOTRON JA-110P PET bus PIR motion detector, designed for indoor motion detection. It features basic immunity to small animals and is intended for installation by trained professionals. Includes technical specifications and installation guidance.