JABLOTRON JA-110P PET Bus PIR Motion Detector

JA-110P PET Bus PIR Motion Detector with Basic Pet Immunity

This document provides information on the JA-110P PET, a JABLOTRON system bus device used for detecting human movement indoors. It features modified detection characteristics and basic pet immunity, ignoring small animals on the floor (up to approximately 25 kg and a maximum height of 40 cm). The detector has a pulse reaction and integrates into the system. Installation must be performed by a trained technician with a valid certificate from an authorized distributor.

The detector specifically ignores the effects of animal movement on the floor based on its detection characteristics. It is not suitable for surveillance areas where animals may move freely at different heights.

Installation

The detector can be installed on a wall or in a room corner. Ensure the detector's field of view does not include objects that rapidly change temperature (e.g., electric heaters, gas appliances) or move (e.g., curtains over radiators, robot vacuum cleaners). While resistant to false alarms, avoid installing in locations with intense air circulation (near fans, air conditioning, ventilation grilles, unsealed doors). No obstacles should obstruct the detector's view of the protected area.

The recommended installation height is 2 m, with a maximum of 2.2 m.

Figure 1: Mounting points

Describes mounting holes for flat walls (1) and angled corners (2, 4), a PCB retention tab (3), and a cover release tab (5).

  1. Open the detector cover by pressing the cover tab (5). Avoid touching the internal PIR sensor (11) as it could be damaged.
  2. Remove the PCB by releasing the tab (3).
  3. Drill the screw holes and a cable hole in the plastic base. The recommended installation height is 2 m above the floor.
  4. Insert the bus cable and fix the plastic base to the wall with screws (vertically, with the cover tab facing downwards).
  5. Important: Always turn off the system when connecting the detector to the bus.
  6. Reinsert the PCB and connect the cables to the terminals (8).

System Enrollment

Follow the control panel installation manual.

  • Open F-Link software, select an unused position in the Devices tab, and click the 'Enroll' button to enter enrollment mode.
  • Click 'Scan/add new bus devices', select the detector, and double-click to confirm. The yellow LED will turn off.

Testing

Close the detector cover and test the detector's operation.

Notes

  • The detector can also be enrolled by entering its production code (9) into F-Link software. The code is found on the sticker below the barcode (e.g., 1400-00-0000-0001).
  • Enrollment can also be initiated by pressing the cover tamper sensor (10).
  • To comply with EN 50131-3, secure the cover tab (5) with the supplied screw.

Detector Properties Configuration

In F-Link software, navigate to the Devices tab and click the 'Internal settings' button for the detector's position to open a dialog where you can configure:

  • LED Motion Indication: Allows disabling the red motion indicator LED.

Detector Testing

When in service mode, the detector's red LED indicates each motion event, without reference to the detector's property settings. Individual detector activations can also be monitored in the Diagnostics tab in F-Link software.

Detection Characteristics

The detector is equipped with a lens covering 90° / 12 m as standard. The diagram illustrates detection zones:

Figure 3: Detection Characteristics

Illustrates the detection range, with a 90° field of view. The white zone indicates areas where movement from small animals (up to approx. 25 kg, 40 cm height) is ignored, while the grey zone shows standard detection up to 12 meters.

Figure 2: Detector Components

Identifies the red activation LED (6), yellow fault LED (7), bus terminals (8), production code sticker (9), cover tamper sensor (10), and PIR sensor (11).

Technical Specifications

ParameterValue
Power12 V (8–15 V) from control panel bus
Standby Current Consumption5 mA
Max. Current Consumption10 mA
Recommended Installation Height2 m above floor
Detection Angle / Coverage90° / 12 m
Detection Angle / Coverage (Pet Immunity)90° / 7 m
Dimensions60 x 98 x 52 mm
Weight75 grams
ClassificationGrade 2 / Class II indoor (according to EN 50131-1)
Operating EnvironmentGeneral indoor
Operating Temperature Range-10 °C to +40 °C
Operating Humidity75% RH, non-condensing
Certification BodyTrezor Test s.r.o. (no. 3025), Kiwa Nederland b. v.
Also Complies WithEN 50130-4, EN 55032, EN IEC 63000, EN 50131-1, -2-2, T 031
Recommended Screw2x Ø 3.5 x 40 mm (countersunk head)

Compliance and Disposal

JABLOTRON a.s. hereby declares that the JA-110P PET complies with the relevant European Union harmonization legislation: Directives No.: 2014/30/EU, 2011/65/EU, when used as intended. The original Declaration of Conformity can be found at www.jablotron.com – the Downloads section.

Note on Disposal: Disposing of this product correctly will help conserve valuable resources and prevent potential negative effects on human health and the environment, which might otherwise arise from improper waste handling. Return the product to the distributor or contact your local authority for more details on the nearest designated collection point.

PDF preview unavailable. Download the PDF instead.

ja-110p-pet es mmu54507 Jiří Kreisel Adobe PDF Library 25.1.97

Related Documents

PreviewJABLOTRON JA-110P PET Bus PIR Motion Detector Installation and Specifications
Comprehensive guide to the JABLOTRON JA-110P PET Bus PIR motion detector, covering installation, features, technical specifications, and pet immunity for security systems.
PreviewJablotron JA-110P PET Bus PIR Motion Detector Installation and Technical Guide
Comprehensive guide for the Jablotron JA-110P PET Bus PIR motion detector, detailing installation, features including pet immunity, technical specifications, and detection characteristics.
PreviewJABLOTRON JA-110P PET Bus PIR Motion Detector with Pet Immunity - Installation and Specifications
Comprehensive guide for installing and configuring the JABLOTRON JA-110P PET Bus PIR motion detector, including technical specifications, detection characteristics, and pet immunity features.
PreviewJA-110P PET Bus PIR Извещатель Движения Jablotron: Руководство и Характеристики
Подробное руководство по установке и эксплуатации извещателя движения JA-110P PET Bus PIR от Jablotron. Узнайте о его функциях, устойчивости к домашним животным и технических характеристиках для систем безопасности.
PreviewJABLOTRON JA-110P PET Bus PIR Motion Detector with Pet Immunity
Installation guide and technical specifications for the JABLOTRON JA-110P PET Bus PIR motion detector, featuring basic immunity to domestic animals. Learn about installation, setup, and features.
PreviewJABLOTRON JA-110P PET PIR Motion Detector with Pet Immunity - Installation and Features
Comprehensive guide to the JABLOTRON JA-110P PET PIR motion detector, covering installation, setup, technical specifications, and pet immunity features for enhanced security.
PreviewJABLOTRON JA-110P PET Bus PIR Motion Detector with Basic Pet Immunity
This document provides detailed information on the JABLOTRON JA-110P PET bus PIR motion detector, designed for indoor motion detection. It features basic immunity to small animals and is intended for installation by trained professionals. Includes technical specifications and installation guidance.
PreviewJA-110P PET Bus PIR Motion Detector with Pet Immunity - Technical Specifications and Installation
Detailed technical specifications and installation guide for the JABLOTRON JA-110P PET bus PIR motion detector, featuring basic pet immunity for home security systems.