JA-110P PIR Motion Detector for Buses
Introduction
This document was automatically translated from the original English version. In case of doubts or uncertainties, please consult the original document. If you find any errors or have other questions, contact technical support (contact details are at the end of this document).
The JA-110P product is a component of the JABLOTRON system. It is used for detecting human movement in indoor building environments. Its detection characteristics can be modified using an alternative lens. The detector must be installed by a trained technician with a valid certificate issued by an authorized distributor.
Installation
⚠️ Always disconnect power before connecting the detector to the bus.
- Open the detector cover (by pressing tab 5). Avoid touching the internal PIR sensor – you could damage it.
- Remove the PCB – it is secured by tab 3.
- Drill holes for the screws and the cable in the plastic base. The recommended installation height for the detector is 2.5 m above the floor.
- Insert the bus cable and fix the plastic base to the wall using screws (vertically, with the cover tab facing downwards).
- Reinsert the printed circuit board and connect the bus cables to the terminals. Then, register the detector according to the control panel installation manual. Finally, close the detector cover.
Product Opening and Internal/External Parts Description
Fig.1: Opening of the product and description of the internal and external parts of the product.
- 1 – holes for installation on a flat wall
- 2 – holes for corner installation
- 3 – PCB mounting tab
- 4 – holes for corner installation
- 5 – cover tab
- 6 – red LED indicator – activation
- 7 – yellow LED indicator – fault
- 8 – digital bus terminals
- 9 – production code
- 10 – anti-tamper contact
- 11 – PIR sensor
The diagram shows the detector's housing and the PCB with labeled terminals (U, A, B, GND) and components.
System Enrollment and Configuration
According to the control panel type, use the recommended software or application – consult the control panel manual.
Technical Specifications
Power | From the control panel bus, 12 V DC (8...15 V) | Operating environment | General indoor |
Current consumption in standby mode | 5 mA | Operating temperature range | -10 °C to +40 °C |
Current consumption for cable selection (max.) | 10 mA | Average operating humidity | 75% RH, non-condensing |
Recommended installation height | 2.5 m above floor | Certification body | Trezor Test sro (No. 3025), KIWA Nederland BV |
Detection angle / coverage | 110 degrees / 12 m (with standard lens) | Conforms to | EN50131-1, EN50131-2-2, EN50130-4, EN55032, EN 50581, T 031 |
Dimensions | 60 x 98 x 52 mm | Recommended screw | 2x Ø 3.5 x 40 mm (countersunk head) |
Weight | 75 g | ||
Classification | Security Grade 2 / Environmental Class II (according to EN 50131-1) |
Compliance and Disposal
JABLOTRON a.s. hereby declares that the JA-110P product is in compliance with applicable Union harmonization legislation: Directives No. 2014/30/EU, 2011/65/EU, provided it is used according to its instructions. The original Declaration of Conformity can be found at www.jablotron.com - Downloads Section.
Observation: Proper disposal of this product helps conserve valuable resources and prevent potential negative effects on human health and the environment that could arise from improper waste handling. Return the product to the reseller or contact the local authority for more information on the nearest collection point.
To obtain an electronic version of this document (available in other languages) or an installation version for JA-100, scan the QR code attached.