JABLOTRON JA-110A II Bus Internal Siren with Battery Backup
www.jablotron.com
Product Overview
This document is a translation from the original English version. For any ambiguities or unclear points, refer to the original version of the document. If you find errors or have further questions, contact technical support (contact details can be found at the end of this document).
The JA-110A II siren is part of the JABLOTRON system and is used for signaling alarms indoors. Pressing the siren's button can silence an active alarm, confirm presence in a room, or trigger a panic alarm (optional function). The siren occupies one position in the system. Installation must be performed by a trained technician holding a valid certificate issued by an authorized dealer.
Diagram Descriptions
Figure 1: Siren Disassembly Before Installation
Describes the process of removing the siren body from the plastic frame by pressing the side of the body (1) with a screwdriver, and then removing the center part by pressing four lugs marked with arrows (2).
Figure 2: Description of Internal Parts
- 1 - LED indicators
- 2 - Buttons
- 3 - Manufacturing number
- 4 - Button lugs
- 5 - Piezoelectric siren
- 6 - Bus connector
- 7 - Tamper detectors
- 8 - Battery connector for BAT-3V2-CR2
Installation
- Detach the siren body (buttons) from the plastic frame by pressing the side of the body (1) with a screwdriver, as shown in Figure 1.
- Remove the center part of the body (3) by pressing the four lugs marked with arrows (2).
- Thread the bus cable through the rectangular recess in the plastic base.
- Secure the plastic base to the chosen location with screws. If the siren uses a battery, place it under the upper edge of the plastic base as shown in Figure 1.
- Assemble the plastic frame onto the plastic base, which secures the battery in place.
System and Settings Alignment
Use the recommended software or application according to the control panel type – refer to the control panel user manual.
Technical Specifications
- Power
- 12 V DC (8...15 V) from the control panel bus
- Optional Backup Battery
- 3.2 V LiFePo4 CR2 0.4 Ah (Note: battery not included in delivery)
- Standby Current Consumption for Backup
- 5 mA
- Maximum Cable Current Consumption
- 120 mA
- LowBatt Status
- 2.9 V
- Siren Type
- Piezoelectric, 100 dB/m (±5 dB/m)
- Dimensions
- 80 x 80 x 35 mm
- Weight
- 92 grams
- Protection Class / Environmental Class
- Protection Class 2 / Environmental Class II (EN 50131-1)
- Operating Environment
- Indoors generally
- Operating Temperature Range
- -10 °C - +40 °C
- Average Operating Humidity
- 75% relative humidity, without condensation
- Certification Body
- Trezor Test sro (No. 3025)
- Complies with Standard
- EN 50131-1, EN 50131-4, EN 50130-4, EN 55032, EN 62368-1, EN 50581
- Recommended Screw
- 2x Ø 3.5 x 40 mm (countersunk head)
Compliance and Disposal
JABLOTRON a.s. hereby declares that the JA-110A II is in compliance with the relevant harmonisation legislation of the European Union: Directives No. 2014/35/EU, 2014/30/EU, 2011/65/EU. The original conformity assessment document can be found at www.jablotron.com – Downloads section.
Note: Proper disposal of this product helps conserve valuable natural resources and prevents potential negative effects on human health and the environment, which could otherwise result from improper waste handling. Return the product to your dealer or contact local authorities for information on the nearest collection point.