Introduction
This document provides information on the JABLOTRON JA-110A II internal siren, a component of the JABLOTRON alarm system designed for indoor use. It details installation procedures and technical specifications.
The JA-110A II siren is used for alarm signaling in indoor environments. Pressing a button on the siren can silence an ongoing alarm signal, confirm presence, or trigger a panic alarm (optional function). Installation must be performed by a trained technician with a valid certificate from an authorized distributor.
Installation
Siren Disassembly and Preparation
Figure 1: Disassembly of the siren before installation. This diagram illustrates how to separate the siren's main body from its base.
The disassembly process involves:
- Removing the siren body (buttons) from the plastic frame by pressing one side of the body (labeled '1' in the diagram) with a screwdriver.
- Removing the central frame part (labeled '3' in the diagram) by pressing the four tabs indicated by arrows (labeled '2' in the diagram).
Mounting and Wiring
The installation steps are:
- Pass the BUS cable through a designated rectangular recess in the plastic base.
- Fix the plastic base in the selected location using screws. If the siren uses a battery, place it under the upper part of the plastic base, as shown in Figure 1.
- Mount the plastic frame with the plastic base, which will secure the battery in place.
Internal Parts Description
Figure 2: Description of the product's internal parts. This diagram shows the numbered components within the siren.
- 1 - LED indicators
- 2 - Buttons
- 3 - Production number
- 4 - Button guides
- 5 - Piezoelectric siren
- 6 - Bus terminal
- 7 - Tamper sensors
- 8 - Battery connector for BAT-3V2-CR2
System Assignment and Configuration
Configuration depends on the control panel type. Use the recommended software or application. Consult the control panel manual for detailed instructions.
Specifications
Feature | Specification |
---|---|
Power | Control panel bus 12 V DC (8...15 V) |
Optional backup battery | 3.2 V LiFePo4 CR2 0.4 Ah (Note: battery not included) |
Quiescent current consumption for backup | 5 mA |
Maximum current consumption for cable selection | 120 mA |
LowBatt status | 2.9 V |
Alert device type | Siren |
Siren | Piezoelectric, 100 dB/m (±5 dB/m) |
Dimensions | 80 x 80 x 35 mm |
Weight | 92 g |
Classification | Security grade 2 / Environmental class II (EN 50131-1) |
Operating environment | Indoor general |
Operating temperature range | -10 °C to +40 °C |
Average operating humidity | 75% RH, non-condensing |
Certifying body | Trezor Test sro (No. 3025) |
Conforms to | EN 50131-1, EN 50131-4, EN 50130-4, EN 55032, EN 62368-1, EN 50581 |
Recommended screw | 2x Ø 3.5 x 40 mm (countersunk head) |