Product Overview
The JA-110A II is a bus-indoor siren that is part of the JABLOTRON system. It serves to indicate alarms indoors. By pressing a button on the siren, the ongoing alarm indication can be silenced, which can also confirm the presence of a person in the building or trigger a panic alarm (optional function). The siren is a system function and should be installed by a trained technician with a valid certificate from an authorized dealer.
Installation
Step 1: Remove the siren's housing (the buttons) from the plastic frame by pressing on one side of the housing (1.) with a screwdriver, as shown in Figure 1.
Step 2: Remove the middle part of the frame (3.) by pressing the 4 tabs marked by arrows (2.).
Step 3: Feed the BUS cable through a designated rectangular recess in the plastic base.
Step 4: Secure the plastic base with screws to the desired location. If the siren requires a battery, place it under the top of the plastic base as shown in Figure 1.
Step 5: Mount the plastic frame with the plastic base, which secures the battery in its position.
Figure 1: Dismantling the siren before installation.
Figure 2: Description of the product's internal parts: 1 – LED indicators; 2 – Buttons; 3 – Production number; 4 – Button tabs; 5 – Piezoelectric siren; 6 – Bus connector; 7 – Tamper sensors; 8 - Battery connector for BAT-3V2-CR2
System Assignment and Settings
Use the recommended software or application depending on the type of control panel – see the control panel manual.
Technical Data
Power: | From the central bus 12 V DC (8...15 V) |
Optional Backup Battery: | 3.2 V LiFePo4 CR2 0.4 Ah (Note: Battery is not included in the scope of delivery) |
Quiescent current consumption for backup: | 5 mA |
Maximum current consumption on cable selection: | 120 mA |
LowBatt Status: | 2.9 V |
Type of warning device: | Siren, piezoelectric, 100 dB/m (±5 dB/m) |
Dimensions: | 80 x 80 x 35 mm |
Weight: | 92 g |
Classification: | Security grade 2 / Environmental class II (EN 50131-1) |
Operating environment: | Indoor general |
Operating temperature range: | -10 °C to +40 °C |
Average humidity during operation: | 75% relative humidity, without condensation |
Certification body: | Trezor Test s.r.o. (No. 3025) |
Complies with: | EN 50131-1, EN 50131-4, EN 50130-4, EN 55032, EN 62368-1, EN 50581 |
Recommended screw: | 2x Ø 3.5 x 40 mm (countersunk head) |
Declarations and Notes
JABLOTRON a.s. hereby declares that the JA-110A II complies with the relevant harmonisation legislative provisions of the European Union: Directives No.: 2014/35/EU, 2014/30/EU, 2011/65/EU. The original Declaration of Conformity can be found at www.jablotron.com in the Downloads section.
Note: By properly disposing of this product, you save valuable resources and avoid possible negative impacts on health and the environment that could arise from improper disposal. Please return the product to the dealer or contact your local authority for more information on the nearest collection point.