The product is part of the JABLOTRON system. It is used for alarm notifications in a building. By pressing a button on the siren, the alarm notification (= confirmation that someone is in the building) can be acknowledged. The siren must be installed by a qualified technician with a valid certificate from an authorized distributor.

Important: Always connect the bus only when the system power is completely switched off.

  1. Remove the siren casing (buttons) from the plastic frame by pressing a side of the casing (1.) with a screwdriver, as shown in Fig. 1.
  2. Remove the middle part of the frame (3.) by pressing the 4 tabs indicated by the arrows (2.).
  3. Push the bus cable through the designated rectangular cutout in the plastic base.
  4. Fasten the plastic base with screws in the chosen location.
  5. Attach the plastic frame to the plastic base again.
  6. Connect the bus cable to the terminals (6) as shown in Fig. 2 and place the casing back into the plastic frame.

Note: The tamper sensors (7) must be positioned above the magnets in the plastic base.

Figure 1: Siren removal for installation. Shows how to detach the siren casing from the plastic frame using a screwdriver.

Figure 2: Internal view of the siren. Labels indicate: 1 - electronic latches, 2 - internal buttons, 3 - serial number, 4 - casing pins, 5 - piezo-electric siren, 6 - bus terminals, 7 - tamper sensor.

System Enrollment and Settings

Depending on the control panel type, use the recommended software or application. Consult the control panel manual for guidance.

Technical Specifications

Power Supply12 V DC bus (9...15 V)
Quiescent Current5 mA
Max Current30 mA
SirenPiezo-electric, 85 dB/m
Warning Device TypeIndoor, Type X
Dimensions80 x 80 x 28 mm
Acoustic Performance80 dB / 1 m
ClassificationSecurity Class 2 / Environmental Class II (according to EN 50131-1)
EnvironmentIndoor, general
Weight70 grams
Operating Temperature Range-10 °C to +40 °C
Average Operating Humidity75% RH, non-condensing
Certification BodyTrezor Test sro (No. 3025)
Complies withEN 50131-1, -4, EN 50130-4, EN 55032, EN IEC 62368-1, EN IEC 63000
Can be operated according toERC REC 70-03
Recommended Screw2x 3.5 x 40 mm (countersunk head)

Compliance and Disposal

JABLOTRON a.s. hereby declares that the JA-110A complies with the relevant European Union harmonization legislation: Directives No. 2014/30/EU, 2014/35/EU, 2011/65/EU, when used as intended. The original conformity assessment can be found on www.jablotron.com – Downloads section.

Disposal Notice: Proper disposal of this product saves valuable resources and prevents potential negative effects on human health and the environment that could arise from improper waste handling. Return the product to the dealer or contact your municipality for information on the nearest collection point.

For an electronic version of this document (available in other languages) or an installation version for JA-100, scan the accompanying QR-code (QR code excluded from output).

PDF preview unavailable. Download the PDF instead.

ja-110a leg nl from en origin mlp21817 Adobe PDF Library 25.1.97

Related Documents

Preview JA-110A Internal Bus Siren Installation and Specifications | JABLOTRON
Comprehensive installation guide and technical specifications for the JABLOTRON JA-110A internal bus siren. Learn about setup, features, and compliance for alarm systems.
Preview JABLOTRON JA-110A Internal Bus Siren Installation and Specifications
Installation guide and technical specifications for the JABLOTRON JA-110A internal bus siren, a component of the JABLOTRON security system. Includes safety and compliance information.
Preview JABLOTRON JA-110A II Bus Internal Siren: Installation Guide and Specifications
Comprehensive guide to installing and understanding the JABLOTRON JA-110A II bus internal siren, including technical specifications, compliance information, and mounting instructions.
Preview Jablotron JA-110A II Bus Internal Siren with Battery Backup - Installation and Technical Guide
Detailed guide for the Jablotron JA-110A II internal bus siren, including installation steps, component descriptions, technical specifications, and compliance information for Jablotron alarm systems.
Preview JABLOTRON JA-110A Internal Bus Siren Installation and Specifications
Detailed installation guide and technical specifications for the JABLOTRON JA-110A internal bus siren, a component of the JABLOTRON alarm system. Learn about its features, installation steps, and technical parameters.
Preview JABLOTRON JA-110A Bus Internal Siren: Installation Guide and Technical Specifications
A comprehensive guide for installing and configuring the JABLOTRON JA-110A bus internal siren. Includes step-by-step installation instructions, visual descriptions, technical specifications, and compliance information.
Preview JABLOTRON JA-110A II Bus Internal Siren: Installation and Specifications
Comprehensive guide to the JABLOTRON JA-110A II Bus internal siren with battery back-up, covering installation, technical specifications, and system integration for security applications.
Preview JABLOTRON JA-110A Internal Bus Siren: Installation and Technical Data
Comprehensive guide to installing and technical specifications for the JABLOTRON JA-110A internal bus siren, a key component for JABLOTRON alarm systems. Features installation steps, system registration, and detailed technical data.