DALSKÄR Wash-basin Mixer Tap
Product by IKEA
Installation Guidelines & Safety
ℹ️ Installation Note: This installation must be carried out in accordance with industry regulations, specifically "Säker Vatteninstallation" (Safe Water Installation).
⚠️ Safety First: Always switch off the main shut-off valve before changing or installing the mixer tap. ?
This product is certified under TG 1179 and KIWA 1913, meeting standards EN 817 and EN 1717.
RSK Number: 8430089
Technical Specifications
- Recommended Operating Temperature: Max. 60°C
- Maximum Operating Temperature: Max. 80°C
- Recommended Operating Pressure: 1-5 bar
- Maximum Operating Pressure: 0.5-10 bar
Tools and Parts
The following tools are typically required for installation:
- Wrench
- Allen key (provided, 121844)
- Coin (for aerator adjustment)
Included parts:
- 1x Allen key (121844)
- 2x Flexible hoses (110084)
- 1x Fixing screw (124405)
- 1x Mounting plate (10044928)
- 2x Fixing brackets (121845, 121846)
- 1x Fixing nut (10046279)
- 1x Aerator/Flow guide (124607)
- 1x Ceramic cartridge (10095582)
- 1x Handle (190555)
- 1x Handle screw (190556)
- Components for pop-up waste assembly (10097281)
Assembly Steps
Step 1: Prepare Faucet Body
Position the faucet body over the sink. Insert the flexible hoses (110084) and the fixing screw (124405) through the base of the faucet into the sink mounting hole.
Step 2: Secure Faucet to Sink
From underneath the sink, attach the fixing brackets (121845, 121846) and the mounting plate (10044928) to the fixing screw (124405). Tighten using the fixing nut (10046279) with the provided Allen key (121844) to secure the faucet firmly.
Step 3: Seal Surfaces
Seal the open surfaces around the faucet base with silicone sealant to prevent water from penetrating the worktop in case of leaks. Silicone sealant is not included.
The silicone sealant must be water- and mould-resistant and suitable for the installation, according to EN 15651-3, Class XS1.
Installation Hole Diameter: Ø 34 - 37 mm (Ø 1 3/8" - 1 7/16")
Maximum Worktop Thickness: Max. 50 mm (Max. 2")
Step 4: Connect Water Supply
Connect the flexible hoses (110084) to the water supply pipes. Ensure the pipe connection is flat and free from sharp edges.
⚠️ IMPORTANT! Do not tighten too hard: this can damage hoses/pipes and washers.
Note: Ensure correct hose connections are made. Incorrect connections are marked with an 'X'.
Step 5: Install Pop-up Waste Assembly
Install the pop-up waste assembly (10097281) into the sink drain hole.
- Insert the waste body into the sink drain.
- Secure the waste body from underneath with the provided nut.
- Connect the lift rod linkage (10044928) to the waste mechanism.
- Attach the overflow cover.
Before First Use & Maintenance
ℹ️ Before Use: Unscrew the aerator/flow guide (124607) with a coin. Allow water to run freely for a few minutes to flush out any debris. Then, screw the aerator/flow guide back into place until it stops.
⚠️ DO NOT OVER TIGHTEN the aerator/flow guide.
ℹ️ Maintenance: Check at regular intervals to ensure the installation is not leaking. ?