產品資訊

手冊中提到的符號

  • UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG (1)The manual includes necessary information regarding the safe usage and equipment maintenance and, before use, read through each section of the manual.
  • UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG (1)不閱讀說明書或不理解說明書中規定的設備使用方法會導致人身傷害和設備損壞。UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG (2)

超過VIEW

測試儀面板上的符號及其說明(圖 1)

UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG (3)

  1. Test pen L 1;
  2. Test pen L2;
  3. 卷tage 指示(LED);
  4. 液晶顯示;
  5. 高音量tage 指示;
  6. AC indication;
  7. 連續性指示;
  8. Polar indication;
  9. Rotary phase indication;
  10. RCD indication (LED);
  11. RCD test button;
  12. Flashlight/self-inspection button;
  13. HOLD mode/backlighl button;
  14. 手電筒
  15. Test pen cap;
  16. 電池蓋

液晶面板

圖 2 提供了 LCD 面板的詳細說明。

  1. 靜音模式指示;
  2. HOLD 模式指示;
  3. 低音量tage 電池指示;
  4. 卷tage 測量;
  5. 頻率測量;
  6. 直流電壓tag測量
  7. 交流電壓tage 測量;
  8. 卷tage indication (LCD segment code);
  9. 高音量tage 指示;
  10. 連續性指示;
  11. RCD指示;
  12. 旋轉相位指示UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG (4)

操作說明

測試儀操作說明及使用範圍

卷tage and continuity tester includes four models: UT18A, UT18B, UT18C, UT18D and UT18E, has such functions as AC/DC (including three-phase alternating current) voltage測量、三相交流相位指示、頻率測量、RCD測試、通斷測試、無電池供電情況下的簡單測試、自檢、靜音模式選擇、過壓tage 指示和低音量tage battery indication. In addition, the flashlight attached to the test pen provides convenient application in a dark environment. To protect tester and, more particularly, the tester user, the tester is equipped with protecting jacket. The tester should be put on a protective jacket after use and, preferably, placed inside tool kit so as to protect it against any damage. Never place the tester into your pocket.

該測試儀適用於家庭、工廠、電力部門等各種場合。

它具有以下特點:

  1. To protect against physical injury, ii is designed with a protective jacket.
  2. LED indication (UT1 BA/B/C/E);
  3. 液晶顯示卷tage和頻率顯示(UT18C/D/E);
  4. AC/DC measured up to 690V, UT18E can reach 1000V;
  5. 連續性測量;
  6. 標明三相交流電的相位關係;
  7. Both the buzzing and silent mode is optional.
  8. 無電池檢測(UT18A/B/C/E);
  9. 手電筒功能;
  10. 自檢功能;
  11. 低電量音量tage 指示和測量體積tage 超量程指示(當 UT1 BE 電池電量低時tage、無法測量,需要更換電池);
  12. RCD測試(UT18B/C/D/E);
  13. 自動待機。

安全注意事項

為防止人身傷害、觸電或火災,請特別注意以下事項:

  • 使用卷之前tage detector with audible indicator at locations with a high background noise level, it has to be determined whether the audible signal is perceptible.
  • 卷tage detectors are designed to be used by skilled persons and in accordance with safe methods of work.
  • 音量的不同指示信號tag偵測器(包括 ELV 限值指示)不得用於測量目的。
  • 測試前確保測試筆和測試儀器完好無損;
  • Be sure keep your hand only in contact with the handle while using the equipment.
  • 切勿在音量調節時使用設備tage超出範圍(參考技術規範參數)且在800V以上;
  • 使用前,請確保設備能正常工作;
  • 為保證測試儀正常工作,測量已知體積tage value in first.
  • 如果出現一個或多個功能故障或沒有功能指示,則無法再使用測試儀。
  • 切勿在潮濕條件下進行測試。
  • Display functions well only when the temperature ranges -15″+45″C and relative humidity is <85%.
  • 如果不能保證操作者的人身安全,必須對儀器進行維修。
    1. The safety would no longer be guaranteed in any of the following circumstances:
    2. Visible damage;
    3. Tester’s functions are inconsistent with the functions that it is supposed to have.
    4. It had been stored in inappropriate conditions for a long time.
    5. Subject to mechanical extrusion in transit.

卷tag測量

A Observe safety test regulations specified in item 3. Voltage gear of tester is composed of a line of LED or LCD segment codes, including 6V (IJT18D), 12V, 24V, 50V, 120V, 230V, 400V, 690V and 1000V (UT18E only). LED (or LCD segment code) would be lighted one after another along with increased voltage、極性LED(或LCD段碼)指示、AC LED(或LCD段碼)指示、開關LED(或LCD段碼)指示、RCD LED(或LCD段碼)指示、旋轉相位LED(或 LCD 段碼)指示和高音量tage LED(或 LCD 段碼)指示。

  1. Complete a self-check of tester before test. After pressing the flashlight key 5s, tester would perform ACIDC full range detection, accompanied by flashing LED (with the exception to RCD light) and blinking displayed LCD. If need to exit self-check, just touch the flashlight key. Connect two test pens to the conductor to be measured, select a known voltage 用於測量,如220V插座,並保證測量精度(見圖3)。 測試儀無法測量交直流電壓tage less than 5V and provides no accurate indication while measuring voltage 是 5Vac/dc。 照明連續性燈或交流燈或高音量tage 符號(UT18D)和蜂鳴器蜂鳴器正常。UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG (5)
  2. Tester would provide LED indication (UT18A/B), LED•LCD indication (UT18C/E ) and LCD indication (UT18D) while measuring AC or DC voltage. 高音量tage LED would be illuminated and buzzer beeps when the measured voltage 是超低音量tage (ELV) threshold. measured voltage 繼續增加並超過輸入保護 voltage (UT18A’B/C/D:750Vac/dC, UT18E: 1015Vac/dc) Of the tester, the corresponding LED would keep flashing (UT18A/B/C/E), LCD displays “OL’ (UT18C/D/E ) and the buzzer keeps beeping.
  3. 用於測量直流電壓tage, if L2 and Ll connected respectively to the positive and negative pole of the object to be measured, LED would indicate the corresponding voltage、LCD顯示音量tage, meanwhile the LED indicating positive pole would be illuminated, LCD displays “VDC” and, on the contrary, the LED indicating negative pole would be illuminated, LCD displays “-NDC”. If need to judge the positive and negative pole of the object to be measured, connect two test pens to the object to be measured randomly, the illuminating positive pole LED or LCD “+” on tester means the terminal connecting to L2 is the positive and the other connecting to Ll is the negative.
  4. 用於測量交流電壓tage, two test pens may be randomly connected to two ends of the object to be measured, AC LED would be illuminated ( “+” , “-” LED illuminate indicate AC at the same time, only for UT18E) LCD displays “VAC” while LED indicates the corresponding voltage值和LCD顯示對應的音量tage 值。

筆記: For measuring AC voltage, L and R phase inversion indication LED (UT18A/B/C/E) or L and R symbol (UT18D) would be illuminated, it means phase indication is unstable, L light (L symbol) or R light (R symbol) is illuminated, and even L and R light (L and R symbol) would be illuminated alternatively; L and R light (L and R symbol) would not provide correct and stable indication unless measunng three phase power system.

無電池檢測

The tester may perform simple detection while the battery runs out or not battery is provided. Connect two test pens to the object to be measured. When the object has a voltage higher than or equivalent to 50V AC/120V DC, high -voltage LED 將亮起,指示危險音量tage 並且LED會隨著音量的增加而逐漸變亮tage to be measured. The function is applicable only to UTI BAJB/C/E.

連續性測試

確認被測導體是否帶電,卷tag可採用測量方法測量體積tage at both ends of the conductor by using two test pens. Connect two test pens to the both ends of the object to be measured, if the resistance falls within continuity symbol ” (UT18D) would be illuminated, accompanied by continuous beeping buzzer; and if resistance falls within 100kQ—150kQ, continuity LED(LJTI 8N3/C)or continuity symbol “UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG 8 ” (UTI 8D)may or may not be illuminated and buzzer may or may not beep; if the resistance falls within LED(UTI 8E)or continuity symbol ” UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG 8” would be illuminated, accompanied by continuous beeping buzzer: if resistance falls within 60kQ—150kQ. continuity continuity symbol may or may not be illuminated and buzzer may or may not beep if resistance is >150kQ, continuity LED(UTI 8A/B/C/E) or continuity symbol “UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG 8” (UT18D) may not be illuminated and buzzer would not beep. Before any test, be sure the object to be measured red is not electrified.

旋轉測試(三相交流相位指示)

  • 測量必須按照第 3 項規定的安全測試規定進行。
  • ln the case Of strong electric field interference or strong radiation test phase sequence, the test results may be unstable.

R, L LED or L and R symbol indication is applicable for rotation test and the test is only applicable for a three-phase AC system.

  1. 三相電壓tage test range: 57VÄ400V (50Hzæ60Hz) (IOOV—400V only for UT18E).
  2. Hold the main body of tester (with finger holding handle), as shown in the following figure, connect test pen L2 to any phase and Ll to any of the remaining two phases.
  3. R or L LED would be illuminated, and after connecting a test pen to another phase, another LED (L or R) would be illuminated.
  4. L or R LED would be illuminated accordingly when the position of two test pens are exchanged.
  5. LED 將指示相應的音量tage or LCD displays the corresponding voltage 值,指示或顯示的體積tage 應該是相位 voltage against earth but the three-phase voltage.

三相電氣系統測試示意圖(圖4)

筆記: For measuring three-phase AC system, connect three measuring terminals to the corresponding terminal of three-phase system and, since the tester has only two test pen terminals, it is required to form the reference terminal by holding tester handle with finger {through the ground}, therefore it would not accurately indicate the phase sequence of three-phase system if not holding the handle or wearing insulating gloves. In addition, it is necessary to ensure the earth terminal (earth wire or shell) of three-phase system in contact with human body while measuring three-phase power system lower than 1 DOV.UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG (6)

漏電保護測試

減少干擾音量tage期間卷tage measurement, a circuit with impedance lower than the tester under normal measurement mode may be provided between two test pens, namely the RCD circuit system. For RCD trip test, connect two test pens to the Land PE terminal of 230Vac system under normal voltage measurement mode and press RCD key”}” on two test pens, RCD system would trip and the LED indicating RCD(UT1BB/C/E)or RCD symbol {UT1 BD) would be illuminated if the circuit then generates AC current higher than 30mA. Particularly, if RCD cannot measure for a long time and, at 230V, the testing time should be <1 Os, cannot conduct continuous measurement and, after once test, wait 60s before next measurement.

筆記: In case of no measurement or test, it is normal to have a continuously illuminated LED and a continuous beeping buzzer after simultaneously pressing RCD keys on two test pens. To avoid functional disorder, do not press two RCD keys under non-RCD testing mode.

靜音模式選擇

It is allowed to enter the silent mode while tester is under standby mode or normally used. After pressing flashlight key about 1 s, tester would bleep and LCD displays silence symbol “UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG 9” (UT1 BC/D/E), and tester enters silent mode and, under which mode, all functions are similar to those under normal mode, with exception to the silent buzzer. If need to resume normal mode (buzzing mode), press flashlight key about 1 s and, after “bleeps”, the silence symbol “UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG 9”在 LCD 上會消失。

手電筒功能的應用

如果需要在夜間或黑暗環境中使用測試儀,可以選擇手電筒功能; 輕觸測試儀面板上的手電筒按鈕後,頭部amp 測試儀頂部會打開,方便您操作,操作後輕觸按鈕即可關閉燈。

背光應用(僅適用於UT18D)

LCD displayed data may be hard to read at night or n a dark environment, allow the display clearly visible by turning on backlight on tester. Backlight would be turned on after pressing HOLD about 1 s and, after operation, turn off the light after pressing HOLD about 1 s. If tester enters standby mode while backlight is on, the light would remain illuminated when tester is awakened. The backlight cannot be turned off unless pressing HOLD about 1 s again.

HOLD功能的應用(UT18C/D/E)

為便於讀取和記錄,請將測量數據(voltage 和頻率值)在使用測試儀時輕觸測試儀上的 HOLD; 再次輕觸後,保持狀態解除,恢復正常測試狀態。

更換電池

使用 vol 之前tage detector ,Touch and hold the two probe tips together. If UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG 8I shows and you hear the beeper, or in the silent mode, UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG 8I is on. This makes sure that the battery source is not exhausted. otherwise, the battery source is exhausted. Continuously flashing negative LED (UT1BA/B) or low-voltag使用測試儀時 LCD (UT1BC/D/E) 上的 e 符號表示電池電量低tage 和更換電池的必要性。

按照以下步驟更換電池(如圖 5 所示):

  • 停止測量並將兩個測試筆與被測對象斷開;
  • 用螺絲刀擰出固定電池蓋的螺絲;
  • 取下電池蓋;
  • 取出要更換的電池;
  • Install new battery according to the battery symbol and direction indicated on panel; and
  • Insert battery cover and secure it with screwsUNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG (7)

警告:

為避免觸電,在取下後蓋之前,請確保將探頭與被測電路斷開。 使用儀器前,請確保後蓋已擰緊。

筆記: For environmental protection, batteries may be collected and recycled at fixed collection point while disposing the disposable battery or accumulator containing hazardous waste. Please follow the local valid recycling regulations and dispose of the batteries replaced as per disposal rules for old battery and accumulator.

設備維護

No special maintenance requirement is provided unless UT1 BA/B/C/D/E tester should be used as per manual instruction and, in case of any functional abnormality during normal operation, stop using immediately and contact the nearest authorized service center.

設備清洗

清潔前,斷開測試儀與被測電路的連接。 如果儀器在正常使用過程中變髒,請用濕布或少量溫和的家用清潔劑代替酸性清潔劑或溶劑擦拭。 清潔後 5 小時內不要使用測試儀。

技術指標

UNIT-T-UT18A-Voltage-and-Continuity-Tester-FIG 10

防水的 lp65
自動量程 品種齊全
手電筒 品種齊全
低電量音量tag適應症 約2.4V
過卷tag電子保護 約750V  

(1015V only for UT18E)

自動待機 Standby current <1OuA
靜音模式 品種齊全
背光 品種齊全        
液晶顯示(音量tage) 6V~690V     ± (-1 5%+1) ± (-1 5%+1) ±(1.5%+1)

( 100 0 Vo nly

for UT18E)

LCD display (frequency 40Hz~400Hz     ±(3%+5) ±(3%+5) ±(3%+5)

LCD顯示精度指示:

Range (AC/DC) 6V 12V/24V 50V 120V 230V/400V/690V 1000V
UT18C ±(1.5%+1) ±(1.5%+2) ±(1.5%+3) ±(1.5%+4) ±(1.5%+5)  
UT18D ±(1.5%+1) ±(1.5%+2) ±(1.5%+3) ±(1.5%+4) ±(1.5%+5)  
UT18E ±(1.5%+1) ±(1.5%+2) ±(1.5%+3) ±(1.5%+4) ±(1.5%+5) ±(1.5%+5)

範圍

功能及參數說明

  • LED音量tage range: 12V-690V AC/DC, 1000V AC/DC (only for UT1 BE)
  • LED音量tage indication point: 12V, 24V, 50V, 120V, 230V, 400V, 690V, 1000V (only for UT1BE)
  • 液晶顯示卷tage range: 6V-690V AC/DC(UT1 BC/D), 1 000V AC/DC (only for UT1 BE); resolution: 1V, voltage精度:±(1.5%+1-5位);
  • Frequency measurement range: 40Hz-400Hz, resolution: 1 Hz, accuracy: ±(3%+5Digits)
  • 卷tage measurement: Auto
  • 蜂鳴和靜音模式是可選的;
  • 極性指示:自動
  • Range selection: Auto
  • Response time: LED<0.1 s/LCD<1 s
  • Peak current of test circuit: ls<3.5mA (ac/dc)
  • 測試時間:30s
  • 恢復時間:240s
  • RCD test: Range: 230V (50Hz-400Hz); Current: AC30mA~40mA; Test time <1 Os, recovery time: 60s;
  • 過卷tage protection: 750V AC/DC (1015V AC/DC only for UT1BE)
  • On-off test: 0 kΩ … 100kΩ (0KΩ …. 60KΩ only for UT1BE); Accuracy: Rn+50%;
  • 旋轉測試(三相交流)體積tage range: 57V-400V; Frequency range: 50 Hz~60Hz (1 00V-400V only for UT1 BE);
  • 簡單測試(不含電池)體積tage range: 50VAC ~ 690VAC, 120VDC- 690VDC (UT1BA/B/C, 1000Vonly for UT1BE);
  • Working temperature range: -15″C~+45’C
  • Storage temperature range: -2o·c-+60″C
  • Working humidity range: :SB5% RH
  • 過卷tage protection class: CAT Ill 690V,CAT IV 600V,( UT1BE: CAT Ill 1000V,CAT IV 600V)
  • 污染等級:2
  • Safety rules: IP65, EN61010-1, EN61243-3:2010
  • Weight: 23Bg (UT1 BA),272g(UT1 BB/C),295g(UT1 BD) ,277g(UT1 BE) (inclusive of battery);
  • Dimensions: 272xB5x31mm
  • Battery: IEC LR03 (AAA) x 2