Ilogo ye-ACU SCOPE INCWADII-ACCU SCOPE EXI 410 Series Inverted MicroscopeEXI-410
IPHEPHILEYO
UTHENGA LWEMIkroskopu

AMANQAKU OKHUSELEKO

  1. Vula ibhokisi yokuthumela ngocoselelo ukuthintela nasiphi na isincedisi, oko kukuthi iinjongo okanye izibonda zamehlo, ukuba zingawi kwaye zonakaliswe.
  2. Musa ukulahla ibhokisi yeenqanawa ezibunjiweyo; isikhongozeli kufuneka sigcinwe ukuba imakroskopu inokuphinda ifune ukuthunyelwa kwakhona.
  3. Gcina isixhobo ngaphandle kwelanga elithe ngqo, ubushushu obuphezulu okanye ukufuma, kunye neendawo ezinothuli.
    Qinisekisa ukuba imakroskopu ibekwe kwindawo egudileyo, inqanaba kunye nokuqina.
  4. Ukuba naziphi na izisombululo zomzekelo okanye ezinye izinto ezingamanzi zitshiza kwi-stage, injongo okanye naliphi na elinye ilungu, ngoko nangoko qhawula intambo yombane kwaye wosule ukuchitheka. Ngaphandle koko, isixhobo sinokonakala.
  5. Zonke izihlanganisi zombane (intambo yamandla) kufuneka zifakwe kwisicinezeli sombane ukunqanda umonakalo ngenxa yevolthi.tage ukuhla nokuhla.
  6. Kuphephe ukuthintela ukujikeleza komoya wendalo ukupholisa. Qinisekisa ukuba izinto kunye nezithintelo ubuncinane ziisentimitha ezili-10 ukusuka kumacala onke e-microscope (ekuphela kwemeko yitafile ehlala kuyo i-microscope).
  7. Ukhuseleko xa utshintsha i-LED lamp okanye ifuse, qiniseka ukuba isitshixo esikhulu sicinyiwe (“O”), susa intambo yombane, kwaye ubuyisele ibhalbhu ye-LED emva kwebhalbhu kunye ne-lamp indlu ipholile ngokupheleleyo.
  8. Qinisekisa ukuba igalelo voltage eboniswe kwimicroscope yakho ihambelana nomgca wakho wevolumutage. Ukusetyenziswa komthamo wegalelo elahlukileyotage ngaphandle kokuba kubonisiwe kuya kubangela umonakalo omkhulu kwimicroscope.
  9. Xa uphethe le mveliso, bamba ngokuqinileyo imakroskopu ngesandla esinye kwindawo yokuphumla kumbindi ongezantsi womzimba ophambili kunye nesinye isandla kwindawo yokuphumla ngasemva kumzimba ophambili. Jonga kulo mfanekiso ungezantsi.

I-ACCU SCOPE EXI 410 Series Inverted Microscope - AMANQAKU OKHUSELEKO

I-ACCU SCOPE EXI 410 Uthotho lweMicroscope eguqulweyo - Inkwenkwezi Musa ukubamba okanye ubambe usebenzisa nawaphi na amanye amalungu (afana nentsika yokukhanyisa, amaqhina okujolisa, iityhubhu zamehlo okanyetage) xa uphethe imakroskopu. Ukwenza oko kunokubangela ukulahla iyunithi, umonakalo kwi-microscope okanye ukungaphumeleli kokusebenza kakuhle.

INKONZO KUNYE NOLONDOLO

  1. Ungazami ukuqhawula naliphi na ilungu elibandakanya i-eyepieces, iinjongo okanye indibano yokugxila.
  2. Gcina isixhobo sicocekile; susa ubumdaka kunye nobutyobo rhoqo. Ukungcola okuqokelelweyo kwiindawo zetsimbi kufuneka kucocwe ngentengisoamp ilaphu. Ukungcola okuthe gqolo kufuneka kususwe kusetyenziswa isisombululo sesepha ethambileyo. Musa ukusebenzisa i-solvents ye-organic ukucoca.
  3. Umphandle we-optics kufuneka uhlolwe kwaye ucocwe ngamaxesha athile usebenzisa umjelo womoya osuka kwibhalbhu yomoya. Ukuba ubumdaka buhlala kumphezulu obonakalayo, sebenzisa ilaphu elithambileyo okanye iswab yomqhaphu dampenziwe ngesisombululo sokucoca iilensi (efumaneka kwiivenkile zekhamera). Zonke iilensi zamehlo kufuneka zixutywe kusetyenziswa ukunyakaza kwesetyhula. Isilonda esincinci somqhaphu esifunxayo ekupheleni kwentonga ye-tapered efana ne-cotton swabs okanye i-Q-tips, yenza isixhobo esiluncedo sokucoca i-recessed optical surfaces. Kuphephe ukusebenzisa isixa esigqithisileyo sezinyibilikisi njengoko oku kunokubangela iingxaki ngokugqunywa kwamehlo okanye i-optics enesamente okanye isinyibilikisi esiqukuqelayo sinokuchola igrisi sisenza ukucoca kube nzima ngakumbi. Iinjongo zokucwiliswa kwe-oyile kufuneka zicocwe ngoko nangoko emva kokusetyenziswa ngokususa ioli ngethishu yelensi okanye ilaphu elicocekileyo nelithambileyo.
  4. Gcina isixhobo kwindawo epholileyo neyomileyo. Gquma imakroskopu ngesigqubuthelo sothuli xa ungasetyenziswa.
  5. Imicroscopes ye-CCU-SCOPE® zizixhobo ezichanekileyo ezifuna ukugcinwa kothintelo ngamaxesha athile ukuze kugcinwe ukusebenza okufanelekileyo kunye nokubuyekeza ukunxitywa kwesiqhelo. Ishedyuli yonyaka yolondolozo lothintelo ngabasebenzi abaqeqeshiweyo iyacetyiswa kakhulu. Umsasazi wakho ogunyazisiweyo we-ACCU-SCOPE® unokulungiselela le nkonzo.

INTSHAYELELO

Sivuyisana nawe ngokuthenga imakroskopu yakho entsha ye-ACCU-SCOPE®. Iimicroscopes ze-ACCU-SCOPE® zenziwe ngobunjineli kwaye zenziwa ngeyona migangatho iphezulu yomgangatho. I-microscope yakho iya kuhlala ubomi bonke ukuba isetyenziswe kwaye igcinwe kakuhle. Iimicroscopes ze-ACCU-SCOPE® zihlanganiswe ngononophelo, zihlolwe kwaye zivavanywe ngabasebenzi bethu bamagcisa aqeqeshiweyo kwiziko lethu laseNew York. Iinkqubo zokulawula umgangatho ngononophelo ziqinisekisa ukuba i-microscope nganye ikumgangatho ophezulu phambi kokuthunyelwa.

UKUXOXA KUNYE NEZINTO

Imakroskopu yakho ifike ipakishwe kwibhokisi yenqanawa ebunjiweyo. Musa ukulahla ikhathoni: ibhokisi kufuneka igcinwe ukuze ithunyelwe kwakhona ngemakroskopu yakho ukuba iyafuneka. Kuphephe ukubeka imakroskopu kwindawo enothuli okanye kwindawo yobushushu obuphezulu okanye kwindawo ezifumileyo njengoko ukungunda kunye nokungunda kuya kuvela. Susa ngononophelo imakroskopu kwisikhongozeli segwebu se-EPE ngengalo kunye nesiseko kwaye ubeke imakroskopu kwindawo ecaba, engenazo ukungcangcazela. Qwalasela amacandelo kuluhlu olulandelayo lolungelelwaniso olusemgangathweni:

  1. Ukuma, okubandakanya ingalo exhasayo, indlela yokugxininisa, i-nosepiece, i-mechanical stage (ukhetho), i-condenser ene-iris diaphragm, inkqubo yokukhanyisa, kunye nezixhobo zokuchasana kwesigaba (ukhetho).
  2. Ibhinocular viewintloko
  3. Izibonda zamehlo njengoko ziyalelwe
  4. Iinjongo njengoko ziyalelwe
  5. Stagukufakwa kwepleyiti, izihluzi eziluhlaza kunye nezityheli (ukhetho)
  6. Isigqubuthelo sothuli
  7. I-3-prong intambo yamandla ombane
  8. Iiadaptha zekhamera (uyazikhethela)
  9. Iityhubhu zesihluzi seFluorescence (uyazikhethela)

Izincedisi ezizikhethelayo ezifana neenjongo ozikhethelayo kunye/okanye i-eyepieces, iiseti zesilayidi, njl. njl., azithunyelwa njengenxalenye yezixhobo eziqhelekileyo. Ezi zinto, ukuba zi-odolwe, zithunyelwa ngokwahlukeneyo.

AMACANDELO IDIAGRAM

EXI-410 (kunye nePhase Contrast)

I-ACCU SCOPE EXI 410 Series Inverted Microscope - DIAGRAM

1. ISilayidi soMahluko weSigaba
2. Umehlo
3. Eyetube
4. ViewngeNtloko
5. I-Emboss Contrast Slider
6. Isalathisi saMandla
7. Isikhethi sokukhanyisa
8. Isakhelo esingundoqo
9. I-LED Lamp (iyasasazwa)
10. Intsika yokukhanyisa
11. I-Condenser Seta Screw
12. Field Iris Diaphragm
13. Icondenser
14. Injongo
15. Stage
16. Oomatshini Stage kunye Universal Holder (uyazikhethela)
17. Oomatshini StagI-e Control Knobs (XY movement)
18. IKhola yoLungiso lweTension yokuGxininisa
19. Ugqaliselo olungeluhle
20. Ugqaliselo oluhle

EXI-410 (kunye nePhase Contrast) 

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-DIAGRAM 2

1. Intsika yokukhanyisa
2. Field Iris Diaphragm
3. ISilayidi soMahluko weSigaba
4. Icondenser
5. Oomatshini Stage kunye Universal Holder (uyazikhethela)
6. Injongo
7. Umphunga
8. Ukutshintsha Amandla
9. Umehlo
10. Eyetube
11. ViewngeNtloko
12. Isikhethi seNdlela yokuKhanya
13. Isibuko seKhamera
14. Isalathisi saMandla
15. Isikhethi sokukhanyisa
16. I-Illumination Intensity Adjustment Knob

EXI-410 (kunye nePhase Contrast) 

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-DIAGRAM 3

1. ViewngeNtloko
2. Stage
3. I-Emboss Contrast Slider
4. Isakhelo esingundoqo
5. IKhola yoLungiso lweTension yokuGxininisa
6. Ugqaliselo olungeluhle
7. Ugqaliselo oluhle
8. I-Condenser Seta Screw
9. ISilayidi soMahluko weSigaba
10. Icondenser
11. Intsika yokukhanyisa
12. Ukubamba Ngesandla Ngasemva
13. Oomatshini Stage (ukhetho)
14. Umphunga
15. Isisi
16. IsiPhumo saMandla

EXI-410-FL 

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-DIAGRAM 4

1. ISilayidi soMahluko weSigaba
2. Umehlo
3. Eyetube
4. ViewngeNtloko
5. Fluorescence Light Shield
6. I-Emboss Contrast Slider
7. Isalathisi saMandla
8. Isikhethi sokukhanyisa
9. Isakhelo esingundoqo
10. I-LED Lamp (iyasasazwa)
11. Intsika yokukhanyisa
12. I-Condenser Seta Screw
13. Field Iris Diaphragm
14. I-Condenser Centreing Screw
15. Icondenser
16. Ikhaka eliKhanya
17. Injongo
18. Stage
19. Oomatshini Stage kunye Universal Holder (uyazikhethela)
20. I-Fluorescence Illumination
21. Fluorescence Turret
22. Oomatshini StagI-e Control Knobs (XY movement)
23. IKhola yoLungiso lweTension
24. Ugqaliselo olungeluhle
25. Ugqaliselo oluhle

EXI-410-FL 

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-DIAGRAM 5

1. Intsika yokukhanyisa
2. Field Iris Diaphragm
3. ISilayidi soMahluko weSigaba
4. Icondenser
5. Oomatshini Stage kunye Universal Holder (uyazikhethela)
6. Injongo
7. Umphunga
8. Fluorescence Turret
9. Fluorescence Turret Access Door
10. Ukutshintsha Amandla
11. Umehlo
12. Eyetube
13. ViewngeNtloko
14. Isikhethi seNdlela yokuKhanya (Iziqwenga zamehlo/iKhamera)
15. Isibuko seKhamera
16. Isalathisi saMandla
17. Isikhethi sokukhanyisa
18. I-Illumination Intensity Adjustment Knob

EXI-410-FL 

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-DIAGRAM 6

1. ViewngeNtloko
2. Fluorescence Light Shield
3. I-Emboss Contrast Slider
4. Isakhelo esingundoqo
5. IKhola yoLungiso lweTension yokuGxininisa
6. Ugqaliselo olungeluhle
7. Ugqaliselo oluhle
8. I-Condenser Seta Screw
9. ISilayidi soMahluko weSigaba
10. Icondenser
11. Intsika yokukhanyisa
12. Ikhaka eliKhanya
13. Ukubamba Ngesandla Ngasemva
14. Oomatshini Stage (ukhetho)
15. Umphunga
16. Umthombo wokukhanya we-LED Fluorescence
17. Isisi
18. IsiPhumo saMandla

IMILINGANISELO YEMIkroskopu

EXI-410 Phase Contrast kunye Brightfield

I-ACCU SCOPE EXI 410 Series Inverted Microscope - Brightfield

EXI-410-FL kunye noMechanical Stage

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-Mechanical Stage

IDAYAGRAM YENDIBANO

Lo mzobo ungezantsi ubonisa indlela yokudibanisa amacandelo ahlukeneyo. Amanani abonisa ulandelelwano lwendibano. Sebenzisa i-hex wrenches ebonelelwa ngemicroscope yakho xa kufuneka. Qinisekisa ukugcina ezi wrenches zokutshintsha amacandelo okanye ukwenza uhlengahlengiso.
Xa udibanisa imakroskopu, qiniseka ukuba zonke iindawo azinalo uthuli nokungcola, kwaye ugweme ukukrwela ukukrwela naziphi na iindawo okanye ukubamba imiphezulu yeglasi.

I-ACCU SCOPE EXI 410 Series Inverted Microscope - INDIBANO

INDIBANO

Icondenser
Ukufakela i-condenser:

  1. Khulula isikrufu seseti yecondenser ngokwaneleyo ukuvumela ityhubhu yecondenser ukuba islayidise phezu komqolo we-dovetail yehanger yecondenser.
  2. Cinezela kancinci i-condenser kwindawo kwaye uqinise isikrufu sokusetha.

I-ACCU SCOPE EXI 410 Series Inverted Microscope-Condenser

ISilayidi soMahluko weSigaba
Ukufakela isilayida sesigaba sokuchasana:

  1. Ngemibhalo eshicilelweyo kwisilayidi ejonge phezulu kwaye ifundeka ngaphambili kwimakroskopu, faka isilayida sesigaba sokuchasana ngokuthe tye kwi-condenser slot. I-orientation ye-slider ichanekile ukuba umgca wesilayidi esijongene nomsebenzisi unezikrufu zokulungelelanisa ezibonakalayo.
  2. Qhubeka ufaka isilayidi kude kube "cofa" okuvakalayo kubonisa ukuba indawo enye ye-3-postion phase umehluko slider ihambelana ne-optical axis. Faka isilayida ngakumbi kwi-slot okanye ngasemva ukuya kwindawo efunekayo yesilayidi.

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo - Isilayidi sokuchasana

Umatshini Stage (ukhetho)
Ukufakela umatshini ozikhethelayo stage:

  1. Faka oomatshini ngokwendlela ① (njengoko kubonisiwe kumfanekiso). Okokuqala, lungelelanisa umgca we-A we-mechanical stage ngomphetho weflethi / ithafa stagumphezulu. Lungelelanisa oomatshini stage kunye ithafa stage de izikrufu ezimbini iseti ezantsi koomatshini staglungelelanisa imingxuma yezikrufu kumazantsi ethafa stage. Qinisa izikrufu ezimbini.
  2. Faka isibambi sendalo yonke ngokwendlela ② (njengoko kubonisiwe kumfanekiso). Qala ngokubeka ipleyiti yesibambi esisicaba kwi-plain stagumphezulu. Lungelelanisa imingxuma emibini yezikrufu kwipleyiti yesibambi sehlabathi kunye nezikrufu ezimiselweyo kwirula yentshukumo esecaleni yesixhobo somatshini.tage. Qinisa izikrufu ezimbini.

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-Mechanical Stage 2

Iinjongo
Ukufakela iinjongo:

  1. Jika iknobhu yohlengahlengiso erhabaxa ① de intambo yempumlo ejikelezayo ibe kweyona ndawo iphantsi.
  2. Susa umnqwazi wempumlo ② ekufutshane nawe kwaye uthunge eyona njongo yokukhulisa isezantsi kwindawo yokuvula impumlo, emva koko ujikelezise intambo yempumlo ngokwewotshi kwaye uthunge ezinye iinjongo ukusuka ezantsi ukuya phezulu.

I-ACCU SCOPE EXI 410 Series Inverted Microscope - Iinjongo

PHAWULA:

  • Soloko ujikelezisa intambo yempumlo ngokusebenzisa iknurled umsesane wempumlo.
  • Gcina izigqumathelo kuzo naziphi na iindawo ezivulekileyo zempumlo ezingasetyenziswanga ukuthintela uthuli kunye nobumdaka ukuba bungene ngaphakathi.

Stage Icwecwe
Faka iglasi ecacileyo stagipleyiti ① kwindawo yokuvula kwi-stage. Iglasi ecocekileyo ikuvumela ukuba wenze view injongo kwisikhundla.

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo - Stage Icwecwe

Imizobo yamehlo
Susa iiplagi ze-eyetube kwaye ufake ngokupheleleyo imihombiso yamehlo ① kwityhubhu ye-eyepiece ②.

I-ACCU SCOPE EXI 410 Series Inverted Microscope-Eyepieces

Ikhamera (ukhetho)
Ukufakela ikhamera oyikhethayo:

  1. Susa isigqubuthelo sothuli kwilensi ye-1X yokudlulisela.
  2. Gcoba ikhamera kwilensi yokudlulisa njengoko kubonisiwe.
    PHAWULA:
    ● Soloko ugcina isandla esinye kwikhamera ukuyithintela ukuba ingawi.I-ACCU SCOPE EXI 410 Uthotho lweMicroscope eguqulweyo - Ikhamera
  3. Ukwandiswa kwelensi yekhamera ezininzi kuyafumaneka ngokuxhomekeke kwisicelo kunye/okanye ubungakanani boluvo lwekhamera.
    a. I-lens ye-1X isemgangathweni kwaye ifakwe kunye ne-microscope. Olu lwandiso lufanelekile kwiikhamera ezinobungakanani be-sensor diagonal ye-2/3" kunye nenkulu.
    b. I-lens ye-0.7X (ukhetho) iya kuthatha i-sensors yekhamera ye-½ "ukuya ku-2/3". Izinzwa ezinkulu zinokukhokelela kwimifanekiso ene-vignetting ebalulekileyo.
    c. Ilensi engu-0.5X (ukhetho) ithatha i-½” yoluvo lwekhamera kunye nezincinci. Izinzwa ezinkulu zinokukhokelela kwimifanekiso ene-vignetting ebalulekileyo.

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-Ikhamera 2

Fluorescence Filter Cubes
(imizekelo ye-EXI-410-FL kuphela)
FUNDA IPHEPHA 17-18 UKUZE NGENE NGINGQO
Ukufakela iityhubhu yesihluzo se-fluorescence:

  1. Susa isigqubuthelo kwizibuko lokufakela iityhubhu kwicala lasekhohlo lemakroskopu.
  2. Jikelezisa i-turret yokucoca kwindawo eyamkela iityhubhu zesihluzi.
  3. Ukuba ubuyisela ityhubhu yokucoca esele ikhona, susa elo tyhubhu yesihluzo kuqala kwindawo ekuza kubekwa kuyo iityhubhu entsha yokucoca. Lungelelanisa ityhubhu yesihluzo kunye nesikhokelo kunye nomsele phambi kokufaka. Faka ngokupheleleyo de kuviwe "cofa" okuvakalayo.
  4. Buyisela isigqubuthelo se-turret yokucoca.

I-ACCU SCOPE EXI 410 Uthotho lweMicroscope eguqulweyo-Iiityhubhu zesihluzi

PHAWULA:

  • Iiseti zokucoca i-Fluorescence kufuneka zihambelane nomthombo wokukhanya we-LED we-fluorescence kunye ne-fluorescence probes ezisetyenziswa kwisicelo. Nceda uqhagamshelane ne-ACCU-SCOPE ngayo nayiphi na imibuzo emalunga nokuhambelana.

Ukufakela i-Fluorescence Filter Cubes 

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-Iityhubhu zesihluzi 2

Kuhlohlwa iiCube zesihluzi seFluorescence\

  1. Ukufakela ityhubhu yokucoca, lungelelanisa inotshi yetyhubhu kunye nephini yokhuselo ngaphakathi ekunene kwesixhobo se-turret kwaye uslayide ngononophelo ityhubhu ngaphakathi ide icofe endaweni.I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-Iityhubhu zesihluzi 1
  2. Iboniswe apha, ityhubhu yesihluzi ihleli ngokufanelekileyo kwaye ifakiwe.I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-Iityhubhu zesihluzi 3

PHAWULA

  • Ungaze uchukumise nayiphi na indawo yesihluzi setyhubhu ngaphandle kwebhokisi emnyama.
  • Qinisekisa ukuba ubuyisela ngononophelo ikhava ye-turret ukunqanda ukuphuka.

Ikhodi yamandla
UMQULUTAGQAPHELA
Qinisekisa ukuba igalelo voltage eboniswe kwileyibhile engasemva yemakroskopu ihambelana nomthamo wakho womgcatage. Ukusetyenziswa komthamo wegalelo elahlukileyotage kunokuba kubonisiwe kuya kubangela umonakalo omkhulu kwimicroscope yakho.
Ukuqhagamshela iNtambo yaMandla
Qinisekisa ukuba i-On/Off Switch ngu-“O” (indawo yokucima) phambi kokudibanisa intambo yombane. Faka iplagi yamandla kwisixhobo sombane semakroskopu; qinisekisa ukuba unxibelelwano luqinile. Qhagamshela intambo yombane kwisixhobo sokubonelela ngombane.
PHAWULA: Soloko usebenzisa intambo yamandla eze nemicroscope yakho. Ukuba intambo yakho yombane yonakele okanye ilahleke, nceda ufowunele umthengisi ogunyazisiweyo we-ACCU-SCOPE ukuze uyitshintshe.

UKUSEBENZA

Ukuvula amandla
Xhuma intambo yomgca we-3-prong kwi-outlet yamandla ye-microscope kwaye emva koko kwi-120V okanye i-220V yombane ye-AC esekelwe phantsi. Ukusetyenziswa kwe-surgeon suppressor outlet kucetyiswa kakhulu. Vula iswitshi yesikhanyisi ① ukuya “―”, emva koko ucinezele isikhethi sokhanyiso ② ukuguqula isibane sikhanyise (isalathisi samandla ③ siya kukhanya). Ixesha elide lamp ubomi, soloko ujika iknobhu yokuqina kwesikhanyisi ④ ukuya kwelona lungiselelo lokhanyiso lisezantsi linokwenzeka phambi kokuba uvule okanye ucime umbane.

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-Ukunika amandla

Ukulungelelanisa ukuKhanya
Umgangatho wokukhanya unokufuna uhlengahlengiso ngokuxhomekeke kuxinaniso lwesampulu kunye nokwandiswa kwenjongo. Lungisa ubunzulu bokukhanya ukuze ukhululeke viewngokujika iqhoshana lokulawula ubunzulu bokukhanya ④ ngasekunene (ukubhekisa kumqhubi) ukwandisa ukukhanya. Jika ngokuchasene newotshi (usuke kumsebenzisi) ukunciphisa ukukhanya.

I-ACCU SCOPE EXI 410 Series Inverted Microscope-Illumination

Ukulungelelanisa umgama we-Interpupillary
Ukulungelelanisa umgama we-interpupillary, bamba i-eyetubes yasekhohlo nasekunene ngelixa uqwalasela umboniso. Jikelezisa i-eyetubes ujikeleze i-axis esembindini kude kube ngamasimi e view omabini amathubhu adibana ngokupheleleyo. Isangqa esipheleleyo kufuneka sibonakale kwi viewintsimi xa viewngokwenza isilayidi somzekelo. Uhlengahlengiso olungafanelekanga luya kubangela ukudinwa kwabaqhubi kwaye kuya kuphazamisa i-parfocality yenjongo.
Apho i-“●” ① kwityhubhu yamehlo ijonge phezulu, leyo linani lomgama wakho we-interpupillary. Uluhlu luyi-5475mm. Qaphela inombolo yakho ye-interpupillary ukuze usebenze kwixesha elizayo.

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-Interpupillary Distance

Ukulungelelanisa Ugxininiso
Ukuqinisekisa ukuba ufumana imifanekiso ebukhali ngawo omabini amehlo, (ekubeni amehlo engafani, ngakumbi kwabo banxibe iindondo) nakuphi na ukwahluka kwamehlo kunokulungiswa ngolu hlobo lulandelayo. Seta zombini iikhola zediopter ② ukuya ku-"0". Usebenzisa iliso lakho lasekhohlo kuphela kunye nenjongo ye-10X, gxila kumzekelo wakho ngokuhlengahlengisa iknobhu yohlengahlengiso olurhabaxa. Xa umfanekiso ungaphakathi view, cokisa umfanekiso ukuya kugxininiso lwawo olubukhali ngokujika iqhosha lokulungisa elilungileyo. Jikelezisa ikhola yediopter ukufumana eyona nto ibukhali. Ukufumana umfanekiso obukhali ofanayo usebenzisa iliso lakho lasekunene, ungachukumisi uhlengahlengiso olurhabaxa okanye olucolekileyo. Endaweni yoko, jikelisa ikhola ye-diopter elungileyo de kuvele umfanekiso obukhali. Phinda amaxesha amaninzi ukujonga.
OKUBALULEKILEYO: musa ukuphikisa ukujikelezisa amaqhina ogxininiso njengoko oku kuya kubangela iingxaki ezinzima kunye nomonakalo kwinkqubo yokugxila.

I-ACCU SCOPE EXI 410 Uthotho lweMicroscope eguquliweyo - Gxininisa

Ukugxininisa kuMfanekiso
Ukulungelelanisa ugxininiso, jikelezisa amaqhosha okugxila kwicala lasekunene okanye lasekhohlo le-microscope ukuhambisa injongo phezulu nasezantsi. Ugqaliselo olurhabaxa ① kunye nogqaliselo oluhle ② amaqhina achongwa kumzobo osekunene.
Umzobo ongasekunene ubonisa unxulumano phakathi komkhombandlela ojikelezayo wamaqhina ekugxilwe kuwo kunye nokushukuma okuthe nkqo kwenjongo.
Gxininisa kuhambo: Ukuhamba kugxininiso olungagqibekanga ukusuka kumphezulu wethafa stage phezulu 7mm kwaye phantsi 1.5mm. Umda unokunyuswa ukuya kuthi ga kwi-18.5mm ngokulungelelanisa isikrufu somda.

I-ACCU SCOPE EXI 410 Series Inverted Microscope-Special

Ukulungelelanisa Uxinzelelo Olugxininiso
Ukuba ukuziva kunzima kakhulu xa kugxilwe ngamaqhina okugxila ②③, okanye umzekelo ushiya inqwelomoya ekugxilwe kuyo emva kokugxila, okanye i-stagI-e ithoba ngokwayo, lungelelanisa uxinzelelo kunye neringi yohlengahlengiso loxinzelelo ①. Iringi yetension yeyona iringi yangaphakathi enamaqhina okujolisa.
Jika iringi yohlengahlengiso lwewotshi ukukhulula okanye ikhawuntasi ukuze uqinise ngokokhetho lomsebenzisi.

I-ACCU SCOPE EXI 410 Series Inverted Microscope-Ukugxilwa kweTension

Ukusebenzisa i-Stage Amacwecwe (Ngokuzikhethela)
PHAWULA: ngokugqibeleleyo viewukuba, qinisekisa ubukhulu besikhongozeli, isitya okanye isilayidi sihambelana nobukhulu obuphawulwe kwinjongo nganye (0.17mm okanye 1.2mm). Ngeenjongo zanamhlanje, i-coverglass iphezulu kakhulu i-0.17mm ubukhulu (No. 1½), ngelixa iinqanawa ezininzi zenkcubeko ye-tissue ziyi-1-1.2mm. Ukungahambelani phakathi kobukhulu besilayidi/ubukhulu besitya kunye noko bekuyilelwe injongo kunokubonisa umfanekiso ongaphandle kokugxila.

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo - Stage Amacwecwe

Ngomatshini stage ①, umsebenzisi unokusebenzisa naziphi na iinketho ezikhethiweyotagiipleyiti zeeflaski, iipleyiti zequla, izitya zenkcubeko okanye izilayidi. Umzobo osekunene ubonisa indibaniselwano 60mm Petri dish/microscope isibambi sesilayidi ② exhonywe kwisibambi sendalo yonke somatshinitage. Isibambi somzekelo singasuswa ngokujika i X③ kunye ne Y④ stagulawulo lwentshukumo.
Ukukhetha iNdlela yoKhanya
I-EXI-410 ifakwe i-binocular viewIntloko enekhamera enye yomfanekiso wedijithali. Kuya kufuneka ukhethe indlela yokukhanya efanelekileyo yokujonga kunye nemifanekiso yemifanekiso.
Xa isilayida sokukhetha indlela yokukhanya ① imiselwe kwindawo ethi "IN" (ityhale yonke indlela ukuya kwi-microscope), indlela yokukhanya ithumela i-100% yokukhanya kwi-eyepieces ye-binocular.
Xa i-slider yokukhetha indlela yokukhanya ikwindawo ethi "OUT" (itsalwe yonke indlela ukuya kwesobunxele, kude ne-microscope), i-20% yokukhanya ithunyelwa kwi-binocular eyepieces kwaye i-80% yokukhanya iqondiswe kwikhamera. izibuko lokujongwa kunye nemifanekiso ngekhamera yedijithali.
Kwiiyunithi zefluorescence, indlela yokukhanya ilungiselelwe nokuba yi-100% ukuya kwibhayinotyhula. viewintloko (“IN” indawo), okanye 100% kwizibuko lekhamera (“OUT” indawo).

I-ACCU SCOPE EXI 410 Series Inverted Mikroskopu - Indlela yokukhanya

Ukusebenzisa i-Aperture Diaphragm
I-iris diaphragm imisela ukuvuleka kwamanani (NA) kwenkqubo yokukhanyisa ekubonweni kwentsimi eqaqambileyo.
Xa i-NA yenjongo kunye nenkqubo yokukhanyisa ihambelana, ufumana ibhalansi efanelekileyo yesisombululo somfanekiso kunye nokuchasana, kunye nokunyuka kobunzulu bokugxila.
Ukujonga i-iris diaphragm: susa i-eyepiece kwaye ufake i-telescope ephakathi (ukuba uthenge enye).
Xa ujonga ngeso, uya kubona intsimi ye view njengoko kubonisiwe kumzobo osekunene. Lungisa i-iris diaphragm lever kumlinganiselo owufunayo.
Xa uqwalasela isampuli edayiweyo, seta iris diaphragm ② ukuya kwi-70-80% ye-NA yenjongo ① esetyenziswayo. Nangona kunjalo, xa uqwalasela umzekelo wenkcubeko ephilayo engadaywanga (engenambala phantse), seta iris diaphragm ukuya kwi-75% ye-NA yenjongo esetyenziswayo.

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-I-Aperture Diaphragm

PHAWULA: I-diaphragm ye-iris evaliweyo kakhulu iya kunika i-artifacts ebonakalayo emfanekisweni. I-iris diaphragm evuleke kakhulu inokwenza umfanekiso ubonakale “uhlanjiwe”.
Uqwalaselo lokuchasana kweSigaba
Ngokuxhomekeke kuqwalaselo olucwangcisiweyo, i-EXI-410 ingasetyenziselwa ukujonga ukuchasana kwesigaba kunye neenjongo zokuthelekisa isigaba se-LWD: 4x, 10x, 20x kunye ne-40x.
Ukujonga ukuchasana kwesigaba, buyisela iinjongo eziqhelekileyo kunye neenjongo zokungafani kwesigaba kwi-nosepiece - bhekisa kwiphepha lesi-8 ngemiyalelo yokufakela injongo. Ukuqwalaselwa kweBrightfield kusenokwenziwa ngeenjongo zokuchasana kwesigaba, kodwa ukuqwalaselwa kwesigaba sokuchasana kufuna iinjongo zokuchasana kwesigaba.
ISilayidi soMahluko weSigaba
Isilayidi sesigaba esilungelelanisiweyo silungelelaniswe kwangaphambili kwindawo yethu, ngoko ke uhlengahlengiso olongezelelweyo aluyomfuneko. Ukuba i-ring phase ayigxininisi, ungayilungisa ngokubeka i-bolt kunye ne-2mm hex wrench enikezelwe nge-microscope - jonga imiyalelo engezantsi.
I-EXI-410-PH ibandakanya isilayidi sesigaba se-3.
Isikhundla soku-1 senjongo ye-4x; Isikhundla se-2 seyenjongo ye-10x/20x/40x. Indawo yesi-3 “ivuliwe” ukuze isetyenziswe nezihluzo ozikhethelayo.
Tshatisa i-4x kunye ne-10x/20x/40x i-annuli yokukhanya kunye neenjongo zokuchasana kwesigaba sokuthelekisa ukukhuliswa.

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-Uthelekiso lwesilayida 2

Ukuhlohla iSilayidi seNqanaba (Ngokuzikhethela) (Jonga iPhepha le-14)
Ukumisa i-Annulus yokukhanya
Isilayidi sesigaba silungelelaniswe kwangaphambili kumaziko ethu. Ukuba uhlengahlengiso luyimfuneko, landela la manyathelo:

  1. Beka umzekelo kwi-stage kwaye uyifake kwingqwalasela.
  2. Buyisela i-eyepiece kwityhubhu yamehlo kunye neteleskopu ephakathi (ukhetho).
  3. Qinisekisa ukuba ukwandiswa kwenjongo kwindlela yokukhanya ihambelana ne-annulus yokukhanya kwisilayidi sesigaba.
  4. Ngelixa ujonga ngeteleskopu ephakathi, hlengahlengisa ukugxila kwayo kwisigaba sonyaka ② senjongo kunye nokukhanya okuhambelanayo kwe-annulus ①. Jonga umfanekiso okwiphepha elidlulileyo.I-ACCU SCOPE EXI 410 Series Inverted Microscope - Light Annulus
  5. Faka i-2mm hex wrench kwimingxuma emibini esembindini yesikrufu kwisilayida sesigaba ③. Qinisa kwaye ukhulule izikrufu zeziko de kube i-annulus yokukhanya ibekwe phezulu kwi-annulus yesigaba senjongo.I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-Ukukhanya kweAnnulus 2
  6. Phinda amanyathelo angentla ukulungelelanisa i-centering kunye nezinye iinjongo kunye ne-annuli yokukhanya ehambelanayo.

AMANQAKU:

  • Imifanekiso yesiporho efana ne-Halo ye-annulus yokukhanya inokuvela ngamanye amaxesha. Oku kuyenzeka, phakamisa owona mfanekiso uqaqambileyo we-annulus ngaphezulu kwesigaba se-annulus.
  • Xa umfuziselo ongqindilili ushukunyiswa okanye utshintshwa, i-annulus yokukhanya kunye ne-phase annulus zinokuphambuka. Oku kuqhelekile ngenxa yesixa semidiya okanye ukungangqinelani kwe-wellplate ethile. Oku kunokunciphisa umahluko womfanekiso. Ukuba oku kuyenzeka, phinda amanyathelo 1-5 ukulungisa kwakhona.
  • Inkqubo yogcino kusenokufuneka iphindwe ukuze kufumaneke owona mahluko ungcono ukuba isilayidi somzekelo okanye umphezulu osezantsi wenqanawa yenkcubeko awusicaba. Beka i-annulus yokukhanya usebenzisa iinjongo ngokulandelelana kokwandisa okuphantsi ukuya phezulu.

I-ACCU SCOPE EXI 410 Series Inverted Microscope - umfanekiso wesiporho

I-Emboss Contrast Ebservation
I-emboss yokuchasanisa imakroskopu ifuna isilayida sochasaniso se-condenser-side emboss kunye ne-eyepiecetube-side emboss isilayida sokuchasanisa. Ezi zithunyelwe nge-microscope kunye nemiyalelo yofakelo kunye nokusebenza ingezantsi.
I-Condenser-side Emboss Contrast Slider
I-condenser-side emboss isilayidi sokuchasana sixhotyiswe ngediaphragm yecandelo. Ukuncamathisela isibonakude esisembindini kwityhubhu yamehlo kwenza ukuba ukwazi view umfanekiso wediaphragm yecandelo.
Ungatshintsha isalathiso somchako womfanekiso ngokujikelezisa i-condenser-side emboss isilungelelanisi sesilayidi sokuchasa ukuguqula idiaphragm yecandelo.
Ukusebenzisa isilayida sokuchasana se-condenser-side emboss, qala ngokususa isilayida sesigaba sokuchasa kwi-condenser.
Emva koko faka i-condenser-side emboss isilayida sokuchasanisa kwisilayidi se-condenser slot ①.

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-Uthelekiso lwesilayida 3

I-Eyetube-side Emboss Contrast Slider
I-eyepiece-tube-side emboss opposite slider ineempawu ezininzi zendawo ezihambelana nokukhulisa injongo, kunye neendawo ezininzi zokumisa ukuqinisekisa ukulungelelaniswa kweendawo zokuvula kunye nendlela yokukhanya. Kwi-emboss umahluko wemicroscope, faka isilayidi kwi-microscope de ifike kwindawo enani elifanayo njengokukhulisa injongo. Ukutshintshela umva kwi-brightfield microscopy, khupha isilayidi kwindawo engenanto. Indawo yesilayidi ❶ ihambelana nokuvula ①, ❷ ngo-②, njalo njalo.
Ukuze uqwalaselwe ngaphandle kochasaniso lwe-emboss, qinisekisa ukuba isilayida sokuchasana se-condenser-side emboss sikwindawo evulekileyo, kwaye i-eyetube-side slider ikwindawo ❶.

I-ACCU SCOPE EXI 410 Uthotho lweMikroskopu eGuquliweyo-Uthelekiso lwe-Emboss

Ukusebenzisa ikhamera yeMicroscopy (Ngokuzikhethela)
Ukufakela abantu abathandanayo (Jonga iPhepha le-16)
Ukukhetha iNdlela yoKhanya yokuJonga/ukwenza umfanekiso ngeKhamera (Jonga iPhepha lama-21)
Ukusebenzisa iFluorescence (EXI-410-FL kuphela)
Ukuba uthenge i-EXI-410 yakho nge-fluorescence, inkqubo yakho ye-fluorescence epheleleyo ifakwe kwangaphambili, ilungelelaniswe kwaye ivavanywe ngamagcisa ethu aqeqeshiweyo kwiinkcukacha zakho ngaphambi kokuthunyelwa.
Indlela yokukhanya yokukhanya kwe-fluorescence ibandakanya:

  • Iimodyuli ezidityanisiweyo zokukhanyisa ze-LED fluorescence
  • Isilayida se-Dovetail filter
  • I-3 isikhundla se-fluorescence filter turret.

Indawo nganye yesihluzo se-turret ibonisa unqakrazo olulungileyo lokumisa ibhola-isikhundla esinebhola kunye neempawu eziprintiweyo ngaphezulu kwe-kn.urled ivili elichonga indawo ye-turret kwindlela yokukhanya.
Jonga kumaphepha 8-10 kwiidayagram zecandelo le-EXI-410-FL.
I-EXI-410-FL ayifumaneki ngeminye imithombo yokukhanya ye-fluorescence.
Iiseti ezahlukeneyo zokucoca zikwakhona ukuze kufakwe. Ukukhethwa kweeseti zokucoca kuxhomekeke kwiimodyuli ze-LED ze-fluorescence ezikhoyo kwi-microscope yakho. Qhagamshelana nomthengisi wakho ogunyazisiweyo we-ACCU-SCOPE, okanye usitsalele umnxeba kule nombolo 631864-1000 ukuze ufumane uluhlu lweeseti zokucoca ezifumanekayo nezicetyiswayo.
I-Fluorescence esebenzayo (EXI-410-FL kuphela)
Ukukhanya kwe-Epi-fluorescence
Njengoko kubonisiwe umfanekiso osekunene, cofa iqhosha lesikhethi sokukhanyisa ukuze utshintshe phakathi kwe-epi-fluorescence yokukhanyisa kunye neendlela zokukhanyisa.
Ubukhulu bokukhanya kwe-fluorescence LED buya kwanda xa ujikeleza ulwalathiso lwe-llumination intensity adjustment knob njengakwimzobo osekunene, ngokufanayo naxa usebenzisa isikhanyiso se-LED esithunyelwayo.
PHAWULA: Ukunciphisa i-photobleaching ye-specimen kwaye ugweme "i-autofluorescence" ukusuka kwimodyuli yokukhanya ye-LED edlulisiweyo, qinisekisa ukuba isikhuselo sokukhanya sijikelezwe kwindawo yaso ephantsi (njengoko kubonisiwe kumfanekiso ngakwesokudla.

I-ACCU SCOPE EXI 410 Uthotho lweMicroscope eguqulweyo-I-Fluorescence esebenzayo

Fluorescence Cube Turret
I-fluorescence cube turret iqondisa ukukhanya kokukhanya kwe-excitation ukusuka kwiyunithi ye-fluorescence ye-LED ibe yinjongo. I-turret yamkela ukuya kuthi ga kwiityhubhu zokucoca ezintathu.
Guqula icebo lokucoca kwindlela yokukhanya ngokujikelezisa isihluzo ityhubhu turret. Xa iityhubhu yokucoca itshintshiwe, iyunithi ye-fluorescence ye-LED nayo iyazitshintshela.

I-ACCU SCOPE EXI 410 Uthotho lweMicroscope eguqulweyo-Cube Turret 1

Izikhundla zeBrightfield kwi-turret ziboniswa ngu I-ACCU SCOPE EXI 410 Uthotho lweMicroscope eguqulweyo - ICON Isimboli kunye nokutshintshisana ngeendawo ezintathu zokucoca i-fluorescence tyhubhu. I-Detents kwi-turret ibonisa xa i-cube yokucoca okanye indawo ekhanyayo ibandakanyeka. Indawo yokucoca i-turret ibonakala kumda wevili le-turret ukusuka kumacala omabini asekhohlo nasekunene kwi-microscope. Xa utshintshela ityhubhu yokucoca, khangela ukuba i-turret iyacofa kwityhubhu efunekayo yokucoca okanye indawo eqaqambileyo.

I-ACCU SCOPE EXI 410 Uthotho lweMicroscope eguqulweyo-Cube Turret 2

PHAWULA: Isibane sokukhanya kwe-UV sibandakanyiwe kunye nenguqulo ye-EXI-410-FL ukunciphisa ukukhanya okungaphandle kwi-fluorescence s.ample.

I-ACCU SCOPE EXI 410 Uthotho lweMicroscope eguqulweyo-Cube Turret 3

UKULUNGISA INGXAKI

Phantsi kweemeko ezithile, ukusebenza kwale yunithi kunokuchaphazeleka kakubi ngezinye izinto ngaphandle kweziphene. Ukuba kukho ingxaki, nceda uphindeview olu luhlu lulandelayo kwaye uthathe amanyathelo okulungisa njengoko kufuneka. Ukuba awukwazi ukusombulula ingxaki emva kokujonga uluhlu luphela, nceda uqhagamshelane nomthengisi wakho wendawo ukuze ufumane uncedo.
IMIBONO 

INGXAKI UMBANGELA ISISOMBULULO
Ukukhanya kuvuliwe, kodwa intsimi ye view kumnyama. Ibhalbhu ye-LED itshile yaphela. Ukukhanya kubekwe phantsi kakhulu.
Izihluzo ezininzi kakhulu zipakishwe.
Yifake entsha.
Yibeke kwindawo efanelekileyo.
Zinciphise zibe kwelona nani lifunekayo.
Umda wentsimi ye view lisithekile okanye alikhanyiswanga ngokulinganayo. I-nosepiece ayikho kwindawo ekhoyo.
Isihluzo sombala asifakwanga ngokupheleleyo.
Isilayida sesigaba sokuchasana asibekwa kwindawo efanelekileyo.
Jika intambo yempumlo ibe kwindawo apho unokuva ukuba ibandakanyeka.
Yityhale ngayo yonke indlela.
Shenxisa isilayida de sicofe endaweni.
Ukungcola okanye uthuli lubonakala kwintsimi ye view.
- Okanye -
Umfanekiso unokukhanya.
Ukungcola / uthuli kwisampulu.
Ukungcola / uthuli kwi-eyepiece.
I-iris diaphragm ivalwe kakhulu.
Coca okanye ubuyisele umfuziselo.
Coca izibonda zamehlo.
Vula i-iris diaphragm ngakumbi.
Injongo ayibandakanyekanga ngokuchanekileyo kwindlela yokukhanya. Guqula i-nosepiece kwindawo edibeneyo.
Ukubonakala kumbi
• Umfanekiso awubukhali
• Umahluko umbi
• Iinkcukacha azicacanga
I-diaphragm yokuvula iyavulwa okanye imiswe kude kakhulu ekuqwalaselweni kwendawo eqaqambileyo.
Ilens (condenser, objective, ocular, or culture dish) ibamdaka.
Kwinqanaba lokuqwalaselwa kwesigaba, ubukhulu obuphantsi besitya senkcubeko bungaphezulu kwe-1.2mm.
Ukusebenzisa injongo eqaqambileyo.
I-annulus yokukhanya ye-condenser ayihambelani nesigaba se-annulus yenjongo.
I-annulus yokukhanya kunye ne-phase annulus ayigxilwanga.
Injongo esetyenzisiweyo ayihambelani
ngokuqwalaselwa kwesigaba sokuchasana.
Xa ujonga umda wesitya senkcubeko, i-ring yesigaba sokuchasana kunye nendandatho yokukhanya iyaphambuka omnye komnye.
Lungisa i-diaphragm yokuvula ngokufanelekileyo.
Yicoce kakuhle.
Sebenzisa isitya senkcubeko esinobunzima obusezantsi obungaphantsi kwe-1.2mm, okanye usebenzise injongo yomgama omde wokusebenza.
Tshintshela kwinjongo yokuchasana kwesigaba.
Lungisa i-annulus yokukhanya ukwenzela ukuba ihambelane nesigaba se-annulus yeenjongo
Lungisa izikrufu ezisembindini ukuze zibe sembindini.
Nceda usebenzise injongo ehambelanayo.
Hambisa isitya senkcubeko ude ufumane isiphumo sokuchasana kwesigaba. Unga
kwakhona susa isilayida sesigaba sokuchasana, kwaye usete i-lever ye-diaphragm yasendle ukuba “I-ACCU SCOPE EXI 410 Uthotho lweMicroscope eGuquliweyo-ICON 2
Isiphumo sokuchasana kwesigaba asifumaneki. Injongo ayikho embindini wendlela yokukhanya.
Lo mzekelo awuxhonywanga ngokuchanekileyo kwi-stage.
Ukusebenza kokubona kweplate esezantsi yenqanawa yenkcubeko kubi (profile
isitenxo, njl. njl.).
Qinisekisa ukuba i-nosepiece ikwindawo "ecofayo".
Beka umzekelo kwi-stage ngokuchanekileyo.
Sebenzisa inqanawa enepro elungileyofile uphawu lokutenxa.

ICANDELO LOOMATSHINI

INGXAKI  UMBANGELA  ISISOMBULULO
Iqhina lohlengahlengiso elirhabaxa linzima kakhulu ukulijikeleza. Iringi yohlengahlengiso loxinzelelo iqiniswe kakhulu. Yikhulule ngokufanelekileyo.
Umfanekiso uphuma kwingqwalasela ngexesha lokuqwalaselwa. Ikhola yohlengahlengiso loxinzelelo ikhululekile kakhulu. Yiqinise ngokufanelekileyo.

INKQUBO YOMbane

INGXAKI  UMBANGELA  ISISOMBULULO
I lamp ayikhanyisi Akukho mandla kwi-lamp Jonga intambo yamandla idityaniswe ngokuchanekileyo
QAPHELA: Lamp Ukutshintshwa
Isibane se-LED siya kubonelela malunga neeyure ezingama-20,000 zokukhanya phantsi kokusetyenziswa okuqhelekileyo. Ukuba kufuneka utshintshe ibhalbhu ye-LED, nceda uqhagamshelane nenkonzo egunyazisiweyo ye-ACCU-SCOPE
iziko okanye ufowunele i-ACCU-SCOPE ngo-1-888-289-2228 kwiziko lenkonzo eligunyazisiweyo elikufutshane nawe.
Ukukhanya kokukhanya akukhanyi ngokwaneleyo Ukungasebenzisi i-l ekhethiweyoamp.
Iqhosha lohlengahlengiso lokukhanya alilungiswanga kakuhle.
Sebenzisa n ekhethiweyo lamp.
Lungisa iqhosha lohlengahlengiso lokukhanya ngendlela echanekileyo.

EZIZINTO EZIZOHLUKENEYO

Intsimi ye view kwelinye iliso alilingani nelinye Umgama we-interpupillary awuchanekanga.
I-diopter ayilunganga.
Eyakho view akaqhelanga ukujonga ngemicroscope kunye ne-widefield eyepieces.
Lungisa umgama we-interpupillary.
Lungisa idayterter.
Xa ujonga i-eyepieces, zama ukujonga intsimi iyonke ngaphambi kokuba ugxile kuluhlu lwesampulu. Usenokukufumanisa kuluncedo
ukujonga phezulu nokumgama okomzuzwana phambi kokuba ujonge kwimicroscope kwakhona.
Ifestile yangaphakathi okanye i-fluorescence lamp ifanekisiwe. Ukukhanya okulahlekileyo kungena kwi-eyepieces kwaye kubonakaliswa kwikhamera.  Khupha / gubungela zombini izibonda zamehlo ngaphambi kokuba wenze umfanekiso.

UKULONDOLOZA

Nceda ukhumbule ukuba ungaze ushiye imakroskopu nazo naziphi na iinjongo okanye izibonda zamehlo zisusiwe kwaye soloko ukhusela imakroskopu ngesigqubuthelo sothuli xa ingasetyenziswa.

INKONZO

Imicroscopes ye-ACCU-SCOPE® zizixhobo ezichanekileyo ezifuna ukondliwa ngamaxesha athile ukuze zigcinwe zisebenza kakuhle kunye nokubuyekeza ukunxitywa kwesiqhelo. Ishedyuli eqhelekileyo yolondolozo lothintelo ngabasebenzi abaqeqeshiweyo iyacetyiswa kakhulu. Umsasazi wakho ogunyazisiweyo we-ACCU-SCOPE® unokulungiselela le nkonzo. Ukuba kukho iingxaki ezingalindelekanga kwisixhobo sakho, qhubeka ngolu hlobo lulandelayo:

  1. Qhagamshelana nomsasazi we-ACCU-SCOPE® othenge kuye imakroskopu. Ezinye iingxaki zinokusonjululwa ngokulula ngefowuni.
  2. Ukuba kuye kwafunyaniswa ukuba imakroskopu kufuneka ibuyiselwe kwi-ACCU-SCOPE® yakho okanye kwi-ACCU-SCOPE® ukuze ilungiswe iwaranti, pakisha isixhobo kwibhokisi yenqanawa ye-Styrofoam yokuqala. Ukuba awusenayo le bhokisi, pakisha imakroskopu kwibhokisi ekwaziyo ukumelana nokutyumza ubuncinane obuzii-intshi ezintathu zezinto ezifunxa umothuko eziyingqongileyo ukunqanda umonakalo osendleleni. I-microscope kufuneka isongelwe kwingxowa yeplastiki ukukhusela uthuli lwe-Styrofoam ekonakaliseni i-microscope. Ngalo lonke ixesha thumela imakroskopu imile ime nkqo; UNGAZE UTHUMELE IMASKROKOPU KWICAXA LAYO. I-microscope okanye icandelo kufuneka lithunyelwe ngenqanawa lihlawulelwe kwangaphambili kwaye lifakwe kwi-inshurensi.

ISIQINISEKISO SESIXHOSA ESIPHELELEYO
Le microscope kunye namacandelo ayo e-elektroniki aqinisekisiwe ukuba angabinaziphene kwizinto eziphathekayo kunye nokusebenza kwexesha leminyaka emihlanu ukususela kumhla we-invoyisi ukuya kumthengi wokuqala (umsebenzisi wokugqibela). I-LED lamps ziqinisekiswe ixesha elingangonyaka ukusuka kumhla we-invoyisi yoqobo ukuya kumthengi wokuqala (umsebenzisi wokugqibela). Unikezelo lombane lwemercury luqinisekisiwe ixesha elingangonyaka ukusuka kumhla we-invoyisi ukuya kumthengi wokuqala (umsebenzisi wokugqibela). Esi siqinisekiso asiwuquki umonakalo obangelwe kuthutho, ukusetyenziswa gwenxa, ukungahoywa, impatho-gadalala okanye umonakalo obangelwe yinkonzo engafanelekanga okanye ukuguqulwa kwabasebenzi benkonzo abavunyiweyo be-ACCU-SCOPE. Esi siqinisekiso asiquki nawuphi na umsebenzi wesiqhelo wokulungisa okanye nawuphi na omnye umsebenzi, ekulindeleke ngokusengqiqweni ukuba wenziwe ngumthengi. Ukunxiba okuqhelekileyo akubandakanywa kule waranti. Akukho xanduva luthathwayo ngenxa yokusebenza ngokunganelisiyo ngenxa yeemeko zokusingqongileyo ezifana nokufuma, uthuli, iikhemikhali ezonakalisayo, ukugalelwa kwe-oyile okanye ezinye izinto zangaphandle, ukuchitheka okanye ezinye iimeko ezingaphaya kolawulo lwe-ACCU-SCOPE INC. Esi siqinisekiso asibandakanyi naliphi na ityala yi-ACCU -SCOPE INC. ngelahleko elandelanayo okanye umonakalo kuyo nayiphi na imihlaba, efana (kodwa ingaphelelanga) ukungafumaneki koMsebenzisi wokugqibela wemveliso (s) phantsi kwewaranti okanye imfuneko yokulungisa iinkqubo zokusebenza. Ukuba kukho nasiphi na isiphene kwizinto eziphathekayo, ekusetyenzweni okanye kwinxalenye ye-elektroniki phantsi kwesi siqinisekiso, qhagamshelana nomthengisi wakho we-ACCU-SCOPE okanye i-ACCU-SCOPE 631-864-1000. Esi siqinisekiso silinganiselwe kwilizwekazi lase-United States of America. Zonke izinto ezibuyiswayo ukuze zilungiswe iwaranti kufuneka zithunyelwe kwimpahla ehlawulwa kwangaphambili kunye ne-inshurensi kwi-ACCU-SCOPE INC., 73 Mall Drive, Commack, NY 11725 - USA. Lonke ulungiso lwewaranti luya kubuyiselwa umthwalo ohlawulelwe ngaphambili nakweyiphi na indawo ekuyiwa kuyo ngaphakathi kwelizwekazi lase-United States of America, kuzo zonke iwaranti yokulungiswa kweendleko zokubuyisela iwaranti yangaphandle luxanduva lomntu ngamnye/inkampani ebuyisele impahla ukuze ilungiswe.
I-ACCU-SCOPE luphawu lwentengiso olubhalisiweyo lwe-ACCU-SCOPE INC., Commack, NY 11725

I-ACCU-SCOPE®
73 Mall Drive, Commack, NY 11725 
631-864-1000 (P)
631-543-8900 (F)
www.accu-scope.com
info@accu-scope.com
v071423

Amaxwebhu / Izibonelelo

I-ACCU SCOPE EXI-410 Series Inverted Microscope [pdf] Incwadi Yomyalelo
Uthotho lwe-EXI-410 yeMikroskopu eNgenelweyo, i-EXI-410, iMikroskopu eGuquliweyo, iMikroskopu eNgenelweyo, iMicroscope

Iimbekiselo

Shiya uluvo

Idilesi yakho ye-imeyile ayizupapashwa. Iindawo ezifunekayo ziphawulwe *