AC Input: 100-240Vac (for DA2-Type only)

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-2

User’s Manual

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-1

Features

  • Constant voltage PWM style output
  • Emergency lighting application is available according to IEC61347-2-13
  • Built-in active PFC function and class II design
  • No load power consumption <O.5W/ standby power consumption <O.5W(DA/DA2-type)
  • Fully encapsulated with IP67 level
  • Function options: 3 in 1 dimming (dim-to-off); DALI/DALl-2
  • Minimum dimming level 0.2% for DALI type
  • Typical lifetime>50000 hours and 5 years warranty

Applications

  • LED strip lighting
  • Indoor LED lighting
  • LED decorative lighting
  • LED architecture lighting
  • Industrial lighting
  • Type “HL” for use in class l, division 2 hazardous (classified) location.

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTlN.aspx

Description

PWM-120 series is a 120W AC/DC LED driver featuring the constant voltage mode with P WM style output, which is able to maintain the color temperature and the brightness homogeneity when driving all kinds of LED strips. PWM-120 operates from 90—305VAC and offers models with different rated voltage ranging between 12V and 48V. Thanks to the high efficiency up to 90.5%, with the fanless design, the entire series is able to operate for -40 C +90 C case temperature under free air convection. The entire series is rated with IP67 ingress protection level and is suitable to work for dry, damp or wet locations. PWM-120 is equipped with dimming function that varies the duty cycle of the output, providing great flexibility for LED strips applications.

Model Encoding

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-3

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-19

SPECIFICATION

MODEL PWM-120-12 PWM-120-24 PWM-120-36 PWM-120-48
 

 

 

 

OUTPUT

DC VOLTAGE 12V 24V 36V 48V
RATED CURRENT 10A 5A 3.4A 2.5A
RATED POWER 120W 120W 122.4W 120W
DIMMING RANGE 0 ~ 100%
PWM FREQUENCY (Typ.) 1.47kHz for Blank/DA-Type, 2.5kHz for DA2-Type
SETUP, RISE TIME Note.2

Note.9

500ms, 80ms/ 230VAC or 115VAC
HOLD UP TIME (Typ.) 16ms/230VAC or 115VAC
 

 

 

 

 

 

 

INPUT

VOLTAGE RANGE Note.3 90 ~ 305VAC         127 ~ 431VDC

(Please refer to “STATIC CHARACTERISTIC” section)

FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.97/115VAC, PF>0.96/230VAC, PF>0.93/277VAC @ full load

(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)

TOTAL HARMONIC DISTORTION THD< 20%(@load≧60%/115VAC, 230VAC; @load≧75%/277VAC)

(Please refer to “TOTAL HARMONIC DISTORTION” section)

EFFICIENCY (Typ.) 88.5% 90% 90% 90.5%
AC CURRENT (Typ.) 1.3A / 115VAC        0.65A / 230VAC        0.55A / 277VAC
INRUSH CURRENT (Typ.) COLD START 60A(twidth=520μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. NO. of PSUs on 16A CIRCUIT BREAKER 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT <0.25mA / 277VAC
NO LOAD/STANDBY POWER CONSUMPTION No load power consumption<0.5w for blank-type;standby power consumption<0.5W for DA-type/DA2-type
 

 

 

PROTECTION

OVERLOAD 108 ~ 130% rated output power
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT 12V/24V hiccup mode and 36V/48V shut down mode(including DA-type/except for DA2-type) Hiccup mode,recovers automatically after fault condition is removed (only for DA2-type)
 

OVER VOLTAGE

15 ~ 17V 28 ~ 34V 41 ~ 46V 54 ~ 60V
Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
 

 

ENVIRONMENT

WORKING TEMP. Tcase=-40~+90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP. Tcase=+90℃
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 45℃,except 0 ~ 40℃ for 12V)
VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
 

 

 

 

SAFETY & EMC

 

SAFETY STANDARDS Note.5

UL8750( type ”HL” )(except for 12DA type), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13,

BS EN/EN62384 independent, IP67,BIS IS 15885(Part2/Sec13)(for 12,24 Blank and DA2 Type), EAC TP TC 004, GB19510.1,GB19510.14 approved; Design refer to BS EN/EN60335-1; According to BS EN/EN61347-2-13 appendix J suitable for emergency installations(EL)(AC Input: 100-240Vac)(for DA2-Type only)

DALI STANDARDS IEC62386-101, 102, 207,251 for DA/DA2-Type only, Device type 6(DT6)
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC;  I/P-DA:1.5KVAC;  O/P-DA:1.5KVAC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION  Note.6 Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load≧60%) ; BS EN/EN61000-3-3,GB/T 17743, GB17625.1;EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Line 2KV), EAC TP TC 020
OTHERS MTBF 2243.7K hrs min.     Telcordia SR-332 (Bellcore) ;        228.7K hrs min.     MIL-HDBK-217F (25℃)
DIMENSION 191*63*37.5mm (L*W*H)
PACKING 0.97Kg; 15pcs/15.6Kg/0.87CUFT
 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.

2.  De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.

3.  Length of setup time is measured at first cold start. Turning ON/OFF the driver may lead to an increase of the setup time.

4.  The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

5.  This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃or less.

6.  Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com

7.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

8.  For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf

9.  Based on IEC 62386-101/102 DALI power on timing and interruption regulations, the set up time needs to test with a DALI controller which can support for DALI power on function, otherwise the set up time will be higher than 0.5 second for DA type.

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

DIMMING OPERATION

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-4

Dimming principle for PWM style output
Dimming is achieved by varying the duty cycle of the output current.

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-5

3 in 1 dimming function (for Blank-Type)

  • Apply one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
  • Dimming source current from power supply: 100μA (typ.)

Applying additive 0 ~ 10VDC

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-6

Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-7

Applying additive resistance:

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-8

Note :

  1. Min. duty cycle of output current is about 0.15%, and the dimming input is about 6KΩ or 0.6VDC, or 10V PWM signal with 6% duty cycle.
  2. The duty cycle of output current could drop down to 0% when dimming input is less than 6KΩ or less than 0.6VDC, or 10V PWM signal with duty cycle less than 6%.

DALI Interface (primary side; for DA/DA2-Type)

  • Apply DALI signal between DA+ and DA-.
  • DALI protocol comprises 16 groups and 64 addresses.
  • First step is fixed at 0.2% of output

OUTPUT LOAD vs TEMPERATURE

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-9

STATIC CHARACTERISTIC

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-10

POWER FACTOR (PF) CHARACTERISTIC

Tcase at 80℃

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-11

TOTAL HARMONIC DISTORTION

(THD)

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-12

EFFICIENCY vs LOAD

PWM-120 series possess superior working efficiency that up to 90.5% can be reached in field applications.

48V Model, Tcase at 80℃

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-13

LIFE TIME

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-14

Block Diagram

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-15

Mechanical Specification

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-16

Recommend Mounting Direction

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-17

Installation Manual

Connection for Blank-type

MEAN-WELL-PWM-120-12-Series-Constant-Voltage-PWM-Output-LED-Driver-fig-18

Cautions

  • Before commencing any installation or maintenance work, please disconnect the power supply from the utility. Ensure that it cannot be re-connected inadvertently!
  • Keep proper ventilation around the unit and do not stack any objects on it. Also, a 10-15 cm clearance must be kept when the adjacent device is a heat source.
  • Mounting orientations other than standard orientation or operating under high ambient temperature may increase the internal component temperature and require a de-rating in output current.
  • The current rating of an approved primary /secondary cable should be greater than or equal to that of the unit. Please refer to its specification.
  • For LED drivers with waterproof connectors, verify that the linkage between the unit and the lighting fixture is tight so that water cannot intrude into the system.
  • For dimmable LED drivers, make sure that your dimming controller is capable of driving these units.PWM series requires 0.15mA each unit.
  • Tc max. is identified on the product label. Please make sure that the temperature of the Tc point will not exceed the limit.
  • DO NOT connect “DIM- to -V”.
  • Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immersing in the water for over 30 minutes.
  • The power supply is considered a component that will be operated in combination with the final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

FAQ

  • Q: What should I do if the LED driver does not power on?
    A: Check the input power connection and verify that the voltage source is within the specified range.
  • Q: Can I connect multiple LEDs to one driver?
    A: It is recommended to follow the manufacturer’s guidelines on the maximum number of LEDs that can be connected to a single driver to ensure proper functionality and longevity of the LEDs.