Texnik xususiyatlari:

  • Model: PWM-120-12, PWM-120-24, PWM-120-36, PWM-120-48
  • DC voltage: 12V, 24V, 36V, 48V
  • Nominal oqim: 10A, 5A, 3.4A, 2.5A
  • Nominal quvvat: 120 Vt (barcha modellar uchun)
  • Karartma diapazoni: 0 - 100%
  • PWM chastotasi: Blank/DA-Type uchun 1.47kHz, 2.5kHz uchun
    DA2-turi
  • O'rnatish, ko'tarilish vaqti: 500ms, 80ms
  • jildtage Diapazon: 90 – 305VAC, 127 – 431VDC
  • Chastota diapazoni: 47 - 63Hz
  • Quvvat faktori: PF>0.97/115VAC, PF>0.96/230VAC,
    PF>0.93/277VAC @ to'liq yuk
  • Umumiy garmonik buzilish: THD<20%
  • Samaradorlik: 88.5% - 90%
  • Maks. 16A o'chirgichdagi PSU soni: 4 birlik (o'chirish moslamasi)
    B tipidagi o'chirgich) / 6 dona (C tipidagi o'chirgich).
    230VAC

Mahsulotdan foydalanish bo'yicha ko'rsatmalar:

1. O'rnatish:

– Kirish quvvati belgilangan AC kirish diapazoniga mos kelishiga ishonch hosil qiling
sizning modelingiz uchun.

– LED drayverini tegishli jildga ulangtage manba va
to'g'ri topraklama bilan ta'minlash.

2. Qoraytirish:

– Yoritishingizga qarab xiralashtirish diapazonini 0 dan 100% gacha sozlang
talablar.

– Optimal uchun belgilangan PWM chastotasi sozlamalaridan foydalaning
ishlash.

3. Elektr xavfsizligi:

– Barcha tegishli elektr xavfsizligi qoidalariga rioya qiling va
LED drayverini o'rnatish va ishlatish qoidalari.

– O'chirish to'xtatuvchisidagi PSUlarning maksimal sonidan oshmang
ortiqcha yuklamaslik uchun.

TSS:

Savol: LED drayveri yoqilmasa nima qilishim kerak?

Javob: Kirish quvvati ulanishini tekshiring va voltage
manba belgilangan oraliqda.

Savol: Bitta drayverga bir nechta LEDlarni ulashim mumkinmi?

Javob: Ishlab chiqaruvchining ko'rsatmalariga amal qilish tavsiya etiladi
bitta haydovchiga ulanishi mumkin bo'lgan LEDlarning maksimal soni
LEDlarning to'g'ri ishlashi va uzoq umr ko'rishini ta'minlash.

“`

120 Vt doimiy Voltage PWM chiqish LED drayveri

PWM-120 seriyali
Foydalanuvchi uchun qo'llanma

2

(faqat DA2 turi uchun)

AC kirish: 100-240Vac (faqat DA2 turi uchun)

IP67

IS 15885

TOMAS SAMUEL

TOMAS SAMUEL

05

12DA turidan tashqari

Arrow.com saytidan yuklab olingan.

File Nomi: PWM-120-SPEC 2024-09-25

120 Vt PWM chiqish LED drayveri

PWM-120 seriyali

XUSUSIYATLAR

MODEL

PWM-120-12

PWM-120-24

PWM-120-36

PWM-120-48

DC VOLTAGE

12V

24V

36V

NOMONLI HOZIRGI

10A

5A

3.4A

NOMINAL KUCH

120 Vt

120 Vt

122.4 Vt

Chiqish

KARARTARTIRISH ARZONASI

0 ~ 100%

PWM chastotasi (Tip.) Bo'sh/DA-turi uchun 1.47kHz, DA2.5-turi uchun 2kHz

O'RNATISH, Vaqtni ko'taring

Eslatma.2 Eslatma.9

500ms, 80ms/ 230VAC yoki 115VAC

KUTISH VAQTI (Tip.) 16ms/230VAC yoki 115VAC

VOLTAGE RANGE Eslatma.3

90 ~ 305VAC 127 ~ 431VDC (Iltimos, “STATIK XARAKTERISTIK” boʻlimiga qarang)

Chastotalar diapazoni 47 ~ 63Hz

QUVAT FAKTORI (tip)

PF>0.97/115VAC, PF>0.96/230VAC, PF>0.93/277VAC @ toʻliq yuk (Iltimos, “Kuch FAKTOR (PF) XARAKTERISTI” boʻlimiga qarang)

48V 2.5A 120Vt

UMUMIY GARMONIK BUZISH

THD< 20%(@load60%/115VAC, 230VAC; @load75%/277VAC) (Iltimos, “JAMIY GARMONIK DISTORTION” boʻlimiga qarang)

KIRISH

SAMARALIK (Tip.)

88.5%

90%

90%

AC CORRENT (Tipik)

1.3A / 115VAC 0.65A / 230VAC 0.55A / 277VAC

INRUSH CORRENT (Typ.) COLD START 60A(twidth=520s 50% Ipeak da o'lchanadi) 230VAC da; NEMA 410 bo'yicha

90.5%

MAX. YO'Q. 16A O'CHIRIShDA PSU'lar

4 birlik (B tipidagi o'chirgich) / 6 birlik (C tipidagi o'chirgich) 230VACda

OQISH OQIMI

<0.25mA / 277VAC

YUKLAMAGAN/Kutish rejimida quvvat iste'moli

Yuksiz quvvat iste'moli bo'sh turdagi uchun<0.5w; kutish rejimida quvvat sarfi<0.5W DA-turi/DA2-turi uchun

ORTA YUKLASH

108 ~ 130% nominal chiqish quvvati Hiqichoq rejimi, nosozlik bartaraf etilgandan keyin avtomatik ravishda tiklanadi

QISQA tutashuvdan himoyalanish
OVER OVERTAGE

12V/24V hiqichoq rejimi va 36V/48V oʻchirish rejimi (shu jumladan DA-turi/DA2-turidan tashqari) Hiqichoq rejimi, nosozlik bartaraf etilgandan keyin avtomatik ravishda tiklanadi (faqat DA2-turi uchun)

15 ~ 17 V

28 ~ 34 V

41 ~ 46 V

54 ~ 60 V

O/p jildni o'chirishtage, qayta tiklash uchun quvvatni yoqing

ORTA TEMPERATURE O'chirish o/p voltage, qayta tiklash uchun quvvatni yoqing

ISHLASH TOP.

Tcase=-40 ~ +90 (Iltimos, “CHISIB YUKLASH va TEMPERATURA” boʻlimiga qarang)

MAX. HAQIDA TEMP.

Tcase=+90

MUHIT ISHLASH NAMLIGI

20 ~ 95% RH kondensatsiz

SAQLASH HARORATI, NAMLIK -40 ~ +80, 10 ~ 95% RH

TEMP. KEFFICIENT

±0.03%/ (0 ~ 45, 0V uchun 40 ~ 12 dan tashqari)

VIBRASYON

10 ~ 500Hz, 5G 12 min./1 sikl, 72 daqiqalik davr. har biri X, Y, Z o'qlari bo'ylab

UL8750( “HL” turi )(12DA turidan tashqari), CSA C22.2 No 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13,

XAVFSIZLIK STANDARTLARI

Eslatma.5

BS EN/EN62384 mustaqil, IP67, BIS IS 15885(Part2/Sec13)(12,24 Blank va DA2 Type uchun), EAC TP TC 004, GB19510.1,GB19510.14 tasdiqlangan; Dizayn BS EN/EN60335-1 ga qarang; BS EN/EN61347-2-13 ga muvofiq

J ilovasi favqulodda qurilmalar uchun mos (EL)(AC Kirish: 100-240Vac)(faqat DA2-Tip uchun)

DALI STANDARTLARI

IEC62386-101, 102, 207,251 faqat DA/DA2-turi uchun, Qurilma turi 6(DT6)

XAVFSIZLIK VA MUSTAHKAM VOLTAGEI/PO/P: 3.75KVAC; I/P-DA: 1.5KVAC; O/P-DA: 1.5 KVAC

EMC

IZOLAYLANISHGA QARShILISH I/PO/P: 100M Ohm / 500VDC / 25/ 70% RH

EMC EMISSIYASI Eslatma.6 EMC Immuniteti

BS EN/EN55015, BS EN/EN61000-3-2 C sinfiga muvofiqlik (@load60%) ; BS EN/EN61000-3-3,GB/T 17743, GB17625.1;EAC TP TC 020
BS EN/EN61000-4-2,3,4,5,6,8,11 ga muvofiqligi; BS EN/EN61547, yengil sanoat darajasi (chiziq chizig‘i 2KV kuchlanish daxlsizligi), EAC TP TC 020

BOSHQA MTBF O'lchami

2243.7K soat min. Telcordia SR-332 (Bellcore); 191*63*37.5 mm (L*W*Y)

228.7K soat min. MIL-HDBK-217F (25)

QADOQLASH

0.97 kg; 15pcs / 15.6Kg / 0.87CUFT

1. Alohida ko'rsatilmagan barcha parametrlar 230VAC kirish, nominal oqim va 25 muhit haroratida o'lchanadi.

Izoh 2. Kam hajmli hajmda reytingni pasaytirish kerak bo'lishi mumkintages. Tafsilotlar uchun "STATIK XARAKTERISTIK" bo'limlariga qarang. 3. O'rnatish vaqtining uzunligi birinchi sovuq ishga tushirilganda o'lchanadi. Drayvni yoqish/o'chirish sozlash vaqtini ko'payishiga olib kelishi mumkin.

4. Haydovchi yakuniy jihozlar bilan birgalikda boshqariladigan komponent sifatida qaraladi. Chunki EMC ishlashi ta'sir qiladi

to'liq o'rnatish bilan yakuniy uskunalar ishlab chiqaruvchilari to'liq o'rnatish to'g'risida EMC Direktivini qaytadan kvalifikatsiya qilishlari kerak.

(https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf saytida mavjud) 5. Bu seriya Tcase, xususan, tc nuqtasi (yoki TMP, har bir DLC uchun) taxminan 50,000 yoki undan kam bo'lsa, >75 XNUMX soatlik ishlashning odatiy davomiyligiga javob beradi.

6. MEAN WELL's kafolat bayonotiga qarang webhttp://www.meanwell.com saytida 7. 3.5 m (1000 fut) dan yuqori ish balandligi uchun ventilyatorsiz modellarda atrof-muhit harorati 5/1000 m va fan modellarida 2000/6500 m gacha pasaytirish.

8. Har qanday dastur eslatmasi va IP suv o'tkazmaydigan funksiyani o'rnatish bo'yicha ehtiyot bo'lish uchun ishlatishdan oldin foydalanuvchi qo'llanmamizga qarang.

https://www.meanwell.com/Upload/PDF/LED_EN.pdf

9. Vaqt va uzilish qoidalari bo'yicha IEC 62386-101/102 DALI quvvati asosida sozlash vaqti DALI quvvatini yoqish funksiyasini qo'llab-quvvatlaydigan DALI kontrolleri bilan sinovdan o'tkazilishi kerak, aks holda sozlash vaqti 0.5 soniyadan yuqori bo'ladi. DA turi.

Mahsulot javobgarligidan voz kechish Batafsil ma'lumot uchun https://www.meanwell.com/serviceDisclaimer.aspx ga qarang.

Arrow.com saytidan yuklab olingan.

File Nomi: PWM-120-SPEC 2024-09-25

120 Vt PWM chiqish LED drayveri
KO'CHIRISH FAOLIYATI

PWM-120 seriyali

AC/L(jigarrang) AC/N(ko‘k)

PWM-120

PWM uslubidagi chiqish uchun karartma printsipi Karartma chiqish oqimining ish aylanishini o'zgartirish orqali erishiladi.
Chiqish DC oqimi ON

Io=0A

OFF TON
T

DIM+(Binafsharang)* DIM-(Pushti)** +V(Qizil)(DA-turi uchun jigarrang) -V(Qora)(DA-turi uchun ko‘k)
* DA/DA2 turi uchun Blank-Type DA+ uchun DIM+
* *DIM- Blank-Type DA uchun- DA/DA2-turi uchun

TON

Ish aylanishi (%) =

×100%

T

Chiqish PWM chastotasi: Blank/DA-Type uchun 1.47kHz, DA2.5-Type uchun 2kHz

3 in 1 xiralashtirish funksiyasi (Blank-Type uchun)
DIM+ va DIM- o'rtasidagi uchta metodologiyadan birini qo'llang: 0 ~ 10VDC yoki 10V PWM signali yoki qarshilik. Elektr ta'minotidan dimlash manba oqimi: 100A (tip.)

0 ~ 10VDC qo'shimchani qo'llash

+V +

LED chiziqlar

-V DIM+
DIM-


+ Qo'shimcha jildtage

“DIM- to -V” ni ulamang

+ -

10%

0.15%

0.6V 1V

Chiqish oqimining ish aylanishi (%)

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V Karartuvchi kirish: qoʻshimcha hajmtage

Qo'shimcha 10V PWM signalini qo'llash (chastota diapazoni 100Hz ~ 3KHz):

+V +

LED chiziqlar

-V DIM+
DIM-

Qo'shimcha PWM signali

“DIM- to -V” ni ulamang

+ -
10% 0.15%
6% 10%

Chiqish oqimining ish aylanishi (%)

100% 90% 80% 70% 60% 50% 40% 30% 20% 10%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Qoʻshimcha 10V PWM signalini xiralashtirish kirishining ish aylanishi

Arrow.com saytidan yuklab olingan.

File Nomi: PWM-120-SPEC 2024-09-25

120 Vt PWM chiqish LED drayveri

PWM-120 seriyali

Qo'shimcha qarshilikni qo'llash:

+V +

LED chiziqlar

-V DIM+
DIM-

Qo'shimcha qarshilik

“DIM- to -V” ni ulamang

+ -
10% 0.15%
6K/N 10K/N

Chiqish oqimining ish aylanishi (%)

100% 90% 80% 70% 60% 50% 40% 30% 20% 10%

0% Qisqa

10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N (N=sinxronlashtirilgan qisqartirish uchun haydovchi miqdori)
Karartma kiritish: qo'shimcha qarshilik

Eslatma: 1. Min. Chiqish oqimining ish aylanishi taxminan 0.15% ni tashkil qiladi va karartma kirishi taxminan 6K yoki 0.6VDC yoki 10% ish aylanishi bilan 6V PWM signalidir. 2. Xiralashgan kirish 0K dan kam yoki 6VDC dan kam yoki ish aylanishi 0.6% dan kam bo'lgan 10V PWM signalida chiqish oqimining ish aylanishi 6% gacha tushishi mumkin.

DALI interfeysi (asosiy tomon; DA/DA2-turi uchun) DA+ va DA- o'rtasida DALI signalini qo'llang. DALI protokoli 16 guruh va 64 manzildan iborat. Birinchi qadam mahsulotning 0.2% miqdorida belgilanadi

Arrow.com saytidan yuklab olingan.

File Nomi: PWM-120-SPEC 2024-09-25

YUK (%)

120 Vt PWM chiqish LED drayveri
CHISHIRISH YUKLANIShiga nisbatan TEMPERATURE

PWM-120 seriyali

100
Faqat 80 230VAC kirish
60 50 40
20

Faqat 12V

-40 -25

0

15

30

40 45 50

60

MUHIT HARORATI,Ta ()

70 (gorizontal)

YUK (%)

100
Faqat 80 230VAC kirish
60
40
20

-40 -25 0

20

45

65

75

85

90 (gorizontal)

Tcase ()

STATIK XUSUSIYAT

100 90 80 70 60 50 40
90 100 125 135 145 155 165 175 180 200 230 305
KIRISH VOLTAGE (V) 60 Gts past kirish hajmida pasaytirish keraktage.

Umumiy harmonik buzilish (THD)

48V modeli, Tcase 80 da

30%

25%

20%

277VAC

15%

230VAC

115VAC

10%

5%

0%

50%

60%

70%

80%

90%

100%

YUKLASH

SAMARADORLIK(%)

PF

KUCH FAKTORI (PF) XUSUSIYATLARI

80 yoshda

1 .0 0 0 .9 5 0 .9 0 0 .8 5 0 .8 0 0 .7 5 0 .7 0 0 .6 5 0 .6 0 0 .5 5 0 .5 0 0 .4 5 0 . 4 0 0 .3 5 0 .3 0
10%

20%

30%

40%

50%

60%

70%

80%

90% 100% (75 Vt)

YUKLASH

277V 230V 115V

SAMARALIK va yuk
PWM-120 seriyali yuqori ish samaradorligiga ega bo'lib, dala ilovalarida 90.5% gacha erishish mumkin. 48V modeli, Tcase 80 da

92 91 90 89 88 87 86 85 84 83 82 81 80
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

277V 230V 115V

YUKLASH

THD YUK (%)

Arrow.com saytidan yuklab olingan.

File Nomi: PWM-120-SPEC 2024-09-25

120 Vt PWM chiqish LED drayveri

PWM-120 seriyali

MUDDAT

UMR BOYI (Kh)

120

100

80

60

40

20

0

20

30

40

50

60

70

80

90

Tcase( )

Arrow.com saytidan yuklab olingan.

File Nomi: PWM-120-SPEC 2024-09-25

120 Vt PWM chiqish LED drayveri

PWM-120 seriyali

Blok diagrammasi

EMI filtri

I / P

&

REKTIFIYALAR

PFC davri

QUVATLARNI O'CHIRISH

OTP

OLP

PWM va PFC NAZORATI

RECTIFIERS &
FILTR

PFC fosc: 50~120KHz PWM fosc: 60~130KHz

OLP

QARARTIRISh BOSHQARMASI

Aniqlash davri

+V -V DIM+ DIM-

OVP

Mexanik spetsifikatsiya
Blank-turi

Ish raqami PWM-120

Birlik: mm Tolerantlik: ±1

300±20

AC/L(jigarrang) AC/N(ko‘k)

50±3 SJTW 18AWG×2C

5

191 5

63 31.5

2-4.5

T ishi tc

95.5

5
tc: Maks. Koson harorati

5

300±20

UL2464 18AWG×2C SJTW 14AWG×2C 50±3

DIM+(binafsha) DIM-(pushti) +V(qizil) -V(qora)

37.5

3

DA/DA2-turi

300±20

AC/L(jigarrang) AC/N(ko‘k)

50±3
SJOW 17AWG × 2C & H05RN-F 1.0 mm2

5

191 5

63 31.5

2-4.5

T ishi tc

95.5

5
tc: Maks. Koson harorati

5

300±20 UL2464 18AWG×2C SJOW 17AWG×2C 50±3 &H05RN-F 1.0mm2

DA+(binafsha) DA-(pushti) +V(jigarrang) -V(ko‘k)

37.5

3

Arrow.com saytidan yuklab olingan.

File Nomi: PWM-120-SPEC 2024-09-25

120 Vt PWM chiqish LED drayveri
O'rnatish yo'nalishini tavsiya eting
O'rnatish qo'llanma Blank-turi uchun ulanish

PWM-120 seriyali

AC/L(JINGIRG) AC/N(KO‘K)

DIM-(P-INK) +
DIM+(binafsharang)
-V(QORA) +
+V(QIZIL)

0~10Vdc yoki 10V PWM yoki qarshilik Dimmer yoki DALI Dimmer
LED tasma

Ogohlantirishlar Har qanday o'rnatish yoki ta'mirlash ishlarini boshlashdan oldin, iltimos, elektr tarmog'ini elektr tarmog'idan uzing. Ta'minlash
uni tasodifan qayta ulash mumkin emasligini! Jihoz atrofida to'g'ri shamollatilishini ta'minlang va uning ustiga biron bir narsa qo'ymang. Bundan tashqari, 10-15 sm masofani saqlash kerak
qo'shni qurilma issiqlik manbai hisoblanadi. Standart orientatsiyadan yoki yuqori muhit haroratida ishlaydigan o'rnatish yo'nalishlari ko'payishi mumkin
ichki komponentning harorati va chiqish oqimini pasaytirishni talab qiladi. Tasdiqlangan birlamchi/ikkilamchi kabelning joriy reytingi qurilmanikidan kattaroq yoki unga teng bo'lishi kerak. Iltimos, murojaat qiling
uning spetsifikatsiyasiga. Suv o'tkazmaydigan ulagichlari bo'lgan LED drayverlari uchun jihoz va yoritish moslamasi o'rtasidagi bog'liqlikni tekshiring
suv tizimga kirmasligi uchun mahkamlang. Kichraytiriladigan LED drayverlari uchun karartma boshqaruvchisi ushbu birliklarni boshqarishga qodir ekanligiga ishonch hosil qiling.PWM seriyali
har bir birlik uchun 0.15 mA talab qilinadi. Tc maks. mahsulot yorlig'ida ko'rsatilgan. Tc nuqtasi harorati chegaradan oshmasligiga ishonch hosil qiling. “DIM- to -V” ni ulamang. To'g'ridan-to'g'ri quyosh nuri ta'sirisiz ichki yoki tashqi foydalanish uchun javob beradi. Iltimos, 30 dan ortiq suvga botirmang
daqiqa. Elektr ta'minoti yakuniy uskunalar bilan birgalikda ishlaydigan komponent sifatida qaraladi. EMC beri
To'liq o'rnatish unumdorlikka ta'sir qiladi, yakuniy uskunalar ishlab chiqaruvchilari to'liq o'rnatish bo'yicha EMC direktivasini qayta kvalifikatsiya qilishlari kerak.

Arrow.com saytidan yuklab olingan.

File Nomi: PWM-120-SPEC 2024-09-25

Hujjatlar / manbalar

MEAN-WELL PWM-120-12 Series Constant Voltage PWM chiqish LED drayveri [pdf] Foydalanuvchi qo'llanmasi
PWM-120-12, PWM-120-24, PWM-120-36, PWM-120-48, PWM-120-12 seriyali doimiy hajmtage PWM Chiqish LED drayveri, PWM-120-12 Series, Constant Voltage PWM Chiqish LED drayveri, Voltage PWM chiqish LED drayveri, PWM chiqish LED drayveri, chiqish LED drayveri, LED drayveri

Ma'lumotnomalar

Fikr qoldiring

Sizning elektron pochta manzilingiz nashr etilmaydi. Majburiy maydonlar belgilangan *