2. Product Introduction

The DSO510 is a highly practical and cost-effective handheld oscilloscope developed by FNIRSI, targeting the maintenance and development education industries. This oscilloscope features a real-time sampling rate of 48MS/s, 10MHz bandwidth, and complete triggering functions (single, normal, auto). It can be used for both periodic analog signals and non-periodic digital signals, measuring up to ±400V voltage. It includes an efficient one-click AUTO function for displaying measured waveforms without complicated adjustments. Additionally, it features a multi-function signal generator (50KHz). The device is equipped with a 2.8-inch 320x240 resolution HD LCD screen and a built-in 1000mAh high-quality lithium battery, providing approximately 4 hours of continuous use when fully charged.

3. Panel Introduction

The DSO510 features a 2.8-inch display and various controls. The main components are:

4. Buttons Functions

ButtonOperationMain MenuOscilloscopeSignal GeneratorSetting
Wheel (Left)Move to the leftUpward selectionControl various parameters, function adjustment selectionNumerical position selectionDecrease volume/brightness
Wheel (OK)Short pressEnter interface/Enter/exit numerical valuesEnter current settings/Confirm current setting parameters
Long pressReturn main menu
Wheel (Right)Move to the rightDownward selectionControl various parameters, function adjustment selectionNumerical position selectionIncrease volume/brightness
AUTOShort press/Automatic measurement//
Long press/Auto calibration//
MODEShort press/Switch measurement modeReturnReturn
Long press/Parameter settings interface//
Up (▲)Short press/Upward selection/adjustment of parameters
Down (▼)Short press/Downward selection/adjustment of parameters
RUNShort pressRun/pause waveformEnable/disable output
Long press/Save waveform/
Power (⏻)Short pressPower on/Power off

Oscilloscope Parameter Settings Interface Buttons Functions

ButtonOperationWave-formParametersPersistenceImage
Wheel (OK)Short pressSwitch parametersTurn on/off parameters/Open image
Wheel (Left)Move to the leftSelect leftwardView previous image
Wheel (Right)Move to the rightSelect rightwardView next image
Up (▲)Short pressMove upward (in parameter interface, move to the previous column)
Down (▼)Short pressMove downward (in parameter interface, move to the next column)
MODELong pressEnter/exit parameter settings interface

5. Product Parameters

Sampling rate48MS/s
Bandwidth10M
Vertical sensitivity10mV/Div-10V/Div
Time Base Range50ns-20S
Voltage rangeX1: ±40V (Vpp:80V)
X10: ±400V (Vpp:800V)
Trigger ModeAutomatic/Normal/Single
Trigger EdgeRising edge/Falling edge
CouplingAC/DC
Square wave calibrationFrequency: 1K; Duty cycle: 50%; Amplitude: 3.3V

Signal Generator

Frequency0-50KHz
Duty cycle0-100% (rectangular and sawtooth waves)
Amplitude0.1-3.0V
WaveformsSine wave, rectangular wave, sawtooth wave, half wave, full wave, step wave, anti step wave, exponential rise, exponential drop, DC signal, multi tone, Sink pulse, Lorentz wave.

Others

Display2.8 inches/PPI:320*240
USB charging5V/1A
Lithium battery capacity1000mAh
Size99x68.3x19.5mm
Weight104g

Note: The size and weight are both manually measured, with slight errors. Please refer to the actual product for accuracy.

6. Screen Indication

6.1 Oscilloscope Interface

The oscilloscope interface displays the waveform and various parameters. Key indicators include:

  1. Vertical unit: Represents the voltage per large grid in the vertical direction.
  2. Trigger mode indicator icon: "Auto" for automatic triggering, "Single" for single triggering, "Normal" for normal triggering.
  3. Probe ratio: Must be consistent with the 1X/10X switch on the probe handle. If the probe is in 1X mode, the oscilloscope should also be set to 1X mode (1X measures 40V, 10X measures 400V).
  4. Input coupling method indicator icon: "AC" for AC coupling, "DC" for DC coupling.
  5. Trigger voltage indicator icon: Indicates the trigger voltage level.
  6. Trigger position indicator icon: Indicates the horizontal position of the trigger.
  7. Baseline indicator icon: Indicates the current position as 0V voltage.
  8. Horizontal time base: Represents the length of time per large grid in the horizontal direction.
  9. Run/pause indicator icon: "RUN" indicates running, "STOP" indicates pause.
  10. Trigger edge indicator icon: Shows the trigger edge (rising or falling).
  11. V H (Voltage/Horizontal): Left/right controls the time base; up/down controls the vertical sensitivity of the channel.
  12. Battery level: Indicates the current battery charge.

Additional controls related to trigger movement and waveform adjustment:

Note: These controls are switched via the MODE button.

6.2 Oscilloscope Parameter Settings Interface

Accessed by long-pressing the MODE button from the main oscilloscope interface. This interface allows setting and viewing various parameters:

  1. Waveform: Set coupling type, probe ratio, trigger mode, and trigger edge.
  2. Parameter: Toggle parameter display (frequency, period, positive duty cycle, negative duty cycle, positive pulse width, negative pulse width, maximum value, minimum value, peak-to-peak value, amplitude, RMS value, average value).
  3. Persistence: Set afterglow options: off, 500ms, 1s, ∞.
  4. Image: View saved images.

6.3 Signal Generator Interface

The signal generator interface allows configuration of the output signal:

  1. Waveforms selection: Choose from Sine Wave, Square Wave, Sawtooth Wave, Half-wave, Full Wave, Step Wave.
  2. Display of waveforms: Visual representation of the selected waveform.
  3. Frequency setting: Adjust the output frequency.
  4. Duty cycle setting: Adjust the duty cycle for rectangular and sawtooth waves.
  5. Amplitude setting: Adjust the output amplitude.
  6. Opening and closing of signal generator: Toggle output on/off (indicator turns red when closed).
  7. Battery level: Indicates the current battery charge.

6.4 Settings Interface

The settings interface provides options for customizing the device:

  1. Set single item selection: Navigate through Language, Sound and light, Startup on boot, Theme, Auto Shutdown, USB Sharing, About, Factory Reset.
  2. Specific settings details:
    1. Language: Chinese, English.
    2. Sound and light: Brightness: 25-100; Sound: 0-10.
    3. Startup on Boot: Turn off, oscilloscope, signal generator. This setting determines which function mode automatically starts upon boot.
    4. Theme: Blue, Yellow.
    5. Auto shutdown: Off, 15 minutes, 30 minutes, 1 hour.
    6. USB Sharing: After enabling, connect to a computer via USB to transfer pictures.
    7. About: Displays brand information and version number.
    8. Factory Reset: Resets all settings to factory defaults. A caution message warns that factory reset will undo all previous changes.

7. Firmware Update

To update the firmware:

  1. While the device is shut down, press and hold the Wheel (OK) button, then press the Power (⏻) button.
  2. Use a Type-C cable to connect the Type-C port on the board to a computer. A USB drive named "IAP" will appear on the computer.
  3. Drag the firmware file into the "IAP" USB drive. Once the firmware upgrade is complete, the device will automatically jump to the APP.

⚠ NOTICE

  • Firmware upgrade only supports Windows 10 and above systems.
  • During the upgrade process, keep pressing the power button until the file transfer is complete.

8. Points for Attention

9. Contact Us

For any questions, FNIRSI users can contact the company for a satisfactory solution and an extra 6 months warranty. FNIRSI encourages users to join their community.

Shenzhen FNIRSI Technology Co., LTD.

Address: West of Building C, Weida Industrial Park, Dalang Street, Longhua District, Shenzhen, Guangdong, China

Telephone: 0755-28020752

Website: www.fnirsi.cn

E-mail (Business): business@fnirsi.com

E-mail (Equipment Service): service@fnirsi.com

Execution Standard: GB/T 15289-2013

Models: DSO-510, DSO510, DSO510 Digital Oscilloscope, DSO510, Digital Oscilloscope, Oscilloscope

File Info : application/pdf, 32 Pages, 1.87MB

PDF preview unavailable. Download the PDF instead.

DSO-510 Manual ?v=1724116763

References

Adobe PDF library 16.07 Adobe Illustrator 27.0 (Windows)

Related Documents

Preview FNIRSI DSO510 Digital Oscilloscope Instruction Manual
Comprehensive instruction manual for the FNIRSI DSO510 Digital Oscilloscope, covering features, operation, specifications, firmware updates, and safety precautions for this handheld 10MHz bandwidth, 48MS/s sampling rate device with built-in signal generator.
Preview FNIRSI DSO510 Digital Oscilloscope Instruction Manual
This instruction manual provides detailed information for the FNIRSI DSO510 Digital Oscilloscope, a cost-effective handheld device with a 48MS/s real-time sampling rate, 10MHz bandwidth, and ±400V voltage measurement. Learn about its features, panel layout, button functions, product parameters, screen indications, firmware updates, and important usage precautions.
Preview FNIRSI DSO510 Digital Oscilloscope Instruction Manual
Comprehensive instruction manual for the FNIRSI DSO510 Digital Oscilloscope, covering product introduction, panel functions, button operations, technical parameters, screen indications, firmware updates, and important safety points. Learn how to operate and maintain your DSO510 oscilloscope.
Preview FNIRSI DSO510 Digital Oscilloscope User Manual
Comprehensive user manual for the FNIRSI DSO510 handheld digital oscilloscope, featuring 48MS/s real-time sampling, 10MHz bandwidth, multi-function signal generator, and a 2.8-inch LCD. Includes detailed operation, parameter settings, and firmware update instructions.
Preview FNIRSI DSO510 Digital Oscilloscope User Manual
Comprehensive user manual for the FNIRSI DSO510 Digital Oscilloscope, covering product introduction, panel layout, button functions, technical parameters, screen display, signal generator interface, settings, firmware updates, and safety precautions. Learn how to operate and maintain your DSO510.
Preview FNIRSI DSO153 Digital Oscilloscope: Instruction Manual & Specifications
Comprehensive instruction manual for the FNIRSI DSO153 handheld digital oscilloscope. Learn about its features, panel layout, button functions, technical parameters, screen indications, firmware updates, and contact information.
Preview FNIRSI-1014D Two-in-One Digital Oscilloscope and Signal Generator Product Instructions
The FNIRSI-1014D is a cost-effective two-in-one digital oscilloscope and signal generator, ideal for maintenance and R&D. It features a 1GSa/s real-time sampling rate, 100MHz dual analog bandwidth, comprehensive trigger functions (single, normal, auto), and a built-in DDS signal generator with 14 standard waveforms. The device includes a high-voltage protection module (up to 400V), a 7-inch 800x480 LCD, cursor measurement, and 1GB storage for up to 1000 screen captures and waveform data. It supports Lissajous graphics and FFT viewing for signal analysis and offers convenient USB connectivity for data sharing.
Preview FNIRSI DSO153 数字示波器使用说明书 - 数字示波器操作指南
FNIRSI DSO153是一款高实用性、高性价比的手持数字示波器,提供5MS/s采样率、1MHz带宽及多种触发功能。本说明书详细介绍了产品功能、面板操作、按键说明、参数指标及使用注意事项,是维修、研发和教育领域的理想工具。