FNIRSI DSO153 Digital Oscilloscope Instruction Manual
Model: DSO153
Notice to Users
- This manual provides detailed introductions to the product. Please read this manual carefully to ensure the product is in its best state.
- Please keep this manual properly.
- Do not use the instrument in flammable and explosive environments.
- Waste batteries and instruments cannot be disposed of together with household waste. Please dispose of them in accordance with relevant national or local laws and regulations.
- If there are any quality issues with the device or if you have any questions about using the device, please contact “FNIRSI” online customer service, and they will solve it for you in the first time.
1. Product Introduction
The DSO-153 is a highly practical and cost-effective handheld oscilloscope launched by FNIRSI, targeting the maintenance, development, and education industries. This oscilloscope features a real-time sampling rate of 5MS/s, 1MHz bandwidth, and a complete triggering function (single, normal, auto). It can be used for both periodic analog signals and non-periodic digital signals, and can measure voltages up to ±400V. With an efficient one-click AUTO function, it displays the measured waveform without complicated adjustments. Additionally, it includes a 10KHz signal generator. The device is equipped with a 2.8-inch 320 * 240 resolution HD LCD screen and a built-in 1000mAh high-quality lithium battery, providing approximately 4 hours of use when fully charged.
2. Panel Introduction
The FNIRSI DSO153 features the following components:
Key Components:
- DSO: Digital Storage Oscilloscope function.
- DDS: Direct Digital Synthesis (Signal Generator function).
- Reset hole: For system reset.
- Charging indicator light: Red when charging, green when fully charged.
- TYPE-C charging interface: For power input (5V/1A).
- Power button: Turns the device on/off.
- Square wave calibration: For calibrating the oscilloscope.
- Wheel button: Navigates menus and confirms selections (Left, OK, Right).
- AUTO button: Initiates automatic measurement or mode switching.
- MODE button: Switches between different operating modes (e.g., Oscilloscope, Signal Generator).
- Up button: Navigates up or adjusts values.
- Down button: Navigates down or adjusts values.
- RUN button: Starts or pauses waveform acquisition/output.
3. Buttons Functions
The functions of the buttons vary depending on the operation (short press, long press) and the current menu or mode.
Button | Operation | Main Menu | Oscilloscope | Signal Generator | Setting |
---|---|---|---|---|---|
⬆️ (Up) | Short press | Select Up | Control the function adjusting of various parameters | Not enter value settings: waveform select; Enter value settings: value bit select | Setting select |
⚙️ (Menu/Mode) | Short press | Enter menu | 50% | enter/exit values | enter/exit values settings in the sound and light values. In restoring factory settings, restore. |
Long press | Return to main menu | ||||
⬇️ (Down) | Short press | Select down | Control the function adjusting of various parameters | Not enter value Settings: waveform select; Enter value settings: value bit select | Setting select |
AUTO | Short press | / | Auto measurement | / | / |
Long press | / | / | / | / | |
MODE | Short press | / | Auto/Single/Normal switch | / | / |
Long press | / | Rising and falling edges switch | / | / | |
⬆️ (Up) | Short press | / | parameter adjustment | / | |
⬇️ (Down) | Short press | / | parameter adjustment | / | |
RUN | Short press | / | Run/Pause waveform | Turn on/off output | / |
Long press | / | Display/disable measurement parameters | / | / | |
⚡ (Power) | Short press | / | Power off | ||
Long press | / | Power on |
4. Product Parameters
Parameter | Value | Parameter | Value |
---|---|---|---|
Sampling rate | 5MS/s | Signal generator: Frequency | 0-10KHz |
Bandwidth | 1M | Duty cycle | 0-100% (rectangular and sawtooth waves) |
Vertical sensitivity | 10mV/Div-10V/Div | Amplitude | 0.1-3.3V |
Time Base Range | 500ns-20S | Waveforms | Sine wave, rectangular wave, sawtooth wave, half wave, full wave, step wave, anti step wave, noise wave, exponential rise, exponential drop, DC signal, multi tone, Sink pulse, Lorentz wave. |
Voltage range | X1: ±40V (Vpp:80V) X10: ±400V (Vpp:800V) | Others: Display | 2.8 inches/PPI:320*240 |
Trigger Mode | Automatic/Normal/Single | USB charging | 5V/1A |
Trigger Edge | Rising edge /falling edge | Lithium battery capacity | 1000mAh |
Coupling | AC/DC | Size | 99x68.3x19.5mm |
Square wave calibration | Frequency: 1K; Duty cycle: 50%; Amplitude: 3.3V | Weight | 100g |
Note: The size and weight are both manually measured, with slight errors; please refer to the actual product for accuracy.
5. Screen Indication
Main Menu
- Oscilloscope
- Signal Generator
- Settings
Oscilloscope Interface
Interface Indicators:
- Vertical unit: Represents the voltage scale per grid division in the vertical direction.
- Probe ratio: Must be consistent with the probe's 1X/10X switch setting. If the probe is set to 1X, the oscilloscope should also be set to 1X (measuring 40V per division). If set to 10X, it measures 400V per division.
- Horizontal time base: Represents the time duration per grid division in the horizontal direction.
- Input coupling method indicator: AC indicates AC coupling, DC indicates DC coupling.
- Trigger voltage indicator: Shows the voltage level for triggering.
- Trigger position indicator: Indicates the position of the trigger point.
- Baseline indicator: Shows the current position as 0V voltage.
- Run/pause indicator: RUN indicates the waveform is being captured, STOP indicates it is paused.
- Trigger mode indicator: Auto represents automatic triggering, Single represents single triggering, Normal represents normal triggering.
- Trigger edge indicator: Indicates whether triggering occurs on the rising or falling edge of the signal.
- Signal generator on/off indicator: Shows the status of the signal generator.
- Battery level: Displays the remaining battery charge.
Signal Generator Interface
Interface Indicators:
- Waveforms selection: Choose from Sine Wave, Square Wave, Sawtooth wave, Half-wave, Full Wave.
- Display of waveforms: Shows the selected waveform.
- Frequency setting: Adjusts the signal frequency (e.g., 01000 Hz).
- Duty cycle setting: Adjusts the duty cycle percentage (e.g., 050%).
- Amplitude setting: Adjusts the signal amplitude (e.g., 3.3 V).
- Opening and closing of signal generator: Control button, grayed out when closed.
- Battery level: Displays the remaining battery charge.
Settings Interface
1. Single Item Selection
Users can select and configure individual settings:
- Language
- Sound and light settings
- Startup behavior
- Theme
- Automatic Shutdown
- About
- Restore Factory Settings
2. Specific Settings Details
- Language: Supports Chinese, English, Russian, Japanese, Spanish, Portuguese, German, Korean.
- Sound and light settings: Brightness can be set from 25-100; Sound level from 0-10.
- Start up: Options include turning off, starting in oscilloscope mode, or starting in signal generator mode. This determines the default function mode upon startup.
- Theme settings: Available themes include blue and yellow.
- Automatic shutdown: Options are off, 15 minutes, 30 minutes, or 1 hour.
- About: Displays brand information and version number.
- Restore factory settings: Resets the device to its default configuration.
Device Information:
- Brand: FNIRSI
- Version: V01
- Model: DSO-153
- Manufacturer: Shenzhen FNIRSI Technology Co., LTD.
- Website: http://www.fnirsi.cn
6. Firmware Update
Follow these steps to update the device's firmware:
- With the device shut down, press and hold the ⬇️ button, then press the power button.
- Connect the device to a computer using a Type-C cable. A USB drive named "IAP" should appear on the computer.
- Copy the firmware file into the "IAP" USB drive. Once the firmware upgrade is completed, the device will automatically jump to the application.
Notice:
- Firmware upgrades are supported only on computers running Windows 10 and above systems.
- During the upgrade process, keep pressing the power button until the file transfer is complete.
7. Points for Attention
- After receiving the device, please use it when fully charged.
- When using the oscilloscope, pay attention to the selection of the gear (range/sensitivity), and ensure it is consistent with the gear of the probe.
- When measuring high voltage, do not touch any metal parts of the oscilloscope to avoid the risk of electric shock.
- Try not to conduct a high-voltage test while the device is charging.
- When calibrating, it is necessary to unplug the BNC probe or short circuit the positive and negative terminals of the probe.
- USB firmware upgrades only support WIN10 and above. It is prohibited to drag files other than the released firmware, as this may cause irreparable consequences.
- Please charge using the voltage within the specifications provided in the instruction manual.
8. Contact Us
Any FNIRSI users with questions are promised a satisfactory solution and an extra 6 months warranty as thanks for their support!
FNIRSI has also created an interesting community; users are welcome to contact FNIRSI staff to join.
Shenzhen FNIRSI Technology Co., LTD.
Address: West of Building C, Weida Industrial Park, Dalang Street, Longhua District, Shenzhen, Guangdong
E-mail: fnirsiofficial@gmail.com (Business) / fnirsiofficialcs@gmail.com (Equipment service)
Tel: 0755-28020752 / +8613536884686
Web: www.fnirsi.cn