Ecotap Duo Wallcharger FR
A brand of Legrand
Product Overview
An image shows the Ecotap Duo Wallcharger FR, a white electric vehicle charging station with two charging ports, mounted on black stands, positioned next to the rear of a white electric car.
The Ecotap Duo Wallcharger FR is an electric vehicle charging station designed for efficient and reliable charging. It offers robust specifications for both general and electrical characteristics, as well as environmental and electromagnetic compatibility.
Specifications
General Characteristics
References (FR) | 55483702 / 55483703 |
Dimensions H x W x D (mm) | 532mm x 332mm x 184mm |
Material | 3.7 mm Steel |
Standard Color | Body: Ral 7011 / Cover: Ral 9016 |
Steel Treatment | Anti-corrosion (KTL) and powder coating |
Weight (kg) | 20 kg |
Number of charging points | 2 |
Socket | Type E/F and domestic socket |
Cable | Type 2 |
Socket Outlet | Type 2, Type 2 + type E/F for 55483702 / 55483703 |
Cable | Type 2 |
Electrical Characteristics
Power per outlet | 0 to 22 kW |
Service Voltage (Ue) / Rated Current (In A, In C) | Single-phase wiring, phase + N 230V~ from 0 to 32A (determined at 20°C) Three-phase wiring, 3 phases + N 400V~ from 16 to 32A (determined at 20°C) |
Impulse withstand voltage (Uimp) | 4kV |
Insulation voltage (Ui) | 230V single-phase 500V three-phase |
Frequency (fn) | 50Hz/60Hz |
Rated voltage | 1 phase + N: 230V - 3 phases + N: 400V |
Voltage tolerance (V) Independent of vehicle requirements | 195V - 265V |
Integrated protection system on the charging station | Type gG 63A fuse |
Integrated protection system per charging point | MCB 40A curve C RCD 40A 30mA Type B |
Conditional short-circuit current | 6000A IEC/EN 60898-1 10kA IEC/EN 60947-2 |
Admissible thermal stress in case of short-circuit | 16,000 A²s |
Network connection | Phase/Neutral/Ground on screw terminals 2.5 to 16 mm² rigid H07 V R/U or flexible H07 V K with ferrule. Charging station permanently connected to the AC power grid. |
Charging type | Mode 3 charging station equipped with a locking system for mode 3 |
Vehicle connection Mode 3 connection socket | Type 2 3P+N (single-phase compatible) with pilots conforming to IEC 62191-1 and IEC 62196-2 standards. Use only a manufacturer-approved plug with silver-plated contacts. The use of extension cords and adapters is prohibited. |
Vehicle connection Mode 2 connection socket | Type E/F domestic 2P+E (16A-250V) according to local regulations. The use of extension cords and adapters is prohibited. |
Phase rotation on channel 2 (right side) | In the case of single-phase wiring (Ph+N) on the power supply. Channel 2 will not be able to start charging sessions until the phase rotation between the contactor and the socket is manually cancelled. |
AC meters | MID certified, class B according to EN 50470-1, -3 |
Back office protocol | OCPP 1.6 Json |
Positioning | GPS |
Ethernet Connectivity | RJ45 Connector |
Environment
Operating temperature | -25°C / +50°C |
Storage temperature | -25°C / +80°C |
Relative humidity | 0 to 90% non-condensing |
Protection index / IP rating | IP 54 (IEC 60529), IK 10 (EN 62262) Connected or not |
Noise level | < 40 dBA at 1m |
Product | IEC 61851-1, IEC TS 61439-7 (AEVCS) |
Installation | Indoor or outdoor, limited access area, intended for use by ordinary persons (DBO), cabinet (wall) mounting, pollution degree 3, TNS, TT, compatible earthing. In case of IT earthing, this can be locally modified by adding an isolation transformer. |
Electrical safety | Class 1 IEC 61140 |
Electromagnetic Compatibility
European standards | Low Voltage Directive 2014 / 35EU / EMC Directive: 2014 / 30 / EU |
Radio technology type | GSM 2G/3G/4G, GPRS, RFID |
Suitable charging cards | Mifare, Ntag and iCODE SLI cards |