General Specifications
Attribute | Value |
---|---|
Reference Number | 55483702 / 55483703 |
Dimensions (H x W x D) | 532mm x 332mm x 184mm |
Housing Material | Steel 3.7 mm |
Standard Color | Body: RAL 7011 / Shield: RAL 9016 |
Steel Treatment | Anti-corrosion (KTL) and powder coating |
Weight | 20 kg |
Number of Charging Points | 2 |
Socket Type | Type E/F and household plug |
Cable | Type 2 |
Socket Type (Additional) | Type 2, Type 2 + Type E/F for 55483702 / 55483703 |
Cable (Additional) | Type 2 |
Electrical Specifications
Attribute | Value |
---|---|
Output Power per Charging Point | 0 to 22 kW |
Operating Voltage (Ue) / Current Ratings (In A, In C) | Single-phase wiring, Phase + N 230V~ from 0 to 32A (measured at 20°C) Three-phase wiring, 3 phases + N 400V~ from 16 to 32A (measured at 20°C) |
Impulse Voltage (Uimp) | 4kV |
Insulation Voltage (Ui) | 230V single-phase, 500V three-phase |
Frequency (fn) | 50Hz/60Hz |
Nominal Voltage | 1 phase + N: 230V - 3 phases + N: 400V |
Voltage Tolerance (V) | 195V - 265V (regardless of vehicle requirements) |
Integrated Safety System (Charging Station) | Fuse type gG 63A |
Integrated Safety System (per Charging Point) | MCB 40A curve C RCD 40A 30mA Type B |
Conditional Short-Circuit Current | 6000A IEC/EN 60898-1, 10kA IEC/EN 60947-2 |
Permissible Thermal Short-Circuit Current | 16,000 A²s |
Connection to Power Supply | Phase/Neutral/Earth on 2.5 to 16 mm² screw terminals, rigid HO7 V R/U or flexible H07 V K with sleeve. Charging station permanently connected to the AC power grid. |
Charging Type | Mode 3 charging terminal equipped with a locking system for Mode 3 |
Vehicle Connection Mode 3 | Type 2 3P+N (single-phase compatible) with pilots complying with IEC 62191-1 and IEC 62196-2. Only use a manufacturer-approved plug with silver-plated contacts. Use of extension cords and adapters is prohibited. |
Vehicle Connection Mode 2 | Type E/F household 2P+E (16A-250V) depending on local regulations. Use of extension cords and adapters is prohibited. |
Phase Rotation on Channel 2 (Right Side) | In the case of single-phase wiring (Ph+N) on the power source. Channel 2 cannot start charging sessions until the phase rotation between the contactor and the socket is manually reversed. |
AC Meters | MID-certified, Class B according to EN 50470-1, -3 |
Back Office Protocol | OCPP 1.6 Json |
Positioning | GPS |
Ethernet Connectivity | RJ45 connector |
Environment
Attribute | Value |
---|---|
Operating Temperature | -25°C / +50°C |
Storage Temperature | -25°C / +80°C |
Relative Humidity | 0 to 90% without condensation |
Protection Class | IP 54 (IEC 60529), IK 10 (EN 62262) Connected or not |
Sound Level | < 40 dBA / 1m |
Product Standards | IEC 61851-1, IEC TS 61439-7 (AEVCS) |
Installation | Indoors or outdoors, limited access zone, intended for use by ordinary persons (DBO), mounting in cabinet (wall mounting), pollution degree 3, TNS, TT, compatible earthing system. In an IT earthing system, this can be locally modified by adding an isolation transformer. |
Electrical Safety | Class 1 IEC 61140 |
Electromagnetic Compatibility
Attribute | Value |
---|---|
European Standards | Low Voltage Directive 2014 / 35EU / EMC Directive: 2014/30/EU |
Radio Technology Type | GSM 2G/3G/4G, GPRS, RFID |
Suitable Charging Cards | Mifare, Ntag and iCODE SLI cards |
Contact Information
Ecotap B.V.
Kruisbroeksestraat 23
5281 RV Boxtel
+31(0) 411 210 210
info@ecotap.nl