Specifications
General Characteristics
Characteristic | Details |
---|---|
References | 55161800 / 55161100 / 55161600 / 55321800 / 55321100 / 55321600 / 55081800 / 55081100 / 55081600 / 55081602 / 55081102 / 55081801 / 55320014 / 55320013 / 55320012 / 55321604 |
References (Eichrecht) | 55451800 / 55451100 / 55451600 |
References (FR) | 55483702 / 55483703 |
Dimensions (H x W x D) | 800 x 220 x 200 mm |
Material | Steel 2.2 mm |
Standard Color |
Body: Ral 6018 / Cover: Ral 9016 for 55161800 / 55321800 / 55451800 / 55081800 / 55081801 / 55320014 / 55320013 / 55160012 Body: Ral 7011 / Cover: Ral 9016 for 55161100 / 55321100 / 55451100 / 55483702 / 55081100 / 55483703 / 55081102 Body: Ral 9016 / Cover: Ral 9016 for 55161600 / 55321600 / 55451600 / 55081600 / 55081602 / 55321604 |
Steel Treatment | Anti-corrosion (KTL) and powder coating |
Weight | 21kg for 55451800 / 55451100 / 55451600 / 55483702 / 55081800 / 55081100 / 55081600 / 55483703 / 55081602 / 55081102 / 55081801 25kg for 55161800 / 55161100 / 55161600 / 55321800 / 55321100 / 55321600 / 55320014 / 55320013 / 55160012 / 55321604 |
Number of Charging Points | 2 |
Socket Type | Type 2, Type 2 + Type E/F for 55483702 / 55483703 |
Cable Type | Type 2 |
Electrical Characteristics
Characteristic | Details |
---|---|
Power per Socket | 0 to 22 kW for 55483702 / 55483703 / 55451800 / 55451100 / 55451600 / 55081800 / 55081801 / 55081100 / 55081101 / 55081600 / 55081601 / 55321800 / 55321801 / 55321100 / 55321101 / 55321600 / 55321601 / 55320013 / 55320014 0 to 11 kW for 55161800 / 55161801 / 55161100 / 55161101 / 55161600 / 55161601 / 55160011 / 55160012 |
Operating Voltage / Rated Current (Charger) | Single-phase wiring, phase + N 230V~ from 0 to 63A (determined at 20°C) Three-phase wiring, 3 phases + N 400V~ from 0 to 63A (determined at 20°C) |
Operating Voltage / Rated Current (per Charging Point) | Single-phase wiring, phase + N 230V~ from 0 to 32A (determined at 20°C) Three-phase wiring, 3 phases + N 400V~ from 0 to 32A (determined at 20°C) |
Impulse Withstand Voltage (Uimp) | 4kV |
Insulation Voltage (Ui) | 230V single-phase / 500V three-phase |
Frequency (fn) | 50Hz/60Hz |
Rated Voltage | 1 phase + N: 230V - 3 phases + N: 400V |
Voltage Tolerance (V) | 195V - 265V |
Integrated Protection (Station) | Type gG 63A fuse |
Integrated Protection (per Point) | Type gG 32A fuse + RCD 40A 30mA Type B |
Conditional Short-Circuit Current | 100kA IEC/EN 60898-1 |
Admissible Thermal Stress (Short Circuit) | 16,000 A²s |
Network Connection | Phase/Neutral, rigid cable, 2.5 to 16 mm², screw terminals H07 V R/U. Earth, rigid cable, 2.5 to 25mm², screw terminals H07 V R/U. |
Charging Type | Mode 3 charging station equipped with a locking system for mode 3 |
Vehicle Connection Details
Mode 3 Socket
Type 2 3P+N (single-phase compatible) with pilots conforming to IEC 62191-1 and IEC 62196-2 standards. Use only a manufacturer-approved plug with silver-plated contacts. The use of extension cords and adapters is prohibited.
Mode 2 Socket
Domestic Type E/F 2P+E (16A-250V) according to local regulations. The use of extension cords and adapters is prohibited.
Mode 3 Attached Cable Connector
Type 2 3P+N (single-phase compatible) with pilots conforming to IEC 62191-1 and IEC 62196-2 standards. The use of extension cords and adapters is prohibited.
Cable lengths:
- Models 55161800, 55161100, 55161600: 4m spiral 3x16A
- Model 55160012: 4m straight 3x16A
- Model 55321604: 4m straight 3x32A
- Models 55321800, 55321100, 55321600, 55320014, 55320013: 8m straight 3x32A
Phase Rotation (Channel 2)
In the case of single-phase wiring (Ph+N) on the power supply. Channel 2 cannot start charging sessions until the phase rotation between the contactor and the socket is manually canceled.
Ancillary Features
Feature | Details |
---|---|
AC Meters | Certified MID, Class B according to EN 50470-1, -3 |
Back Office Protocol | OCPP 1.6 Json |
Positioning | GPS |
Ethernet Connectivity | RJ45 connector for 55451800 / 55451100 / 55451600 / 55483703 / 55081602 / 55081102 / 55081801 / 55320014 / 55160012 |
Environment
Parameter | Value |
---|---|
Operating Temperature | -25°C to +50°C |
Storage Temperature | -25°C to +80°C |
Relative Humidity | 0 to 90% non-condensing |
Protection Index | IP 54 (IEC 60529), IK 10 (EN 62262) |
Noise Level | < 40 dBA at 1m |
Product & Compliance
Aspect | Details |
---|---|
Product Standard | IEC 61851-1, IEC TS 61439-7 (AEVCS) |
Installation | Indoor or outdoor, limited access area, intended for use by ordinary persons (DBO), cabinet (wall) mounting, pollution degree 3, TNS, TT, compatible earthing. In case of IT earthing, this can be modified locally by adding an isolation transformer. |
Electrical Safety | Class 1 IEC 61140 |
European Standards | Low Voltage Directive 2014/35EU / EMC Directive: 2014/30/EU |
Radio Technology Type | GSM 2G/3G/4G, GPRS, RFID |
Suitable Charging Cards | Mifare, Ntag and iCODE SLI cards |