Ecotap Duo Wallcharger
A brand of Legrand
Product Overview
An image shows the Ecotap Duo Wallcharger, a vertical white charging unit, mounted on a wall. To the left, the rear section of a white electric car is visible.
The Duo Wallcharger is a product from Ecotap, a brand of Legrand.
Contact information: www.ecotap.nl, info@ecotap.nl
General Characteristics
Characteristic | Details |
---|---|
Reference Number | 55161800 / 55161100 / 55161600 / 55321800 / 55321100 / 55321600 / 55081800 / 55081100 / 55081600 / 55081602 / 55081102 / 55081801 / 55320014 / 55320013 / 55320012 / 55321604 |
Reference Number (Calibration) | 55451800 / 55451100 / 55451600 |
Reference Number (FR) | 55483702 / 55483703 |
Dimensions (H x W x D) mm | 800 x 220 x 200 |
Housing Material | Steel 2.2 mm |
Standard Color | Body: Ral 6018 / Shield: Ral 9016 for 55161800 / 55321800 / 55451800 / 55081800 / 55081801 / 55320014 / 55320013 / 55160012 Body: Ral 7011 / Shield: Ral 9016 for 55161100 / 55321100 / 55451100 / 55483702 / 55081100 / 55483703 / 55081102 Body: Ral 9016 / Shield: Ral 9016 for 55161600 / 55321600 / 55451600 / 55081600 / 55081602 / 55321604 |
Steel Treatment | Anti-corrosion (KTL) and powder coating |
Weight (kg) | 21kg for 55451800 / 55451100 / 55451600 / 55483702 / 55081800 / 55081100 / 55081600 / 55483703 / 55081602 / 55081102 / 55081801 25kg for 55161800 / 55161100 / 55161600 / 55321800 / 55321100 / 55321600 / 55320014 / 55320013 / 55160012 / 553216048 |
Number of Charging Points | 2 |
Connector | Type 2, Type 2 + Type E/F for 55483702 / 55483703 |
Cable | Type 2 |
Electrical Characteristics
Characteristic | Details |
---|---|
Output Power per Charging Point | 0 to 22 kW for 55483702 / 55483703 / 55451800 / 55451100 / 55451600 / 55081800 / 55081801 / 55081100 / 55081101 / 55081600 / 55081601 / 55321800 / 55321801 / 55321100 / 55321101 / 55321600 / 55321601 / 55320013 / 55320014 0 to 11 kW for 55161800 / 55161801 / 55161100 / 55161101 / 55161600 / 55161601 / 55160011 / 55160012 |
Operating Voltage (Ue) / Rated Current (In A) for Charger | Single-phase cabling, Phase + N 230V~ from 0 to 63A (specified at 20°C) Three-phase cabling, 3 phases + N 400V~ from 0 to 63A (specified at 20°C) |
Operating Voltage (Ue) / Rated Current (In A) per Charging Point | Single-phase cabling, Phase + N 230V~ from 0 to 32A (specified at 20°C) Three-phase cabling, 3 phases + N 400V~ from 0 to 32A (specified at 20°C) |
Impulse Voltage (Uimp) | 4kV |
Insulation Voltage (Ui) | 230V single-phase, 500V three-phase |
Frequency (fn) | 50Hz/60Hz |
Nominal Voltage | 1 phase + N: 230V - 3 phases + N: 400V |
Voltage Tolerance (V) regardless of vehicle requirements | 195V - 265V |
Integrated Safety System on Charging Station | Fuse type gG 63A |
Integrated Safety System per Charging Point | Fuse Type gG 32A + RCD 40A 30mA Type B |
Conditional Short-Circuit Current | 100kA IEC/EN 60898-1 |
Permissible Thermal Short-Circuit Current | 16 000 A²s |
Connection to Power Grid | Phase/Neutral, rigid cable, 2.5 to 16 mm², screw terminals H07 V R/U Earth, rigid cable, 2.5 to 25 mm², screw terminals H07 V R/U |
Charging Type | Mode 3 charging terminal equipped with a locking system for Mode 3 |
Vehicle Connection Details
Connection Type | Details |
---|---|
Vehicle Connection Mode 3 Connector (55451800 / 55451100 / 55451600 / 55483702 / 55081800 / 55081100 / 55081600 / 55483703 / 55081602 / 55081102 / 55081801) | Type 2 3P+N (single-phase compatible) with pilots compliant with IEC 62191-1 and IEC 62196-2. Use only a manufacturer-approved plug with silver-plated contacts. Use of extension cords and adapters is prohibited. |
Vehicle Connection Mode 2 Connector (55483702 / 55483703) | Type E/F household 2P+E (16A-250V) depending on local regulations. Use of extension cords and adapters prohibited. |
Vehicle Connection Mode 3 Attached Cable Connector (55161800 / 55161100 / 55161600 / 55321800 / 55321100 / 55321600 / 55320014 / 55320013 / 55160012 / 55321604) | Type 2 3P+N (single-phase compatible) with pilots compliant with IEC 62191-1 and IEC 62196-2. Use of extension and adapter prohibited. 55161800 / 55161100 / 55161600: 4m coiled 3x16A 55160012: 4m straight 3x16A 55321604: 4m straight 3x32A 55321800 / 55321100 / 55321600 / 55320014 / 55320013: 8m straight 3x32A |
Phase Rotation on Channel 2 (right side) | In case of single-phase cabling (Ph+N) on the power source. Channel 2 cannot start charging sessions until the phase rotation between the contactor and the socket is manually corrected. |
AC Meters | MID-certified, Class B according to EN 50470-1, -3 |
Back Office Protocol | OCPP 1.6 Json |
Positioning | GPS |
Ethernet Connectivity | RJ45 connector for 55451800 / 55451100 / 55451600 / 55483703 / 55081602 / 55081102 / 55081801 / 55320014 / 55160012 |
Environment
Characteristic | Details |
---|---|
Operating Temperature | -25°C / +50°C |
Storage Temperature | -25°C / +80°C |
Relative Humidity | 0 to 90% without condensation |
Protection Class | IP 54 (IEC 60529), IK 10 (EN 62262) Connected or not |
Noise Level | < 40 dBA / 1m |
Product Standards | IEC 61851-1, IEC TS 61439-7 (AEVCS) |
Installation and Safety
Characteristic | Details |
---|---|
Installation | Indoors or outdoors, in a restricted-access zone, intended for use by ordinary persons (DBO), wall mounting, pollution degree 3, TNS, TT, compatible earthing system. With an IT earthing system, this can be locally modified by adding an isolation transformer. |
Electrical Safety | Class 1 IEC 61140 |
Electromagnetic Compatibility | |
European Standards | Low Voltage Directive 2014 / 35EU / EMC Directive: 2014 / 30 / EU |
Radio Technology Type | GSM 2G/3G/4G, GPRS, RFID |
Suitable Charging Cards | Mifare, Ntag and iCODE SLI cards |