Ecotap Duo Wide XL
A brand of Legrand
General Properties
Reference Number | 668062 / 65020010 / 65458063 |
---|---|
Reference Number (Calibration) | 65458062 |
Dimensions (H x W x D) | 1746 x 573 x 394 mm |
Housing Material | Steel 3.7 mm |
Standard Color | Housing: Ral 6018 / Cover: Ral 9016 for 668062 / 65458062 / 65458063 Housing: Ral 9016 / Cover: Ral 9016 for 65020010 |
Steel Treatment | Corrosion protection (KTL) and powder coating |
Weight | 85 kg |
Number of Charging Points | 2 |
Socket | Type 2 |
Cable | Type 2 |
Cable | Type 2 |
Electrical Properties
Output per Socket | 0 to 22 kW |
---|---|
Operating Voltage (Ue) / Rated Current (In A) for the charger | Single-phase connection, Phase + N 230V~ from 0 to 80A (specified at 20°C) Three-phase connection, 3 Phases + N 400V~ from 0 to 80A (specified at 20°C) |
Operating Voltage (Ue) / Rated Current (In A) per charging point | Single-phase connection, Phase + N 230V~ from 0 to 32A (specified at 20°C) Three-phase connection, 3 Phases + N 400V~ from 0 to 32A (specified at 20°C) |
Impulse Voltage (Uimp) | 4kV |
Insulation Voltage (Ui) | 230V single-phase, 500V three-phase |
Frequency (fn) | 50Hz/60Hz |
Nominal Voltage | 1 Phase + N: 230V - 3 Phases + N: 400V |
Voltage Tolerance (V) | 195V - 265V |
Integrated Protection System at Charging Station | Main fuse holder 50 A |
Integrated Protection System per Charging Point | Fuse holder 32A Gg, RCD 63A 30mA Type B |
Conditional Short-circuit | 6000A IEC/EN 60898-1, 10kA IEC/EN 60947-2 |
Admissible Thermal Load during Short Circuit | 16,000 A²s |
Connection to the Power Grid | Phase/Neutral, rigid cable, 2.5 to 35 mm², Screw terminals H07 V R/U Earth, rigid cable, 2.5 to 35mm², Screw terminals H07 V R/U |
Type of Charging | Mode 3 charging station with a locking system for Mode 3 |
Vehicle Connection Socket Mode 3 | Type 2 3P+N (single-phase compatible) with control devices according to IEC 62191-1 and IEC 62196-2. Use only a manufacturer-approved plug with silver-plated contacts. The use of extensions and adapters is prohibited. |
Phase Rotation on Channel 2 (right side) | In case of a single-phase connection (Ph+N) to the power source, Channel 2 cannot start charging until the phase rotation between the contactor and the socket is manually reversed. |
AC Meter | MID certified, Class B according to EN 50470-1, -3 |
Back-Office Protocol | OCPP 1.6 Json |
Positioning | GPS |
Ethernet Connectivity | 668062 / 65020010 / 65458062 |
Environment
Operating Temperature | -25°C / +50°C |
---|---|
Storage Temperature | -25°C / +80°C |
Relative Humidity | 0 to 90% without condensation |
Protection Class | IP 54 (IEC 60529), IK 10 (EN 62262) Plugged in or not |
Noise Level | < 40 dBA /1m |
Product Standards | IEC 61851-1, IEC TS 61439-7 (AEVCS) |
Installation | Indoor or outdoor area, zone with restricted access, intended for use by normal persons (DBO), installation in cabinet (wall mounting), pollution degree 3, TNS, TT, compatible earthing system. In case of an IT earthing system, this can be modified on-site by adding a separating transformer. |
Electrical Protection | Class 1 IEC 61140 |
Electrical Safety | Class 1 IEC 61140 |
Electromagnetic Compatibility
European Standards | Low Voltage Directive 2014 / 35EU / EMC Directive: 2014 / 30 / EU |
---|---|
Type of Radio Technology | GSM 2G/3G/4G, GPRS, RFID |
Suitable Charging Cards | Mifare, Ntag and iCODE SLI Card |