Bertazzoni Built-In Refrigerator Installation Guide
Product Dimensions
Side View
Overall Height: 80 3/4" (2050 mm) + 1" (25 mm)
Overall Width: 41 7/8" (1065 mm)
Overall Depth: 22 1/16" (560 mm)
Handle Dimension: 5" (127 mm)
Toe Kick Depth: 2 3/4" (70 mm)
Base Depth: 19 5/8" (500 mm)
Cabinet Depth: 5 3/4" (146 mm) + 1" (25 mm)
Front View
Overall Height: 83 1/2" (2120 mm) + 1" (25 mm)
Door Width: 29 5/8" (752 mm)
Upper Section Height: 54 1/4" (1378 mm)
Lower Section Height: 23 1/8" (587 mm)
Wall Clearance: 3/8" (9 mm)
Top View
Overall Depth: 29 15/16" (761 mm)
Overall Width: 7 5/8" (195 mm)
Handle Clearance: 105°
Cabinet Width: 52 3/8" (1331 mm)
Back Clearance: 24 3/16" (615 mm)
* Maximum Overall Handle Dimension
Cutout Dimensions
Front View
Cabinet Height: 83 7/8" (2130 mm) Min.
Cabinet Width: 30" (762 mm)
Clearance for anti-tipping brackets (a): 3"1/2x5" (82x127mm)
Top View
Cabinet Width: 25" (635 mm)
Electrical & Water Connection
Electrical Connection (E)
A properly-grounded, horizontally-mounted electrical receptacle should be installed according to the drawing.
Water Connection (W)
To connect to the water supply system, a 1/4" NPT waterline with accessible shut-off valve must be supplied.
Connection(s) placement within the opening may require additional cabinet depth.
A separate circuit breaker servicing only this appliance is recommended. For installation of multiple products in combination, refer to the Built-in Food Preservation Design Guide.
Dimensions in parentheses are millimeters unless otherwise specified.
Diagrams:
Top View Electrical & Water: Shows placement of E (Electrical) and W (Water) connections.
Front View Electrical & Water: Shows placement of E (Electrical) and W (Water) connections.
Installation Requirements
If the appliance(s) is not connected through the side profile trims to secured cabinetry anti-tip brackets must be installed.