Bertazzoni Built-In Freezer Installation Dimensions and Requirements
Product Dimensions
Detailed measurements for the Bertazzoni built-in freezer.
Side View
Illustrates the side profile of the appliance. Key dimensions:
- Overall height: 80 3/4 inches (2050 mm) + 1 inch (25 mm) clearance = 81 3/4 inches total.
- Depth: 19 5/8 inches (500 mm).
Front View
Shows the front profile of the appliance. Key dimensions:
- Overall height: 83 1/2 inches (2120 mm) + 1 inch (25 mm) clearance = 84 1/2 inches total.
- Door width: 17 5/8 inches (447 mm).
Top View
Depicts the top profile of the appliance. Key dimensions:
- Overall depth: 40 1/2 inches (1029 mm).
- Width: 24 3/16 inches (615 mm).
Cutout Dimensions
Specifications for the cabinet opening required for installation.
Side View
Illustrates the side view of the required cabinet cutout space. The appliance depth of 19 5/8 inches (500 mm) must fit within this space.
Front View
Shows the front view of the required cabinet cutout.
- Minimum height: 83 7/8 inches (2130 mm).
- Total width for the appliance: 25 inches (635 mm).
- Two sections labeled 'a' indicate areas to be left clear for anti-tipping brackets.
Top View
Depicts the top view of the required cabinet cutout. It shows the overall width requirement of 25 inches (635 mm) for the appliance. Specific areas must be left clear for the anti-tipping brackets: 3 1/2 inches x 5 inches (82x127mm).
Electrical & Water Connection
Requirements for connecting the appliance.
Connection Points
Diagrams show the placement of Electrical (E) and Water (W) connections.
- Top View: Labeled sections EW, E, W, EW.
- Front View: Labeled sections EW, E, W, EW. A vertical dimension of 5 inches (127 mm) is indicated for this area.
Electrical Requirements
A properly-grounded, horizontally-mounted electrical receptacle should be installed according to the drawing. A separate circuit breaker servicing only this appliance is recommended.
Water Supply Requirements
To connect to the water supply system, a 1/4" NPT waterline with an accessible shut-off valve must be supplied.
General Notes
Connection(s) placement within the opening may require additional cabinet depth. For installation of multiple products in combination, refer to the Built-in Food Preservation Design Guide. Dimensions in parentheses are millimeters unless otherwise specified.
Installation Requirements
If the appliance(s) is not connected through the side profile trims to secured cabinetry, anti-tip brackets must be installed.