Technical Specification for Schneider Electric models including: ATS480, ATS480 Altivar Soft Starter, ATS480, Altivar Soft Starter, UL60947-4-2, Soft Starter, Starter
ATS480 getting started annex for UL60947-4-2 User guide | Schneider Electric
File Info : application/pdf, 4 Pages, 377.09KB
DocumentDocumentANNEX Annex to the Getting Started with Altivar Soft Starter ATS480 for UL60947-4-2 ATS480Y Combination Short Circuit Current Ratings (SCCR) The combinations in the table below have been tested per UL60947-4-2. These ratings allow proper coordination of short circuit protection. All the ratings of the product have a 100kA interrupt rating at the output. The opening of the branch circuit protective device may be an indication that a fault current has been interrupted. Altivar Soft Starters are provided with integral overload monitoring and can provide motor overload protection at 100% of the full load motor current. The motor thermal current [Motor Nom Current] IN must be set to the rated current indicated on the motor nameplate. For more information refer to the ATS480 User Manual (NNZ85515). DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH · Current-carrying parts and other components of the controller should be examined and replaced if damaged. · If burnout of the current element of an overload relay occurs, the complete overload relay must be replaced. Failure to follow these instructions will result in death or serious injury. ATS480 Power ratings normal duty (HP) Catalog Number (b) 3 ATS480D17Y 5 ATS480D22Y 7,5 ATS480D32Y 10 ATS480D38Y - ATS480D47Y 15 ATS480D62Y 20 ATS480D75Y 25 ATS480D88Y 30 ATS480C11Y 40 ATS480C14Y 50 ATS480C17Y 60 ATS480C21Y 75 ATS480C25Y 100 ATS480C32Y 125 ATS480C41Y 150 ATS480C48Y - ATS480C59Y 200 ATS480C66Y 250 ATS480C79Y 350 ATS480M10Y 400 ATS480M12Y 5 ATS480D17Y 7,5 ATS480D22Y 10 ATS480D32Y - ATS480D38Y 15 ATS480D47Y 20 ATS480D62Y 25 ATS480D75Y 30 ATS480D88Y 40 ATS480C11Y 50 ATS480C14Y 60 ATS480C17Y 75 ATS480C21Y 100 ATS480C25Y 125 ATS480C32Y 150 ATS480C41Y - ATS480C48Y 200 ATS480C59Y 250 ATS480C66Y 350 ATS480C79Y 400 ATS480M10Y 450 ATS480M12Y Normal Duty SCCR Ratings (b) SCCR (X) (a) Fuses (c) Fuse rating Class (Z) (a) (kA) (A) 208Vac (Y) (a) 100 30 J 100 40 J 100 50 J 100 60 J 100 70 J 100 100 J 100 125 J 100 150 J 100 175 J 100 225 J 100 250 J 100 350 J 100 400 J 100 500 J 100 600 J 100 700 L 100 800 L 100 1000 L 100 1200 L 100 1500 L 100 1800 L 230Vac (Y) (a) 100 30 J 100 40 J 100 50 J 100 60 J 100 70 J 100 100 J 100 125 J 100 150 J 100 175 J 100 225 J 100 250 J 100 350 J 100 400 J 100 500 J 100 600 J 100 700 L 100 800 L 100 1000 L 100 1200 L 100 1500 L 100 1800 L TeSys Contactor (d) Recommended Catalog Number (d) Contactor SCCR (e) (LC1F/LC1G) (kA) LC1D25 LC1D25 LC1D32 LC1D38 LC1D50A LC1D65A LC1D80 LC1D115 LC1D115 LC1D150 LC1F/G185 LC1F/G225 LC1F/G265 LC1F/G330 LC1F/G400 LC1F/G500 LC1F630/G630 LC1F800/G630 LC1F/G800 - - 100 100 100 100 100 100 100 100 100 100 100 10 / 100 100 100 10 / 100 10 / 100 10 / 100 10 / 100 18 / 100 - - LC1D25 LC1D25 LC1D32 LC1D38 LC1D50A LC1D65A LC1D80 LC1D115 LC1D115 LC1D150 LC1F/G185 LC1F/G225 LC1F/G265 LC1F/G330 LC1F/G400 LC1F/G500 LC1F630/G630 LC1F800/G630 LC1F/G800 - - 100 100 100 100 100 100 100 100 100 100 100 10 / 100 100 100 10 / 100 10 / 100 10 / 100 10 / 100 18 / 100 - - www.se.com 1/4 NNZ86539.01 12/2021 ATS480 Power ratings normal duty (HP) Catalog Number (b) 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 500 600 800 1000 ATS480D17Y ATS480D22Y ATS480D32Y ATS480D38Y ATS480D47Y ATS480D62Y ATS480D75Y ATS480D88Y ATS480C11Y ATS480C14Y ATS480C17Y ATS480C21Y ATS480C25Y ATS480C32Y ATS480C41Y ATS480C48Y ATS480C59Y ATS480C66Y ATS480C79Y ATS480M10Y ATS480M12Y 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 500 600 800 1000 1200 ATS480D17Y ATS480D22Y ATS480D32Y ATS480D38Y ATS480D47Y ATS480D62Y ATS480D75Y ATS480D88Y ATS480C11Y ATS480C14Y ATS480C17Y ATS480C21Y ATS480C25Y ATS480C32Y ATS480C41Y ATS480C48Y ATS480C59Y ATS480C66Y ATS480C79Y ATS480M10Y ATS480M12Y Normal Duty SCCR Ratings (b) SCCR (X) (a) Fuses (c) Fuse rating Class (Z) (a) (kA) (A) 460Vac (Y) (a) 100 30 J 100 40 J 100 50 J 100 60 J 100 70 J 100 100 J 100 125 J 100 150 J 100 175 J 100 225 J 100 250 J 100 350 J 100 400 J 100 500 J 100 600 J 100 700 L 100 800 L 100 1000 L 100 1200 L 100 1500 L 100 1800 L 575Vac (Y) (a) 100 30 J 100 40 J 100 50 J 100 60 J 100 70 J 100 100 J 100 125 J 100 150 J 100 175 J 100 225 J 100 250 J 100 350 J 100 400 J 100 500 J 100 600 J 100 700 L 100 800 L 50 1000 L 50 1200 L 50 1500 L 50 1800 L TeSys Contactor (d) Recommended Catalog Number (d) Contactor SCCR (e) (LC1F/LC1G) (kA) LC1D25 LC1D25 LC1D32 LC1D38 LC1D50A LC1D65A LC1D80 LC1D115 LC1D115 LC1D150 LC1F/G185 LC1F/G225 LC1F/G265 LC1F/G330 LC1F/G400 LC1F/G500 LC1F630/G630 LC1F800/G630 LC1F/G800 - 100 100 100 100 100 100 100 100 100 100 100 10 / 100 100 100 10 / 100 10 / 100 10 / 100 10 / 100 18 / 100 - LC1D25 LC1D25 LC1D32 LC1D38 LC1D50A LC1D65A LC1D80 LC1D115 LC1D115 LC1D150 LC1F/G185 LC1F225/G265 LC1F265/G330 LC1F/G330 LC1F/G400 LC1F500/G400 LC1F/G630 LC1F/G800 LC1F/G800 - 100 100 100 100 100 100 100 100 100 100 100 100 100 100 18 / 100 18 / 100 30 / 100 30 /100 42 / 100 - (a) For devices subjected to standard fault short circuit test only, the short circuit current and voltage rating shall be marked, "Suitable For Use On A Circuit Capable Of Delivering Not More Than __X__ rms Symmetrical Amperes, __Y__ Volts Maximum". For devices subjected to high fault short circuit tests, the marking shall also include the following: · "When protected by __Z__ Class Fuses" (b) For all models, rating indicates standard use conditions. For heavy duty condition, the catalogue must be referred to. (c) Fused combination will require a UL Listed 98 or 508 Motor Circuit Switch or a UL 489 Molded Case switch. (d) Contactor may be LC1 or LC2 type. The next larger contactor may be substituted for the one shown. Contactors may be used in conjunction with circuit breaker protection and ATS480 soft starter for line and load isolation applications. (e) Short circuit ratings (kA) are based on the fuse class and ratings shown for the ATS480. www.se.com 2/4 NNZ86539.01 12/2021 Altivar (ATS···) Altivar (ATS···) . . , , . . . . . , , (), , . . . : , . , . . - , , , . , , . , . : , . , , . : « » : 127018, , . , . , .12, .1 . +7 (495) 777 99 90 +7 (495) 777 99 92 ( "Made in"): PPYYWW, PP , YY , WW . : « » -: , ., ., « » , 5- . .: +7 (727) 357 23 57 .: +7(727) 357 24 39 ( "Made in"): PPYYWW, PP - , YY - , WW . www.se.com 3/4 NNZ86539.01 12/2021 MANUFACTURER Schneider Electric Industries SAS 35 rue Joseph Monier Rueil Malmaison 92500 France UK REPRESENTATIVE Schneider Electric Limited Stafford Park 5 Telford, TF3 3BL United Kingdom China RoHS Hazardous Substances Table 20 The data shown in this spreadsheet are related to the following version of the China RoHS 2.0: "Administrative Measures for the Restriction of Hazardous Substances in Electric Appliances and Electronic Products" released January 21st 2016. Part Name Metal parts Plastic parts Electronic Contacts Cables & cabling accessories (Pb) X O X O O (Hg) O O O O O - Hazardous Substances (Cd) (Cr (VI)) O O O O O O O O O O (PBB) O O O O O (PBDE) O O O O O SJ/T11364 O: GB/T 26572 X: GB/T 26572 This table is made according to SJ/T 11364. O: indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below the limit as stipulated in GB/T 26572. X: indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part is above the limit as stipulated TTin GB/T 26572 www.se.com 4/4 NNZ86539.01 12/2021
![]() |
Altivar Soft Starter ATS480 User Manual - Schneider Electric Comprehensive user manual for the Schneider Electric Altivar Soft Starter ATS480, detailing installation, operation, safety, technical specifications, and troubleshooting for industrial applications. |
![]() |
Schneider Electric TeSys Deca LC1D25 Contactor - Technical Specifications and Data Detailed technical data sheet for the Schneider Electric TeSys Deca LC1D25 IEC contactor. Includes specifications for motor control, power ratings, electrical and mechanical durability, environmental data, and ordering information. |
![]() |
Schneider Electric LC1D/LC2D Series Contactors: Technical Specifications and Installation Guide Comprehensive guide to Schneider Electric's LC1D and LC2D series contactors, covering product specifications, safety warnings, installation procedures, dimensions, wiring, and accessories. Features detailed information for electrical engineers and technicians. |
![]() |
Schneider Electric Altistart 480 Soft Starter ATS480D88Y Technical Data Detailed technical specifications, dimensions, electrical characteristics, environmental data, and ordering information for the Schneider Electric Altistart 480 soft starter, model ATS480D88Y. |
![]() |
Schneider Electric TeSys K Contactor LC1K0601E7 - 6A, 48VAC Coil Technical data sheet for the Schneider Electric TeSys K Contactor LC1K0601E7. Features include 3 poles, 1 NC auxiliary contact, AC-3 utilization category up to 440V, and 48VAC coil. Details on specifications, dimensions, environment, ordering, and packing units. |
![]() |
Schneider Electric Altivar Soft Starter ATS480 DTM Library V1.1.10 Release Notes Release notes for Schneider Electric's Altivar Soft Starter ATS480 DTM Library V1.1.10, detailing features, package content, system requirements, and compatibility for industrial automation applications. |
![]() |
Schneider Electric Products for Industry and Trade - Conrad Discover special offers and new products from Schneider Electric for industry and trade, including TeSys Deca motor starters, Altivar frequency converters, PanelSeT enclosures, Harmony signal towers, Mureva distribution boards, Resi9 devices, and Asfora switches and sockets. Available at Conrad. |
![]() |
Schneider Electric REACH Compliance Information for GV5PB150S This document provides information regarding Substances of Very High Concern (SVHC) in Schneider Electric products, specifically the GV5PB150S motor circuit protector, in accordance with REACH regulation. |