Dear Customer,
Schneider Electric SE and its affiliates have undertaken since 2008 to comply strictly with the REACH regulation N° 1907/2006 for the declaration of Substances of Very High Concern (SVHC), authorization (Annex XIV) and restriction (Annex XVII).
As per our commitment under article 33 of the said regulation, we provide information regarding the presence of SVHC in Schneider Electric products, to the best of our knowledge and as of the date of publication. This information may evolve over time based on improved knowledge from suppliers and our investigations.
Schneider Electric has also considered the judgment of the EU Court of Justice of 10 September 2015 in case C-106/14 and is investigating the necessary actions for its implementation.
In line with its environmental strategy, Schneider Electric and its affiliates apply the REACH regulation on a worldwide basis.
Our company's Environment policy drives us to continuously work towards products and services that reduce environmental or human health impact during intended use and under conditions stated in documentation. Schneider Electric aims to substitute substances of concern, particularly REACH Annex XIV substances, before their sunset dates.
At the end of life of products, please follow appropriate waste and recycling procedures. If a product falls under RoHS legal scope, this document does not serve as a CE declaration. For CE declarations, please refer to the Customer Care Centers.
Best Regards,
Vanessa MILER-FELS
VP Environment
Product Information
Commercial reference: GV5PB150S
Range: TeSys GV5PB & GV6PB
Brand: Schneider Electric
Product description: Motor Circuit Protector 600V 150A
SCIP ID: No need to declare in the SCIP database
This product does not contain any substance under REACH annex XVII regulation in the scope of restriction, including asbestos and polycyclic-aromatic hydrocarbons (PAH).
According to REACH Regulation EC 1907/2006 article 33 and the EU Court of Justice judgment of 10 September 2015 (case C-106/14), the following SVHC are present in this product above the 0.1% threshold at the part level.
Our products are safe from a chemical exposure perspective under normal conditions of use. For specific safe conditions of use, please refer to the table below. For specific End of Life recommendations, please consult the Product End of Life instructions according to the WEEE document.
Part | SVHC content | CAS number | EC number | Specific Safe conditions of use |
---|---|---|---|---|
This product includes metallic part(s) that contain(s) the following substance(s) above the threshold at part level. | Lead | 7439-92-1 | 231-100-4 | None |
In this product, the PCBA includes electronic components that contain the following substance(s) above the threshold at component level. | Lead | 7439-92-1 | 231-100-4 | None |
In this product, the PCBA includes electronic components that contain the following substance(s) above the threshold at component level. | EGDME | 110-71-4 | 203-794-9 | None |
In this product, the PCBA includes electronic components that contain the following substance(s) above the threshold at component level. | PZT | 12626-81-2 | 235-727-4 | None |
In this product, the PCBA includes electronic components that contain the following substance(s) above the threshold at component level. | Benzene-1,2,4-tricarboxylic acid 1,2-anhydride (trimellitic anhydride TMA) | 552-30-7 | 209-008-0 | None |
Schneider Electric Industries SAS
Postal address / Adresse postale :
Le Hive
35 rue Joseph Monier - CS 30323
F-92506 Rueil Malmaison Cedex
Phone: +33 (0)4 76 57 60 60
http://www.schneider-electric.com
Legal information / Mentions légales :
Société par actions simplifiée au capital de 896,313,776 euros
954 503 439 rcs Nanterre - code APE : 2712Z
Siret: 954 503 439 01719
n°ident. TVA: FR 04 954 503 439
Siège Social! 35, rue Joseph Monier
F - 92500 Rueil-Malmaison