Ceiling&Floor Heat Pump System Submittal Data Sheet

General Information

Location:

Engineer:

Submitted to:

Submitted by:

Reference:

Approval:

Date:

Construction:

Unit #:

Drawing #:

Certified by ENERGY STAR, AHRI, and ETL.

Efficiency Ratings

CoolingHeating
SEER2EER2HSPF2-4COP
20.412.012.13.34

Performance Specifications

Cooling Performance

Cooling (Btu/hr)
Rated Capacity22000
Min/Max Capacity12700~25600
Moisture Removal (L/h)2.73
Standard Operating Range (°F/°C)-22~122 (-30~50)
ConditionsIndoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB

Heating Performance

Heating (Btu/hr)
1. @ 47°F Rated26000
1. @ 47°F Min/Max Capacity11300~29500
2. @ 17°F Rated20200
3. @ 5°F Rated: Capacity / COP24200/2.16
3. @ 5°F Max: Capacity24200
Standard Operating Range (°F/°C)-22~75 (-30~24)
Conditions1. Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
2. Indoor: 70°F DB/60°F WB
Outdoor: 17°F DB/15°F WB
3. Indoor: 70°F DB/60°F WB
Outdoor: 5°F DB/5°F WB

Indoor Unit Specifications

Indoor Air Flow (Turbo/H/M/L/SI) (CFM)735.8 / 706.3 / 606.3 / 453.2 / 376.7
Indoor Noise Level (Turbo/H/M/L/SI) (dBA)51.5 / 49.0 / 45.0 / 34.0 / 29.0
Dimension (W×D×H)42.05 x 26.57 x 9.25 inches
1068.0×675.0×235.0 mm
Package (W×D×H)45.08 x 29.72 x 12.52 inches
1145×755×318 mm
Net/Gross Weight61.29/73.19 lbs
27.8/33.2 kg

Outdoor Unit Specifications

Compressor TypeROTARY
Compressor ModelKTM240D46UKT2
RefrigerantR454B
Refrigerant Oil Charge (mL)620
Refrigerant OilVG74
Outdoor Air Flow (Max) (CFM)2236.7
Outdoor Noise Level (dBA)61.5
Dimension (W×D×H)37.24 x 16.14 x 31.89 inches
946.0×410.0×810.0 mm
Package (W×D×H)42.91 x 19.68 x 34.84 inches
1090×500×885 mm
Net/Gross Weight130.29/141.31 lbs
59.1/64.1 kg

Electrical Specifications

Power Supply208/230V, 60Hz, 1Ph
System MCA24.90
Connection Wiring14#x4
System MOCP25
Compressor RLA15.0
Outdoor Fan Motor RLA1.3
Outdoor Fan Motor W120
Indoor Fan Motor RLA1.0
Indoor Fan Motor W90
System Power Input @ Cooling (W)1833 (980~2300)
System Power Input @ Heating (W)2194 (630~2570)
MCA: Min. circuit amps (A)
MOCP: Max. over current protection (A)
RLA: Rated load amps (A)
W: Fan motor rated output (W)

Piping Specifications

Throttle type (Indoor)N/A
Throttle type (Outdoor)EXV+Throttle valve
Liquid Size9.52mm (3/8in)
Gas Size15.9mm (5/8in)
Max. Piping Length (ft/m)164.00 (50)
Max. Height Difference (ft/m)82.00 (25)
Max. Pre-charged Length (ft/m)24.6 (7.5)
Refrigerant Pre-charged Amount (oz/kg)63.49 (1.80)
Additional Charge of Refrigerant ((oz/ft)/(g/m))0.32 (30)
Connection MethodFlared

Indoor Unit Dimensions and Installation

The indoor unit is shown from front, side, and top views. Key features and dimensions are labeled. These include a drain discharge port (1-1/2in / 40mm), fresh air intake (4-3/4in / 120mm), wiring connection port (1-1/8in / 33mm), and refrigerant pipe hole. A hanging arm is also indicated.

A table provides dimensions A, B, C, and D for different models: 18K/24K and 36K/48K/60K. For 18K/24K: A=42in(1068mm), B=26-1/2in(675mm), C=9-1/4in(235mm), D=38-3/4in(983mm). For 36K/48K/60K: A=65in(1650mm), B=26-1/2in(675mm), C=9-1/4in(235mm), D=61-5/8in(1565mm).

The installation diagram for the indoor unit indicates required clearances. A minimum of 1.38 inches (35mm) is required from the top and sides of the unit. A minimum of 38.4 inches (1000mm) is required from the front.

Outdoor Unit Dimensions and Installation

The outdoor unit is depicted from front, side, and top views. Various dimensions and connection points are labeled, including refrigerant pipe connections, electrical connections, and mounting points.

The installation diagram for the outdoor unit specifies clearance requirements. A minimum of 20 inches (500mm) is required when the front and sides of the unit are clear. A minimum of 4 inches (100mm) is required from the sides. A minimum of 14 inches (350mm) is required from the rear. If any two sides (left, right, and rear) of the unit are clear, a minimum of 20 inches (500mm) is required from those sides. A checkmark icon ✔️ confirms that all spatial requirements shown in the installation clearance requirements are met.

Features

  • 2 Style Installation
  • 3D Airflow
  • Refrigerant leakage detection sensor
  • Humidity sensor
  • "88" display tube
  • 1~100% fan speed setting
  • WiFi capability: through WiFi dongle or wired controller with built-in WiFi
  • OTA (by using WiFi dongle)
  • 2-pin connector (HA/HB) for programmable wired controller
  • Multiple control options available:
    • Two way communication wired controller: 120N(X6)
    • Two way communication wired controller with built-in WiFi: 120N(X6W)
    • Infrared wired controller: 120L
    • Wireless remote controller
    • Third-Party 24V Thermostat*
  • *24V interface is required.

PDF preview unavailable. Download the PDF instead.

blueridgebxs5a24uc0-24fc0specificationssheet DD45F967-50F6-4F3D-BA10-99FE66E5A16E Google Sheets

Related Documents

Preview Blue Ridge 4-Way Cassette Heat Pump System: Submittal Data Sheet, Specifications, and Installation
Comprehensive submittal data sheet for the Blue Ridge 4-Way Cassette Heat Pump System (Model EKPQ420D1UMUA). Includes detailed efficiency ratings, cooling and heating performance, indoor and outdoor unit specifications, electrical and piping data, dimensional drawings, and installation clearance requirements.
Preview Blue Ridge XS5 CDH High Static Slim Duct Hyper Heat Series Submittal Data Sheet
Submittal data sheet for the Blue Ridge XS5 CDH High Static Slim Duct Hyper Heat Series heat pump system, detailing efficiency ratings, cooling and heating performance, indoor and outdoor specifications, electrical requirements, piping details, installation guidelines, and fan performance.
Preview Blue Ridge XL1 FC R454B Ceiling & Floor Regular System Submittal Data Sheet
Technical specifications, performance data, electrical details, and dimensions for the Blue Ridge XL1 FC R454B Ceiling & Floor Regular System air conditioning units (models 36K, 48K, 60K). Includes efficiency ratings, cooling and heating performance, electrical requirements, piping specifications, and unit dimensions.
Preview Blue Ridge Slim Duct Heat Pump System: Submittal Data Sheet & Specifications
Detailed submittal data sheet for the Blue Ridge Slim Duct Heat Pump System, including specifications, performance data, dimensions, and installation clearances. Features R454B refrigerant and Energy Star certification.
Preview Blue Ridge XL1 FC Ceiling & Floor Regular Series Air Conditioner Submittal Data
Submittal data sheet for the Blue Ridge XL1 FC Ceiling & Floor Regular Series air conditioner, detailing efficiency, performance, dimensions, electrical specifications, and features for models 36K-60K.
Preview Ceiling & Floor Heat Pump System Submittal Data Sheet
Submittal data sheet for the Ceiling & Floor Heat Pump System, detailing efficiency, performance, indoor and outdoor specifications, electrical, and piping information. Includes features and installation clearance requirements.
Preview Blueridge XS5 CC 4-Way Cassette Heat Pump System Submittal Data Sheet
Comprehensive submittal data sheet for the Blueridge XS5 CC 4-Way Cassette Heat Pump System, featuring R454B refrigerant. Includes detailed specifications, performance data for cooling and heating, electrical requirements, piping information, and installation clearance guidelines.
Preview Blue Ridge One Way Cassette Heat Pump System - Submittal Data Sheet & Specifications
Detailed submittal data sheet for the Blue Ridge One Way Cassette Heat Pump System, including efficiency ratings, performance data, electrical specifications, dimensions, installation clearances, and features. Model KSK103D33UEZ3, R454B refrigerant.